Electrical and Electronic Properties Measuring and Testing Instruments: PD04WRLEEC37, PD07CBSSSGBEC31, PD07WRGBTRND20

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
PD04WRLEEC37 6625-01-413-0122Test set, Transmission lineFrequency Rating: 60.0 hertz minimum and 400.0 hertz maximum
Phase: Single
AC Voltage Rating: 110.0 volts nominal or 220.0 volts nominal
Warner Robins Air Logistics Center (98752)

Quote

PD04WRLEEC38 6625-01-522-3413Test set, Power SupplySpecial Features: Maximum limits: over voltage LIMIT-150V max; overcurrent LIMIT-60 amps max; overpower LIMIT-3000 watts max
Frequency Rating: 0.5 kilohertz minimum and 5.0 kilohertz maximum
Test Type for Which Designed: High power electronic load
Warner Robins Air Logistics Center (98752)

Quote

PD04WRLEEC53 6625-01-529-6724OscilloscopeFrequency Rating: 60.0 hertz nominal and 50.0 hertz nominal and 400.0 hertz nominal
Phase: Single
Current Type: Ac and dc
Warner Robins Air Logistics Center (98752)

Quote

PD04WRLEEC63 6625-01-535-3215Generator, SignalSpecial Features: Shall be class 3 iaw MIL-PRF-28800;SHALL not fail W/I 4, 000 hours of operation W/ 95 percent certainty; frequency resolution of less than or equal to 0.1HZ; output resolution 0.02DB or better; am deoth at least 0 to 90 percent; total weight shall not exceed 74 lbs.
Phase: Single
Current Type: AC

Quote

PD04WRLEEC66 6625-01-527-2770Counter, Electronic, Digital ReadoSpecial Features: Iaw MIL-PRF-28800;MTBF 4, 000 hours min; sensitivity -20DBM(BAND 1), and .95 - 2GHZ of -20DBM, 2-12.4 ghz of -25DBM, 12.4-20 ghz of -20 dbm, and 20-26.5 ghz of -15DBM(BAND 2), and -20DBM(BAND 3);NOMINAL input impedance 50 ohms; max input signal magnitude of +7 dbm(band 1 and 2); damage level shall have a max. input signal magnitude of +27DBM(BAND 1) and +45DBM cw and +53DBM peak pulsed (band 2); amplitude discrimination of 15DBM(BAND 1) and 15DBM(>50MHZ seperation(band 2)); frequency counter must reject signals of >50MHZ outside of the specified frequency limits (does not apply to band 1 or 3 W/frequency extension option); counter shall have ability to measure fm signals that remain in band on (band 1)AND 20MHZ P-P on (band 2)
Overall Width: 16.750 inches maximum
Overall Height: 3.500 inches maximum
Warner Robins Air Logistics Center (98752)

Quote

PD04WRLEEG41 6625-01-524-3180Test set, Electrical PowerSpecial Features: 9PORTABLE test set can be towed; includes meters for monitoring voltage, current and frequency; phase selector switch, phase rotation indicator, E-F pin indicator, cooling fans and air flow failure protection, load elements protections and disconnect
Frequency Rating: 60.0 hertz minimum and 400.0 hertz maximum
Phase: Single/three
Warner Robins Air Logistics Center (98752)

Quote

PD04WRLEEV26 MET L/W-4
PD04WRLEEV26METLW4
6625-01-557-7510Meter, Special ScaleSpecial Features: Meter shall be capable of transmitting data to the measurement device in U.S. gallons and shall be rated at 150 psig, shall include a 4INCH cam-lock coupler to 6INCH adaptor, shall be weasily transported and installed by one person
End Item Identification: Tactical automated tank gauging (tatg)
Part Name Assigned BY Controlling Agency: Tank meter
Warner Robins Air Logistics Center (98752)

Quote

PD04WRLEEV26 MET L/W-6
PD04WRLEEV26METLW6
6625-01-557-8111Meter, Special ScaleSpecial Features: Meter shall be capable of transmitting data to the measurement device in U.S. gallons and shall be rated at 150 psig, shall include a 6INCH cam-lock coupler to 4INCH adaptor, shall be weasily transported and installed by one person
End Item Identification: Tactical automated tank gauging (tatg)
Part Name Assigned BY Controlling Agency: Tank meter
Warner Robins Air Logistics Center (98752)

Quote

PD05WRGBTRND17 6625-01-296-2463Analyzer, Digital Data, ElectronicSpecial Features: Wrackmount capability, tilt-bail handle, accessory pouch; temp rqmts: M40.0/P65.0 deg. C. porm 5.0 deg. C. non-operating; P5.0/P45.0 deg. C. porm 5.0 deg. C. operating; humidity: non-condensing-porm 5.0 pct.; mtbf: 3000 hrs;automatic self-test capability; 32 remote terminal supportability; can allow unique and pre-defined test sequences; fault detection and storage; magnetic storage for on line read/write of stimulation data, test programs or captured bus messages; portable/benchtop
Overall Width: 19.000 inches nominal
Overall Height: 8.000 inches nominal
Warner Robins Air Logistics Center (98752)

Quote

PD05WRGBTRND19 6625-01-533-3103Resistor, DecadeSpecial Features: Shall be class 4 iaw MIL-PRF-28800; must not fail W/I 2000 hours ar 95 percent statistical certainity; ratio range 0 to 1.0 of input for 1.0 terminal and 0 to 1.1 for 1.1 terminal; resolution of .1PPM W/7 decades; max voltage input 1000V on 1.0 input terminal and 1100V on 1.1 input terminal; max input power 10 watts on 1.0 terminal and 11 watts on 1.1 terminal
End Item Identification: Automatic test equipment
Part Name Assigned BY Controlling Agency: Voltage divider
Warner Robins Air Logistics Center (98752)

Quote

PD05WRGBTRND21 6625-00-416-0152Test set, NavigationSpecial Features: Assigned name: test set, tacticalanalyzer
End Item Identification: Electronic test equip
Test Type for Which Designed: Range and bearing accuracy, sensitivity, peak power output
Warner Robins Air Logistics Center (98752)

Quote

PD05WRGBTRND26 6625-01-539-7230VoltmeterCircuit Current for Which Designed: AC
Overall Height: 1.750 inches nominal
Frequency Rating: 50.0 hertz minimum and 60.0 hertz maximum
Warner Robins Air Logistics Center (98752)

Quote

PD06WRGBTRND15 6625-01-538-7026Resistance StandardPart Name Assigned BY Controlling Agency: High resistance transfer standard
Functional Description: To provide highly accurate resistance values from 100 ohm to 110 megohm
Warner Robins Air Logistics Center (98752)

Quote

PD06WRGBTRND27 6625-01-545-5807Analyzer, Video IntegratingSpecial Features: Minimum frequency range 300KHZ to 6GHZ, will conform to class 4 equipment in accordance with MIL-PRF-28800, will be compatible with mounting in an ANSI/EIA-310-D standard equipment rack utilizing 5 standard height units, connectors will be on the front panel, display will be one or four channel color as a minimum and will be capable of displaying a different S-parameter in each of the four channels, will also be capable of displaying a different graph type for each channel, will include calibration/verification kits; test port adapters; test port cables; manuals(operator, maintenance, illustrated parts breakdown and calibration); IEEE488.2 or RS-232C or usb or 10/100BASET printer and remote interfaces
Overall Width: 17.810 inches maximum
Overall Height: 8.750 inches maximum
Warner Robins Air Logistics Center (98752)

Quote

PD06WRGBTRND39 6625-01-503-3795Analyzer, SpectrumFrequency Rating: 50.0 hertz minimum and 100.0 kilohertz minimum
Phase: Single
AC Voltage Rating: 110.0 volts nominal
Warner Robins Air Logistics Center (98752)

Quote

PD06WRGBTRND42 6625-01-502-8627Meter, Field StrengthInstallation Design: Hand held
Circuit Current for Which Designed: Ac and dc
Indicator Type: Digital display
Warner Robins Air Logistics Center (98752)

Quote

PD07CBSSSGBEC31 6625-01-551-9111Meter, Noise LevelSpecial Features: Noise figure meter with the following requirements: freq range 10MHZ to 40GHZ, enr calibration range 14.0DB to 16.5DB, dynamic range at least 0.0DB to 33.0DB, minimum bandwidth 4MHZ, accuracy PORM.10DB (0 to 9DB) PORM.20DB (9 to 12DB) porm .4DB (12 to 18DB) porm .75DB (18 to 21DB) porm 1DB (21 to 33DB), sensitivity at least -76DBM, input frequency at least 30MHZ, shall be compatible with ansi EIA-310-D standard equipment rack with 5 standard height units, weight will not exceed 40LBS, will be delivered with the following manuals: operator; maintenance and service; illustrated parts; and calibration, this item is class 3 iaw MIL-PRF-28800 except as specified within the purchase description
Installation Design: RACK
Test Data Document: B97566-IEEE std 488.2-1992 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). and A81349-MIL-PRF-28800F specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.). and C80204-ANSI EIA-310-D specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).
Warner Robins Air Logistics Center (98752)

Quote

PD07CBSSSGBEC32 6625-01-521-8463Resistance StandardSpecial Features: Power 120 vac +/- 10%, 60HZ +/- 3%; weight 300 lbs.; rack is required for this system; operating temp. 22.8DEGREES C, +/- 3.3 degrees c; complete set of interface cables included; 200 feet of shielded soild copper wire suitable for making standard 4 wire, low noise, low thermal, resistance measurements; process controller shall be a minimum of 200MHZ intel pentium, 32MB memory, 1GB hard drive and 17" monitor;compliance voltage +/- 30 volts; total measurement/uncertainity, resistance range 0.1 to 100M, uncertainity <1 to <25, test current range 10MICROAMP to 150 milli-amp continuously variable
Overall Length: 72.000 inches nominal
Overall Width: 36.000 inches nominal
Warner Robins Air Logistics Center (98752)

Quote

PD07WRGBGBEC37 6625-01-521-7873Test set, SynchroAC Voltage Rating: 100.0 volts nominal or 120.0 volts nominal or 220.0 volts nominal or 240.0 volts nominal
Frequency Rating: 50.0 hertz minimum and 60.0 hertz maximum
Test Type for Which Designed: Low distortion phase standard
Warner Robins Air Logistics Center (98752)

Quote

PD07WRGBTRND20 6625-01-548-3085Calibrator set, FrequencySpecial Features: Will include noise generators with type N and 3.5 mm connectors, computer with the folloing minimum requirements, 1GHZ pentium four processor, 20GIG hard drive, 128MB of ram, windows 2000 or higher operating system, IEEE488 controller card, ethernet card, 17 inch monitor, and laser printer, controller card, lan card, operating system will be pre installed, frequency range will be 10MHZ to 18GHZ (type n), 10MHZ to 26.5GHZ (3.5MM), power requirements will be 110V rms or 220V rms plus or minus 10 percent, freq requirements will be 50HZ and 60HZ plus or minus 6 percent, warm up period will not exceed 60 minutes, each unit will not EXCEED50 pounds, all units combined will not exceed 200 pounds
End Item Identification: Automatic test equipment
Component Document Origin: Government
Warner Robins Air Logistics Center (98752)

Quote

  • We solve sourcing challenges for PD04WRLEEC37, PD04WRLEEC38, PD04WRLEEC53, PD04WRLEEC63, PD04WRLEEG41, PD05WRGBTRND17, PD05WRGBTRND26, PD06WRGBTRND42, PD07CBSSSGBEC32, PD07WRGBTRND20 - NSN parts, hard to find, long lead time and obsolete components.