Physical Properties Testing and Inspection: RCF-80200, RD25-25, RF-5408-RI001
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
RCF-80200 RCF80200 | 6635-01-105-6844 | Sieve, Test | Material: Brass Design Type: Woven wire cloth Surface Treatment: Any acceptable | Boart Longyear Company (8V019) | |
RCQ1086 | 6635-00-575-4642 | Magnetic Inspection unit, Station | Special Features: 500 lb pressure in air cylinder; 60 psi in air line Functional Description: A heavy duty unit designed for general purpose inspection of large machine parts, using the wet method of inspection. it provides low-voltage, high-amperage dc. the rated maximum output is 5.500 amperes dc. Current Type: AC | Illinois Tool Works Inc. (37676) | |
RCR | 6635-00-531-6048 | Tester, Material Hardness | Carrying Case: Provided Installation Design: Portable Indicator Type: Circular dial | Newage International Inc. (92297) | |
RD-100 RD100 | 6635-01-051-0594 | Test set Subassembly, Physical Pr | Ling Electronics Inc. (06510) | ||
RD25-2 RD252 | 6635-01-352-1636 | Transducer, Ultrasonic Test | Overall Diameter: 0.250 inches nominal Transmitter Frequency Rating: 5000.0 kilohertz nominal | Ultran Laboratories Inc. (8R947) | |
RD25-25 RD2525 | 6635-01-053-7819 | Transducer, Supersonic Test | End Item Identification: F-16 acft Special Features: 25.000 mhz freq.; 0.250 in. dia.; 0.800 in. l; micro dot connector, fluid couplant; fsc application data:ultrasonic flaw detector | Ultran Laboratories Inc. (8R947) | |
RDC-1 RDC1 | 6635-01-530-7747 | Tester, Material Hardness | Special Features: This test method is based on the penetration of A specific type of indentor when forced into the material under specified conditions Part Name Assigned BY Controlling Agency: Rubber property-durometer hardness Carrying Case: Not provided | Schultes Precision Mfg Inc. (35NU1) | |
RDC 13/2 RDC132 | 6635-01-417-5024 | Probe, Eddy Current | Special Features: Nain probe, 2.25 mhz; dia of PROBE0.625 in. body, transducer surface dia 0.50 in.; probe comes with removable delay and transmit 2.25 mhz ultrasonic pulse that can be transmitted into material under inspection END Item Identification: C-17 acft TIP Termination Type: Probe | Quality Material Inspection Inc. (58272) | |
RDC6/10 RDC610 | 6635-01-407-6267 | Probe, Eddy Current | Special Features: Uain probe, 10.0 mhz cd; 10MHZ ultrasonic pulse transmitted into the under inspection for materials 2 to 10 ply END Item Identification: Nsn 6635-01-399-1772, P/N 9017072, detector, metal flaw TIP Termination Type: Probe | Quality Material Inspection Inc. (58272) | |
RDC6/5 RDC65 | 6635-01-407-6268 | Transducer, Ultrasonic Test | Special Features: Mfg name: probe, 5 mhz X-ducer, was called probe eddy current. used to test material 10 to 20 plies thick. has microdot connector END Item Identification: Nsn 6635-010-399-1772, P/N 9017072, detector, metal flaw Overall Length: 2.000 inches nominal | Quality Material Inspection Inc. (58272) | |
RDG014 | 6635-01-418-8694 | Transducer, Ultrasonic Test | Special Features: 1/2IN DIA.;1.0 mhz;replacement delay line model END Item Identification: Support equipment, B-2 bomber;cbil Case Material: Steel corrosion resisting | Curlin Healthcare Products Inc. (54136) | |
RDG024 | 6635-01-411-0384 | Transducer, Ultrasonic Test | Special Features: Delay line model;replaceable delay;opti-grip surface END Item Identification: Support equip (se), B-2 bomber;cbil | Curlin Healthcare Products Inc. (54136) | |
RDG054 | 6635-01-418-8693 | Transducer, Ultrasonic Test | Special Features: 5.0 mhz, replacement delay line modell END Item Identification: Support equipment, B-2 bomber;cbil Case Material: Steel corrosion resisting | Curlin Healthcare Products Inc. (54136) | |
RDM101-1 RDM1011 | 6635-01-111-5688 | Monitor, Respirable Dust | General Characteristics Item Description: On-the-spot measurements of mass concentrations of the respirable fraction or total mass loading up to 20 micrometers in aerodynamic diameter of dust particles, portable and fully self-contained monitor with automatic and direct digital readout of the mass concentration of airborne dust, lwh 9X3.5X4 inches, 12 V battery | Precision Scientific Petroleum (48619) | |
RDS001 | 6635-01-572-5251 | Desealing Tool, Pneumatic | Special Features: Usable in explosive atmosphere; replacement parts: RDS-TIPS-100 0.5IN tips (100), RDS-TIPS-25 0.5IN tips (25), RDS004 2IN shaft; RDS005 service kit Part Name Assigned BY Controlling Agency: Rapid desealing system Overall Length: 13.000 inches nominal | Aerowing Inc. (3FM31) | |
RE22685 | 6635-01-552-0010 | Detector kit, Water, Automotive-Av | Deere & Co. (75160) | ||
RECHII-3181 RECHII3181 | 6635-01-114-0364 | Hole Inspector, Eddy Current | END Item Identification: F100 turbofan engine, pratt and whitney General Characteristics Item Description: Fc/O rotary eddy current hole inspetion instrument: 16.000 in. L, 11.000 in. W, 6.000 in. h; recorder: 11.400 in. lg, 8.500 in. W, 3.900 in. h; rotary current scanner 6.000 in. lg, 4.000 in. W, 3.000 in. H | Olympus NDT NE Inc. (29192) | |
RECHII-I RECHIII | 6635-01-134-6289 | Tester, Eddy Current Hole | General Characteristics Item Description: Consists of ra scanner 1; A-scan recorder module 1; rechii recorder 1 | Olympus NDT NE Inc. (29192) | |
RES0TR0N1000 | 6635-00-432-2314 | X-Ray Apparatus, Radiographic, Ind | Special Features: Xcontrol, DIM.32.000 in.lg, 18.000 in.W, 80.000 in.H, tube unit, DIM.86.000 in.lg, 36.000 dia, ratings, 500000 to 1000000 peak V kvp at 0.1 to 3.0 ma, resonant freq 180 hz, operating power, 198 to 242V or 396 to 484V, three phase, 37.5 kva, 60 hz | General Electric Co. (24456) | |
RF-5408-RI001 RF5408RI001 | 6635-01-570-4674 | X-Ray Apparatus, Radiographic, Ind | Harris Corporation (14304) |