Pressure, Temperature, and Humidity Measuring and Controlling Instruments: OILTEMPERATURERSYSTEM/OPTIONS, ORC-26-350, OSK2K2816

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
OILTEMPERATURERSYSTEM/OPTIONS
OILTEMPERATURERSYSTEMOPTIONS
6685-01-503-1087Gage, Pressure, Dial IndicatingJP Instruments (1WGJ6)

Quote

OM-272-ALM
OM272ALM
6685-01-249-7991Recorder, TemperatureSpecial Features: Displays degrees F. per 12 hour increments, displays time, date and temperature for up to 12 location; 12 platinum rtds
Current Type: AC
Frequency Rating: 60.0 hertz nominal
Omega Engineering Inc. (29907)

Quote

OM-354 FIG 7-1 MKGS TP3
OM354FIG71MKGSTP3
6685-01-438-8999Thermostat, Flow ControlEND Item Identification: Iwo jima class lph;welder
Special Features: Opens at 80 deg;closes at 50 deg
Miller Electric Mfg Co. (40608)

Quote

OM-5140
OM5140
6685-01-383-2786Control, Temperature, RecordingSpecial Features: Automatically measures, monitors, and records temperatures and VOLTAGES;40 channels benchtop;can be keyboard programed or from A remote computer; built-in 24 character printer;graphic analysis software for pc via RS-232; hi and lo alarm relays; external print trigger and 14.5 K byte buffer memory, thermocouple inputs J, K, T, E, R, S, B, and rtds, 16 digit display, includes 83 in. paper roll, program functions date, time, print interval, content and format, channel configuration by type sensor, channels scaned or skipped, dwell time, engineering units, default and will print most functions. eng. units C. F. V. mv. A. ma. P. psi. ph. ms. vs. lbs. kg. G. ton. US2.
Operating Temp Range: +32.0/+122.0 deg fahrenheit
Phase: Single
Omega Engineering Inc. (29907)

Quote

OMEGA 6132-H
OMEGA6132H
6685-01-541-3722Sensor, Ambient TemperatureReference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications
Criticality Code Justification: ZZZY
Omega Engineering Inc. (29907)

Quote

OMEGASCOPE 2000
OMEGASCOPE2000
6685-01-136-5440Pyrometer, OpticalSpecial Features: Accuracy +/- 1 percent reading; standard 9 vdc battery; display resolution 0.1 degree; emissifity 0.10 to 1.00 in 0.01 increments; ambient operating temp 32 to 120 deg f; response time 250 msec; 4 digit liquid crystal display; selectable switching from deg F to deg c; temp range -20 to +2500 deg F and -30 to 1400 deg c; distance to size ratio 30:1; weight 2.0 lbs; out of rannge indication 8888 displayed
Overall Diameter: 3.000 inches nominal
Overall Depth: 6.500 inches nominal
Omega Engineering Inc. (29907)

Quote

OMNI-CAL-4A
OMNICAL4A
6685-01-187-4083Tester, Pyrometer and ThermocouplSpecial Features: Ithermocouple calibrator; weight 9.5 lbs; rechargeable internal nickel cadmium battery pack; 7 digit, 7 segment display; range depends on sensor used, can be from -422 to +2501 deg f; resolution 0.1 deg
Overall Diameter: 6.000 inches nominal
Overall Length: 12.250 inches nominal
Omega Engineering Inc. (29907)

Quote

OMNI-CAL8A
OMNICAL8A
6685-01-179-1826Tester, Pyrometer and ThermocouplScale Type: Meter dial
Scale Range: -418.0/+2500.0 degrees
Special Features: Consists of an 8 channel selectorwhich measures or outputs the proper current to test and calibrate J, K, T, E, R, S, and C thermocouples and meters as well as millivalt circuits;an offposition, T/C measure, output, and self-test sw, coarse and fine adjust knob;a abd B channel thermocouple sockets for comparison readings to A master;self tests for low battery, temperature, overrange, neg. temperature, open thermocouple, input, and input error;input voltage 110 vac 47 to 400 hz
Omega Engineering Inc. (29907)

Quote

ONE 6685-01-060-6139Temperature Measuring SystemGeneral Characteristics Item Description: 4-WIRE sensor, measurement range M50 to P50 deg C, ambient temp accuracy porm 0.1 deg C, difference temp accuracy porm 0.06 deg c; 103.5-126.5 vac, 50-60 hz, 200 w; front panel 4 1/2 digit display; rack mount chassis W/slides and handles; ambient temp range 0-70 deg C
Environmental Systems Corp. (56734)

Quote

OPA3000000-0
OPA30000000
6685-01-611-6412Hygrothermometer, DigitalEND Item Identification: Lantirn test station
GE Infrastructure Sensing Inc. (27970)
General Eastern Instruments Inc. (51088)

Quote

OPT-CY16
OPTCY16
6685-01-506-9391Control, Temperature, IndicatingCase Material: Metal
Mounting Method: Panel
Power Source: External
Athena Controls Inc. (61166)

Quote

ORC-26-220
ORC26220
6685-01-532-4085Transmitter, Temperature, ElectricEnd Item Identification: Engine, diesel mdl M0256K43
Style Designator: Transmitter, 24V dc
Holyhead Marine Services LTD (KC050)

Quote

ORC-26-340
ORC26340
6685-01-532-4085Transmitter, Temperature, ElectricEnd Item Identification: Engine, diesel mdl M0256K43
Style Designator: Transmitter, 24V dc
Holyhead Marine Services LTD (KC050)

Quote

ORC-26-350
ORC26350
6685-01-532-4150Thermostat, Flow ControlEnd Item Identification: Engine, diesel mdl M0256K43
Holyhead Marine Services LTD (KC050)

Quote

ORS37 6685-01-255-4039Gage, Pressure, Dial IndicatingScale Type: Concentric arc dial
Scale Range: +0.0/+35.0 pounds pressure per square inch
Scale Name: Differential pressure
Orange Research Inc. (30839)

Quote

OS101-MA
OS101MA
6685-01-534-7192Transmitter, Temperature, ElectricOperating Temp Range: -18.0/+538.0 deg celsius
Unit Type: Shielded
Accommodated Contact Type and Quantity: 2 screw
Omega Engineering Inc. (29907)

Quote

OS101-MA-SS
OS101MASS
6685-01-534-7192Transmitter, Temperature, ElectricOperating Temp Range: -18.0/+538.0 deg celsius
Unit Type: Shielded
Accommodated Contact Type and Quantity: 2 screw
Omega Engineering Inc. (29907)

Quote

OS-2101
OS2101
6685-01-136-5440Pyrometer, OpticalSpecial Features: Accuracy +/- 1 percent reading; standard 9 vdc battery; display resolution 0.1 degree; emissifity 0.10 to 1.00 in 0.01 increments; ambient operating temp 32 to 120 deg f; response time 250 msec; 4 digit liquid crystal display; selectable switching from deg F to deg c; temp range -20 to +2500 deg F and -30 to 1400 deg c; distance to size ratio 30:1; weight 2.0 lbs; out of rannge indication 8888 displayed
Overall Diameter: 3.000 inches nominal
Overall Depth: 6.500 inches nominal
Omega Engineering Inc. (29907)

Quote

OS540 6685-01-531-7291Thermometer, InfraredSpecial Features: Circle or dot laser sighting, range -20 to 420 degrees c; resoulution 1 degree C/1 degree f; repeatability +1 degree c; emissivity 0.95 fixed; spectral response 6-14MM; optical field of view D:S=8.1; response time 500MS; storage ambient -20 to 5 degrees C less than 90% of humidity; 0 to 50 degree C less than 80% fo humidity; ambient temperature +5 degrees C, calibrated by black body emissivity at 0.95; power: 9 volt battery, included; in-process temperature measurement, fire and safety, plastics molding, marine and rv, food safety; not to be used to measure body temperature; for industridal and scientific purposes
Part Name Assigned BY Controlling Agency: Thermometer infrared dot laser sighting
Overall Length: 1.600 inches nominal
Omega Engineering Inc. (29907)

Quote

OSK2K2816 6685-00-556-1896Thermometer, Indicating, CapillaryScale Type: DIAL
Special Features: Thermometer dial 3 1/2; gas, vapor or mercury actuated
Scale Measurement Range: +20.000/+240.000 deg fahrenheit
Omega Engineering Inc. (29907)

Quote

  • We solve sourcing challenges for OILTEMPERATURERSYSTEM/OPTIONS, OM-272-ALM, OMNI-CAL-4A, OMNI-CAL8A, OPA3000000-0, OPT-CY16, ORC-26-340, ORC-26-350, OS101-MA-SS, OSK2K2816 - NSN parts, hard to find, long lead time and obsolete components.