Electrical and Electronic Properties Measuring and Testing Instruments: PD86MMTRBCID0013, PD87MMTRB616, PD87MMTRBCID59

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
PD86MMTRBCID0013 6625-01-236-4776Meter, Power FactorCircuit Current for Which Designed: DC
Measurement Range: +0.0/+18.0 gigahertz single indicator 1ST range
Features Provided: Portable
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD86MMTRB CID#25
PD86MMTRBCID25
6625-01-248-6748Generator, SignalSpecial Features: Solid state; power consumption 450 va; tilt-bail handle; 0-50 deg C operating temp; mtbf 2, 000 hrs; digital sweep; 2 sets of oper manuals
Overall Length: 24.000 inches nominal
Overall Width: 17.000 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD86MMTRB CID#27
PD86MMTRBCID27
6625-01-248-6749Generator, SignalSpecial Features: Power consumption 450 va; tilt-bail handle; 2, 000 mtbf
Overall Length: 24.000 inches nominal
Overall Width: 17.000 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD86MMTRB CID#52
PD86MMTRBCID52
6625-01-245-5132Analyzer, Digital Data, ElectronicOverall Width: 36.200 inches nominal
Overall Height: 15.700 inches nominal
Indicator Type: Cathode ray tube
Warner Robins Air Logistics Center (98752)

Quote

PD86MMTRCID56 6625-01-317-4850Test set, Electronic SystemsFrequency Rating: 50.0 hertz minimum and 63.0 hertz maximum
Phase: Single
AC Voltage Rating: 100.0 volts minimum and 240.0 volts maximum
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD86MMTRDC6625CID 6625-01-235-1110Generator, SignalSpecial Features: 100, 120, 220, 240VAC; thermal switch; exterior fuze access; surge and transient voltage protection; operating temp 0 deg C to 5O deg c; storage temp minus 40 deg C to plus 70 deg c; manual, automatic, single sweep mode; 2 complete sets operation, instruction and programming manuals
Frequency Range Rating: +2.0/+26.0 gigahertz
Mounting Type: RACK
SAN Antonio Air Logistics Center (98750)

Quote

PD86MMTRDCCID001 6625-01-237-5986Test set, NavigationTest Type for Which Designed: Functional
Inclosure Feature: Single item W/housing
Functional Description: Used to test tacan receiver-transmitters
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD86MMTRDCCID0040 6625-01-241-5276OscilloscopeOverall Width: 13.400 inches nominal
Overall Height: 13.600 inches nominal
Frequency Rating: 50.0 hertz minimum and 400.0 hertz maximum
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD-87-MME-600
PD87MME600
6625-01-260-8209Test Bench set, Radar setEnd Item Identification: RF-4C acft age.
Test Type for Which Designed: Demonstrate operational assurance of the uut and guarantee fault isolation for failed units
Inclosure Feature: Multiple item W/housing
SAN Antonio Air Logistics Center (98750)

Quote

PD-87-MMTD-0060
PD87MMTD0060
6625-00-450-2066VoltmeterInstallation Design: Panel
Circuit Attachment Method and Quantity: 2 solder stud
Accuracy in Percent: -3.0/+3.0 at full scale single indicator all ranges
SAN Antonio Air Logistics Center (98750)

Quote

PD-87-MMTD-0067
PD87MMTD0067
6625-01-406-3706Analyzer, Digital Data, ElectronicSpecial Features: Minimum 32 data channel inputs; operates from internal (asynchronously to events in uut) and external (synchronous) clocks; 2 clock qualifier inputs which can be logically combined to qualify data acquisition in synchro operation; data inputs samples asynchronously at 100 mega samples per sec and synchronously at up to 25 mega samples per sec; crt display; logic threshold selection accuracy greater than porm 5PCT of threshold porm 5 pct of total variable voltage range; minimum data set up time less than 12 nsec before active clock transition; minimum data hold time less than 2 nsec; wide range microprocessor and bus support options; integrated state/timing trigger resources; glitch capture down to 3 nsecs; simultaneous 200 mhz TIMING/50 mhz state on all channels; includes probes, leads, power cord, & operation manuals
Overall Length: 17.000 inches nominal
Overall Width: 15.000 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRB0083 6625-01-271-5523Generator, SweepOverall Length: 20.000 inches nominal
Overall Width: 18.000 inches nominal
Overall Height: 7.000 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRB102 6625-01-267-2398Generator, Function, Electronic TeOverall Length: 12.000 inches nominal
Overall Width: 12.000 inches nominal
Overall Height: 4.000 inches nominal
SAN Antonio Air Logistics Center (98750)

Quote

PD87MMTRB616 6625-01-270-2306Reflectometer, Metallic Time DomaSpecial Features: Single phase; single item W/housing; carrying handle; accessories include: 1-50 ohm precision termination, 1-TESTER cable slide rule, 1-REPLACEMENT fuse, 2-OPERATOR'S manuals, 1-PRECISION 50 ohm cable (9 ft long), 1-BNC female-to-female adapter; operating test capability, P6/M18 db, 0/25000 ft, 2/25000 ft; electrical power source relationship, oerating; wattagerating 25 watts; crt or lcd display; recorder output; tilt bail handle; battery; storage temperature M20 to P55 deg c; weighs 18 lbs;maximum hz 410
Overall Length: 16.500 inches nominal
Overall Width: 12.400 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRB617 6625-01-270-0516Test set, Electrical meterSpecial Features: Operating temperature 0 to 50 degrees C., switch selectable scales, +/- 0.1 accuracy, low noise, IEEE-488 interface
Phase: Single
AC Voltage Rating: 115.0 volts nominal or 110.0 volts nominal or 100.0 volts nominal or 120.0 volts nominal or 230.0 volts nominal or 220.0 volts nominal or 200.0 volts nominal or 240.0 volts nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRB71 6625-01-266-5934Generator, PulseCircuit Construction Type: Solid state
Frequency per Channel: 0.000005 megahertz minimum operating channel and 50.000000 megahertz maximum operating channel
Output Wave Shape: Pulse, gate
SAN Antonio Air Logistics Center (98750)

Quote

PD87MMTRB96 6625-01-269-5438MultimeterOverall Length: 17.000 inches nominal
Overall Width: 15.000 inches nominal
Installation Design: Bench
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRB97 6625-01-269-4946Generator, SignalOverall Length: 20.000 inches nominal
Overall Width: 18.000 inches nominal
Overall Height: 8.000 inches nominal
SAN Antonio Air Logistics Center (98750)

Quote

PD87MMTRB97 6625-01-302-2712Generator, SignalFrequency Rating: 50.0 hertz minimum and 400.0 hertz maximum
Current Type: AC
Voltage Rating: 100.0 volts minimum and 240.0 volts maximum
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRBCID35 6625-01-257-5261Analyzer, NetworkOverall Length: 20.000 inches nominal
Overall Width: 19.500 inches nominal
Overall Height: 8.000 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD87MMTRBCID59 6625-01-252-3596OscilloscopeSpecial Features: Portable; 100 mhz; digital storage; bnc female connectors; IEEE-488; 0.2 div marking vertical and horizontal;trace rotation; 2 vertical amp channels; 50-100 mhz bandwidth; variable deflection control; accessories: 2 manuals, 2 10:1 V divider probes, one 1:1 V divider probe; probe tip kit for ea, fuses, pouch, 6 ft power code 2 om
Overall Width: 16.750 inches nominal
Overall Height: 7.500 inches nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote