Pressure, Temperature, and Humidity Measuring and Controlling Instruments: MPG90433-2, MPL85322, MR150AFMH
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
MPG90433-2 MPG904332 | 6685-00-941-7058 | Control, Temperature, Indicating | Special Features: Dust proof and moisture proof Case Material: Brass Mounting Method: Bulkhead | Engineered Air Systems Inc. (90598) | |
MPL | 6685-00-731-1782 | Thermostat, Flow Control | Usage Design: Gas control Mounting Method: Threaded Spring Operated Pressure Relief: Provided | Johnson Controls Inc. (06541) | |
MPL85321 | 6685-01-290-0950 | Controller, Temperature | END Item Identification: LGM-30 launch facility, environmental control system General Characteristics Item Description: Reverse acting; remote range M10 to P120 deg f; element 35 ft length, averaging; mounting surface or panel | Engineered Air Systems Inc. (90598) | |
MPL85322 | 6685-00-084-1395 | Control, Temperature, Recording | Power Source: External Inclosure Type: Encased Maximum Overall Width: 3.125 inches | Engineered Air Systems Inc. (90598) | |
MPL89363-1 MPL893631 | 6685-00-915-9394 | Thermometer, Indicating, Capillary | Scale Type: Concentric dial Special Features: Green area M20 deg to P43 deg on scale red area P43 to P110 deg on scale Scale Smallest Increment: 1.0 deg fahrenheit | Engineered Air Systems Inc. (90598) | |
MPL90441-14 MPL9044114 | 6685-01-123-3033 | Control, Temperature, Indicating | END Item Identification: LGM30 missile system Special Features: Pnuematic temperature control which operates with A 25 psig maximum regulated air supply;contains two gages;one to monitor inlet the other to monitor control pressures;has A 0-4 psi sensitivity per deg. F.;temperature adjustment is concealed;surface mounted;ambient temperature operating ranges fromminus 10 deg. F. to +300 deg. F.;temperature included with dial markings of 2 deg. F. per controling range;furnished with control are 4 1/8 in pipe PLUGS;2 ELBOWS;2 oriface FITTINGS;2 no 10X1 3/4 in mounting screws;capillary tube and bulb is stainless steel and fully compensated;bulb is 4 in long;capillary tube is 50 ft long Mounting Method: Bulkhead | Engineered Air Systems Inc. (90598) | |
MPL90441-20 MPL9044120 | 6685-01-122-1710 | Control, Temperature, Indicating | END Item Identification: LGM30 missile system Special Features: Pnuematic temperature control which operates with A 25 psig maximum regulated air supply;contains two gages;one to monitor inlet the other to monitor control pressures;has A 0-4 psi sensitivity per deg. F.;temperature adjustment is concealed;surface mounted;ambient temperature operating ranges fromminus 10 deg. F. to +300 deg. F.;temperature included with dial markings of 2 deg. F. per controling range;furnished with control are 4 1/8 in pipe PLUGS;2 ELBOWS;2 oriface FITTINGS;2 no 10X1 3/4 in mounting screws;capillary tube and bulb is stainless steel and fully compensated;bulb is 4 in long;capillary tube is 8 ft long Mounting Method: Bulkhead | Engineered Air Systems Inc. (90598) | |
MPL90441-5 MPL904415 | 6685-01-122-1709 | Control, Temperature, Indicating | END Item Identification: LGM30 missile system Special Features: Pnuematic temperature control which operates with A 25 psig maximum regulated air supply;contains two gages;one to monitor inlet the other to monitor control pressures;has A 0-4 psi sensitivity per deg. F.;temperature adjustment is concealed;surface mounted;ambient temperature operating ranges fromminus 10 deg. F. to +300 deg. F.;temperature included with dial markings of 2 deg. F. per controling range;furnished with control are 4 1/8 in pipe PLUGS;2 ELBOWS;2 oriface FITTINGS;2 no 10X1 3/4 in mounting screws;capillary tube and bulb is stainless steel and fully compensated;bulb is 4 in long;capillary tube is 8FT long Mounting Method: Bulkhead | Engineered Air Systems Inc. (90598) | |
MPL90443-2 MPL904432 | 6685-01-122-1711 | Control, Temperature, Indicating | END Item Identification: LGM30 missile system Special Features: Pnuematic temperature control which operates with A 25 psig maximum regulated air supply;contains two gages;one to monitor inlet the other to monitor control pressures;has A 0-4 psi sensitivity per deg. F.;temperature adjustment is concealed;surface mounted;ambient temperature operating ranges fromminus 10 deg. F. to +300 deg. F.;temperature included with dial markings of 2 deg. F. per controling range;furnished with control are 4 1/8 in pipe PLUGS;2 ELBOWS;2 oriface FITTINGS;2 no 10X1 3/4 in mounting screws;capillary tube and bulb is stainless steel and fully compensated;bulb is 4 in long;capillary tube is 8 ft long Mounting Method: Bulkhead | Engineered Air Systems Inc. (90598) | |
MPL90443-3 MPL904433 | 6685-01-122-1712 | Control, Temperature, Indicating | END Item Identification: LGM30 missile system Special Features: Pnuematic temperature control which operates with A 25 psig maximum regulated air supply;contains two gages;one to monitor inlet the other to monitor control pressures;has A 0-4 psi sensitivity per deg. F.;temperature adjustment is concealed;surface mounted;ambient temperature operating ranges fromminus 10 deg. F. to +300 deg. F.;temperature included with dial markings of 2 deg. F. per controling range;furnished with control are 4 1/8 in pipe PLUGS;2 ELBOWS;2 oriface FITTINGS;2 no 10X1 3/4 in mounting screws;capillary tube and bulb is stainless steel and fully compensated;bulb is 4 in long;capillary tube is 50 ft long Mounting Method: Bulkhead | Engineered Air Systems Inc. (90598) | |
MPL90450-1 MPL904501 | 6685-01-340-6330 | Control, Temperature, Indicating | END Item Identification: GM-30MISSLE Special Features: Adjustable temp. range pos. 56 TOPOS.65 deg. f;adjustable sensitivity from 1 to 4 psi per degree;max. supply air PRESSURE-25 psi;equipped W/visiblethermometer;reverse acting | Engineered Air Systems Inc. (90598) | |
MPL90477-1 MPL904771 | 6685-00-915-9394 | Thermometer, Indicating, Capillary | Scale Type: Concentric dial Special Features: Green area M20 deg to P43 deg on scale red area P43 to P110 deg on scale Scale Smallest Increment: 1.0 deg fahrenheit | Engineered Air Systems Inc. (90598) | |
MPM 500 MPM500 | 6685-01-302-3691 | Hygrothermometer, Digital | Special Features: General features-has hold/alternate selector for measurement; function selector for 6 measurement types plus battery status; digital display 4 1/2 innch lcd controlled by microprocessor with polarity, low battery, decimal points, engineering units and special function indications; display hold to hold current display; min/max switch for displaying min/max readings; symbol change switch; average switch; case is molded impact resistant abs, is water resistant, has integral stand for bench use or wall mounting; 14 engineering units displayed-pressure in psi, inches H2O, bar and pascal, airspeed in M/sec or ft/min; temp and dewpoint in deg C or f; battery 9 volt alkaline size PP3; battery life 12 to 25 hrs continuous use; weight 19.3 oz W/battery;usage conditions 0 to 50 deg c; high accuracy Operating Temp Range: +0.0/+50.0 deg celsius Display Type: Liquid crystal | Solomat-Neotronics (78808) | |
MPM 500E MPM500E | 6685-01-302-3691 | Hygrothermometer, Digital | Special Features: General features-has hold/alternate selector for measurement; function selector for 6 measurement types plus battery status; digital display 4 1/2 innch lcd controlled by microprocessor with polarity, low battery, decimal points, engineering units and special function indications; display hold to hold current display; min/max switch for displaying min/max readings; symbol change switch; average switch; case is molded impact resistant abs, is water resistant, has integral stand for bench use or wall mounting; 14 engineering units displayed-pressure in psi, inches H2O, bar and pascal, airspeed in M/sec or ft/min; temp and dewpoint in deg C or f; battery 9 volt alkaline size PP3; battery life 12 to 25 hrs continuous use; weight 19.3 oz W/battery;usage conditions 0 to 50 deg c; high accuracy Operating Temp Range: +0.0/+50.0 deg celsius Display Type: Liquid crystal | Solomat-Neotronics (78808) | |
MPU-1MATCHEDPAIR MPU1MATCHEDPAIR | 6685-01-018-2735 | Thermocouple | Levinson Harry Co. (53681) | ||
MQE71A | 6685-00-526-8753 | Thermometer, Indicating, Capillary | END Item Identification: Missile minuteman LGM-30 Scale Type: Concentric dial Scale Smallest Increment: 10.0 deg fahrenheit | Thermo King Corporation (61510) | |
MR10B250 | 6685-01-188-5922 | Regulator, Pressure | General Characteristics Item Description: Brass, outlet pressure 0-100 psig; connection, 0.250 in. npt, female, O/A lg 4.250 in. nom; auto self-relieving; panel mount; fluid media, corrosive and non-corr gases and liquids; temp range M 40 deg F to 160 deg f; optional safety valve and cga fitting; brass | Circor Aerospace Inc. (91816) | |
MR10B250GR | 6685-00-423-6701 | Regulator, Pressure | General Characteristics Item Description: Brass, 0 to 100 psig, with safety valve, inlet and outlet gage | Circor Aerospace Inc. (91816) | |
MR-150 MR150 | 6685-00-004-7388 | Pyrometer, Optical | Raytek Inc. (50865) | ||
MR150AFMH | 6685-00-004-7388 | Pyrometer, Optical | Raytek Inc. (50865) |