Physical Properties Testing and Inspection: PD92LDE66350155, PD-LDEN-236E, PDSANE235

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
PD92LDE66350155 6635-01-363-6674Test set, UltrasonicSpecial Features: 3NAIN inspection system, ultrasonic, portable;ac & dc currents; 115.0-230.0, 50-60 hz; single phase; O.5 amps; 18.000 in. L, 12.000 in. W, 8.000 in. h; C/O ultrasonic instrument, 2 batteries, bbattery charger/eliminator W/padded corrosion resistant carrying case; sinusoidal or square wave; pulse width range 30-1000 ns; 300 V pulse; 0.5-20 mhz freq range; displays fullwave, filtered, halfwave porm rf; timebase 1-1200 msec min; digital analog signal & storagefor disk recorders; bnc connector, ttl compatible
Carrying Case: Provided
Functional Description: Performs ultrasonic inspections for crack detection, corrosion and thickness testing
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD94LDEN66350159 6635-01-396-2798Magnetic Inspection unit, StationSpecial Features: Max contact head opening 52 in. porm 2 in.; wet horizontal machine; output: dc 6000 amps with not more than 6PCT ripple, ac 5000 amps; digital ammeter displays ac rms amps or dc amps atcoil or contacts; current continuouslyvariable; headstock pressure foot switch activated; input air pressure 80-90PSI
Functional Description: Capable of magnetizing workpiecesin logitudinal and circular directionsof ferromagnetic parts
Current Type: Ac and dc
SAN Antonio Air Logistics Center (98750)

Quote

PD95LDNTILDD-9
PD95LDNTILDD9
6635-00-110-9463Fluorescent Penetrant InspectionSpecial Features: C/O penetrant, penetrant drain, emulsification, emulsification drain, rinse, developer drain, dryer, cooler and inspection stations, the penetrant, emulsification, developer stations, C/O frame, tank and cover, id of tank, 43.000IN. lg., 29.000 in.W, 26.000 in. deep, rinse station tank id 43.000 in. LG.29.000 in. W, 24.000 in. deep, frame size, 48.000 in. lg, 34.000 in. W, table 36.000 in. H, dryer station dim. 67.000 in. lg, 28.000 in. W, 24.000 in. H, heater capacity 8000 W, two fans, cooler station C/O frame and full roller grille, 48.000 in. lg, 34.000 in. W, table lg 36.000, inspection station C/O frame, roller grille table top, dust pan, exaust fan, two black lights, junction box and canopy, O/a dim. 72.000 in. lg, 58.000 in. W, 78.000IN.H, all frames are of structural steel angles, tanks are of 16 guage carbon steel, dryer stations hot-air recirculating type, thermostat control from 50 deg. F to 500 deg. F
Nondefinitive Spec/STD Data: MA-2 type
SAN Antonio Air Logistics Center (98750)

Quote

PD96LDE66350172 6635-01-425-8848Processing Machine, RadiographicSpecial Features: 220 vac, 3-WIRE single phase, 50/60 hz, 40 amp; 700 lbs; processor shall be able to handle at least 55 sheets of 14" X 17" industrial radiographic film
Part Name Assigned BY Controlling Agency: Processing machine, radiographic film, automatic, stationary (specification name), alternate names film processor, & processing unit, X-ray, ndi inspection
Replenisher Solution Tank Quantity: 1
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PD96LDE66350173 6635-01-425-8846Processing Machine, RadiographicSpecial Features: 110 or 220 vac, 3 wire single phase, 50/60 hz, 20 amp; this ia A deployable unit; max weight 225 lbs; processor shall be capable of handling at least 25 sheets of 14 in X 17 in industial radiographic film
Part Name Assigned BY Controlling Agency: Processing machine, radiographic film, automatic, deployable (specification name); alternate names: film processor, & processing unit, X-ray ndi inspection
Replenisher Solution Tank Quantity: 1
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PDA0SC 6635-00-395-8741Detector, Metal Flaw, ElectronicSpecial Features: 12V battery operated; oscillator generates A 15W, 750HZ stable ac audiofrequency signal
Accessory Components AND Quantity: Headphone set 1; shoe cleats W/straps 1PR; 9.000 in. belt-worn terminal board
Tinker and Rasor (26395)

Quote

PD-AFRL-03-59131
PDAFRL0359131
6635-00-463-1574Detector, Metal Flaw, ElectronicCarrying Case: Provided
Usage Design: External
Indicator Type: Electron-ray tube
Air Force United States Department (98748)

Quote

PD-AFRL-03-74-322
PDAFRL0374322
6635-00-292-7637Interlock Assembly, X-RayEND Item Identification: 6635-00-018-5835
Part Name Assigned BY Controlling Agency: X-ray interlock assembly
Overall Length: 6.000 inches nominal
Warner Robins Air Logistics Center (98752)

Quote

PD-AFRL-03-74-322
PDAFRL0374322
6635-01-508-1519Interlock Assembly, X-Ray SafetyEND Item Identification: 6635-01-394-5926
Overall Length: 8.000 inches nominal
Functional Description: Used with lorad 160KV and sperry 300KV X-ray units. when installed the interlock ensures the X-ray warning lights are connected before permitting the X-ray tube to be energized
Warner Robins Air Logistics Center (98752)

Quote

PDL1035 6635-01-330-0335Transducer, Supersonic TestMastercraft Enterprises Inc. (55254)

Quote

PDL-1035J
PDL1035J
6635-01-525-7801Transducer, Ultrasonic TestSpecial Features: Name assigned by manufacturer ultrasonic transducer special wave
END Item Identification: Fixed wing aircraft C130J
Qualtech Inc. (0ETL4)

Quote

PDL1036 6635-01-299-0744Transducer, Supersonic TestMastercraft Enterprises Inc. (55254)

Quote

PDL-1036J
PDL1036J
6635-01-525-7800Transducer, Ultrasonic TestSpecial Features: Name assigned by manufacturer ultrasonic transducer special wave
END Item Identification: Fixed wing aircraft C130J
Qualtech Inc. (0ETL4)

Quote

PD-LDEN-236E
PDLDEN236E
6635-01-372-3089Gage, Thickness, UltrasonicGeneral Characteristics Item Description: C/O case which accomodates gage, battery charger power cable, spare transducer and cables, steel and aluminumgage blocks, spare fuse, couplant; digital display of thickness measurement;scope; tilt-bail handle; battery; 100-250 V ac, single phase, 50-60 hz; battery; 6 ft. detachable battery cable; measurement range of steel/aluminum: low scale 0.0070 to 0.1950 in.; high scale 0.050 to 1.990 in. (thickness); steel and aluminum gage blocks of 0.007, 0.010, 0.020, 0.100, 0.200, 0.500, 1.000, L.500, and 2.000 in. thickness with tolerance of 0.0005 in. provided, steel blocks are nickel plated, al blocks are anodized
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PDO4WRAFRL02 6635-01-528-4985Light, Ultraviolet, Metals ExaminiWarner Robins Air Logistics Center (98752)

Quote

PDO4WRAFRL29 6635-00-242-1500Cooler, X-Ray Film Processing UniFSC Application Data: Cgeneral purpose use
Warner Robins Air Logistics Center (98752)

Quote

PDS1-400-05-10
PDS14000510
6635-01-476-0291Test meter kitSpecial Features: Led display; meter accuracy of plus or minus 1 percent; hold and display feature; portability; rigid metal carrying case; display level of up to 12000 amperes; model DTM25
Army United States Department of, The (19204)
Hand Punch Supply (1NS09)
Parker-Hannifin Corporation (97111)
Raufeisen Enterprises (1NSQ9)

Quote

PDS3-FRS
PDS3FRS
6635-01-476-0291Test meter kitSpecial Features: Led display; meter accuracy of plus or minus 1 percent; hold and display feature; portability; rigid metal carrying case; display level of up to 12000 amperes; model DTM25
Parker-Hannifin Corporation (97111)

Quote

PD-SA-ALC/LDE100
PDSAALCLDE100
6635-01-059-2606Processing Machine, RadiographicCurrent Type: AC
Voltage IN Volts: 230.0
Frequency Rating: 60.0 hertz nominal
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PDSANE234 6635-00-242-1500Cooler, X-Ray Film Processing UniFSC Application Data: Cgeneral purpose use
SAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

PDSANE235 6635-00-242-1498Leak Detector, UltraSAN Antonio Air Logistics Center (98750)
Warner Robins Air Logistics Center (98752)

Quote

  • We solve sourcing challenges for PD92LDE66350155, PD94LDEN66350159, PD95LDNTILDD-9, PDA0SC, PD-AFRL-03-59131, PDL-1036J, PD-LDEN-236E, PDO4WRAFRL02, PDS3-FRS, PDSANE235 - NSN parts, hard to find, long lead time and obsolete components.