Pressure, Temperature, and Humidity Measuring and Controlling Instruments: 123-9335, 123DJ3C, 123NID15A21-X

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
123-9335
1239335
6685-00-659-6925Transmitter, Temperature, ElectricOverall Length: 1.844 inches minimum and 1.906 inches maximum
Style Designator: Transmitter, 24V dc
Operating Temp Range: +37.8/+111.7 deg celsius
Asset Systems Inc. (06350)

Quote

123-9338
1239338
6685-00-454-7530Indicator, Temperature, ElectricalCurrent Type: DC
Contact Quantity: 2
Length: 2.100 inches nominal
Asset Systems Inc. (06350)

Quote

123AM2 6685-01-035-6962Transducer, low Cooling EffectEND Item Identification: F-15 acft
General Characteristics Item Description: 5.562 in. O/A lg, 2.50 in. porm 0.03 in. O/A dia, contains 2 reference grade platinum sensing elements, electrical connection MS27476 Y10ESP per MIL-C-38999D
Rosemount Aerospace Inc. (60678)
Rosemount Inc. (04274)

Quote

123AM3 6685-01-068-1480Transducer, low Cooling EffectEND Item Identification: R/N 68A870064-1015 and R/N 68A870064-1017
General Characteristics Item Description: 5.562 in. O/A lg., 2.50 in. O/A dia.; similar to R/N 123AM2
Rosemount Aerospace Inc. (60678)
Rosemount Inc. (04274)

Quote

123D412-2
123D4122
6685-00-293-4444Detector, Probe AssemblyEND Item Identification: F14A acft
General Characteristics Item Description: Eprobe shell and probe shaft, stainless steel, heater contact, silver, operating VOLTAGE115 V, ac, resistance 95.0 to 130.0 ohms, circuit opens at 280.0 deg F on temp rise, closes at 250.0 degf on temp drop
Avionics Specialties Inc. (10639)

Quote

123DJ2 6685-01-263-0417Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 25 deg F at 4 lb/min to 80 deg F at 7.5 to 8.0 lb/min;normal operating range 25 to 80 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 3.0 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.51 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ2C 6685-01-263-0417Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 25 deg F at 4 lb/min to 80 deg F at 7.5 to 8.0 lb/min;normal operating range 25 to 80 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 3.0 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.51 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ3 6685-01-263-0418Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 25 deg F at 7 lb/min to 80 deg F at 7.0 to 8.0 lb/min;normal operating range 25 to 80 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 4.5 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.76 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ3C 6685-01-263-0418Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 25 deg F at 7 lb/min to 80 deg F at 7.0 to 8.0 lb/min;normal operating range 25 to 80 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 4.5 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.76 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ4 6685-01-263-0419Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 15 deg F at 10 lb/min TO90 deg F at 18.0 to 20 lb/min;normal operating range 25 to 80 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 4.5 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.76 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ4C 6685-01-263-0419Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 15 deg F at 10 lb/min TO90 deg F at 18.0 to 20 lb/min;normal operating range 25 to 80 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 4.5 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.76 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ5 6685-01-370-6725Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 45 deg F at 2 lb/min to 120 deg F at 5.0 to 6.5 lb/min;normal operating range 45 to 120 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 3.0 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.51 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DJ5C 6685-01-370-6725Sensor, Air UndercoolEND Item Identification: Pacer special
Special Features: Sensor checks that cooling flow and/or cooling temperature is above following curve, 45 deg F at 2 lb/min to 120 deg F at 5.0 to 6.5 lb/min;normal operating range 45 to 120 deg f;when the cooling flow and/or cooling temp falls below the curve the sensor will detect insufficient cooling and switch from N.O. to N.C switch spdt 2A min RATING;8 pin connector;switching, pins 3 to 4 normally CLOSED;4-5 normally open; operating voltage 28 vdc
General Characteristics Item Description: To be used in 3.0 inch dia. duct;weight 0.75 lbs;sensor incorporates an output delay of 140 pom 15 seconds;environment minus 65 degrees to 190 deg F, 1.0 to 15.5 psia;accuracy 5% full scale;end fitting per MS33514E4;RECEPTACLE to mate with D38999/26WC8S connector keying d;probe length 3.51 inches pom 0.04 inch
Rosemount Aerospace Inc. (60678)

Quote

123DP1 6685-01-491-5501Thermocouple, ImmersionEND Item Identification: E-8A
Special Features: Unit completes circuit that allows illumination of warning lamps on the aircraft
Part Name Assigned BY Controlling Agency: Detector - cooling effect & star detector
Rosemount Aerospace Inc. (60678)

Quote

123DR1 6685-01-490-5290Thermocouple, ImmersionSpecial Features: Supplies an analog signal as A function of the cooling effect
Part Name Assigned BY Controlling Agency: Detector - colling effect: star detector
Operating Temp Range: -71.0/+185.0 deg fahrenheit
Rosemount Aerospace Inc. (60678)

Quote

123DR3 6685-01-511-0052Sensor, Ambient TemperatureEND Item Identification: E8 airplane
Special Features: Zmonitors temperature air cooling avionics equipment, provides analog signal as A function of cooling effect to A pair of connector pins, acc P/M 5% full scale, mtbf 50, 000, mounts on 4IN od circular duct, manufacturers name heat detector
Actuation Type: Thermocouple
Rosemount Aerospace Inc. (60678)

Quote

123F1A15A01-CP
123F1A15A01CP
6685-01-539-6833Gage, Pressure, Dial IndicatingEND Item Identification: F-22 raptor
Scale Type: DIAL
Scale Range: +0.0/+5000.0 pressure
Perma-CAL Industries Inc. (59018)

Quote

123FID06A26 6685-01-300-9496Gage, Pressure, Dial IndicatingScale Type: Single
Scale Range: +0.0/+200.0 pounds pressure per square inch
Scale Name: Pressure
Perma-CAL Industries Inc. (59018)

Quote

123NID07A21-X
123NID07A21X
6685-01-442-8419Gage, Pressure, Dial IndicatingScale Range: +0.0/+300.0 pounds pressure per square inch
Perma-CAL Industries Inc. (59018)

Quote

123NID15A21-X
123NID15A21X
6685-01-442-8422Gage, Pressure, Dial IndicatingScale Range: +0.0/+5000.0 pounds pressure per square inch
Perma-CAL Industries Inc. (59018)

Quote

  • We solve sourcing challenges for 123-9335, 123D412-2, 123DJ2C, 123DJ4C, 123DJ5, 123DJ5C, 123DR1, 123DR3, 123FID06A26, 123NID15A21-X - NSN parts, hard to find, long lead time and obsolete components.