Physical Properties Testing and Inspection: NDT-123, NDT-127, NDT 30
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
NDT-123 NDT123 | 6635-01-060-6221 | Gage, Material Thickness | General Characteristics Item Description: Powered by 2 nickel cadmium batteries, dim. 6.000 in. lg, 3.000 in. W, 2.000 in. H, 2 ranges, 0.050 in. thickness to 10.000 in., 10.000 in. thickness to 20.000 in., accurate porm 0.001 in. when measuring under 2.000 in., accurate porm 0.010 in. when measuring over 2.000 in., 4 digit led display | Olympus NDT NE Inc. (29192) | |
NDT-127 NDT127 | 6635-01-047-3983 | Tester, Material Thickness | General Characteristics Item Description: C/O crt display; large lcd digital readout; 3.5-DIGIT readout of thickness between 0.007 in. to 1.999 in. of steel or aluminum; line or DC(6 hr. battery) operation; internal battery charger; multiple mode or W/contact pulseecho measurement; liquid crystal display; resolution 0.1 mil on 200 mil range; wide band test frequency | Olympus NDT NE Inc. (29192) | |
NDT131 | 6635-01-086-5863 | Test set, Ultrasonic | Carrying Case: Provided Usage Design: External Indicator Type: Electron-ray tube | Olympus NDT NE Inc. (29192) | |
NDT-131D NDT131D | 6635-01-114-0363 | Ultrascope, Digital | END Item Identification: F100 turbofan engine, pratt and whitney General Characteristics Item Description: 16.000 in. lg, 11.500 in. W, 8.500 in. H | Olympus NDT NE Inc. (29192) | |
NDT-15 NDT15 | 6635-01-061-3625 | Magnetic Inspection unit, Portabl | Olympus NDT NE Inc. (29192) | ||
NDT-16 NDT16 | 6635-01-113-8368 | Eddy Current Test System | END Item Identification: F100 turbofan engine, pratt and whitney General Characteristics Item Description: C/O test set: O/A dim. 20.000 in.lg, 11.600 in. W, 8.500 in. h; recorder: O/A dim. 11.000 in. lg, 8.000 in. W, 4.000 in. H | Olympus NDT NE Inc. (29192) | |
NDT-17 NDT17 | 6635-01-535-1513 | Detector, Metal Flaw, Electronic | Special Features: Special gse allow no prov reqd. T-45C aircraft se/ no prov reqd. END Item Identification: Special aircraft and engine tool and support equiptment Part Name Assigned BY Controlling Agency: Tester elec conduct | Staveley Instruments (0M421) | |
NDT185 | 6635-01-580-8840 | Reference Standard | Olympus NDT NE Inc. (29192) | ||
NDT18S | 6635-01-290-3227 | Eddyscope | Olympus NDT NE Inc. (29192) | ||
NDT-19 NDT19 | 6635-01-283-3395 | Detector, Metal Flaw, Electronic | Special Features: Battery operated; dual memory andfreq; sweep; 8-HR battery life; pos orneg alarm; store 16 test programs; diagonal magnetic deflection; 15.000 in. dia, 5.500 in. H, 12.000 in. w; E/I B-1B bomber Carrying Case: Provided Installation Design: Portable | Olympus NDT NE Inc. (29192) | |
NDT19E | 6635-01-364-5526 | Detector, Metal Flaw, Electronic | Special Features: Freq range F1: 100HZ-3MHZ. F2: 1/2, 1/4, 1/8 or 1/16 of F1; 5 in. digital storage; RS-170 compatible; sidebashows current instrument settings; lcdreadout, 2 lines of 16 char ea; SWEEP:0.005-4.0 sec/div, variable or externally triggered; alarms avail in 5 modeson impedance plane display; differential, absolute, reflection probes; stores up to 100 setups, 20 data storage locations; tape out avail; video OUTPUT;RS-232 compatible; 12 vdc, gelled leadacid battery (8-HR); incl battery charger (120-240 vac, 50/60 hz); 5.500 in.h; 12.000 in. w; 15 in. dp; chassis modular aluminum W/polyurethane bumpers Carrying Case: Not provided Installation Design: Bench | Olympus NDT NE Inc. (29192) | |
NDT19EII-DUAL FREQUENCY NDT19EIIDUALFREQUENCY | 6635-01-439-3081 | Detector, Metal Flaw, Electronic | Special Features: Adjustable to 100 volts per ohm SENSITIVITY;5 inch digital storage resolution | Olympus NDT NE Inc. (29192) | |
NDT19EII-SINGLE NDT19EIISINGLE | 6635-01-439-7607 | Detector, Metal Flaw, Electronic | Olympus NDT NE Inc. (29192) | ||
NDT19E-SINGLE FREQUENCY NDT19ESINGLEFREQUENCY | 6635-01-439-3082 | Detector, Metal Flaw, Electronic | Olympus NDT NE Inc. (29192) | ||
NDT19/RA NDT19RA | 6635-01-453-5038 | Probe, Eddy Current | United Technologies Corporation (77445) | ||
NDT-25 NDT25 | 6635-01-120-1630 | Inspection unit, Eddy Current | General Characteristics Item Description: Wportable microprocessor with crt and lcd digital displays with filters, alarm and X-Y sweep options; frequency RANGE-60 hz to 6 mhz; self contained battery pack with charger; 120 vac 50 to 60 hz, or 24 vdc; push button control panel | Olympus NDT NE Inc. (29192) | |
NDT 25L NDT25L | 6635-01-144-8370 | Tester, Eddy Current | General Characteristics Item Description: C/O ndt 25L eddy current tester W/rechii attachment for ndi procedure development in weapons system testing | Olympus NDT NE Inc. (29192) | |
NDT-25N NDT25N | 6635-01-198-8302 | Detector, Flaw, Electronic | END Item Identification: Avionics support equipment | Olympus NDT NE Inc. (29192) | |
NDT3 | 6635-00-140-5139 | Detector, Metal Flaw, Electronic | Installation Design: Bench or portable Reference Data AND Literature: To 33A1-12-979-1 Unpackaged Unit Weight: 4.000 pounds | Olympus NDT NE Inc. (29192) | |
NDT 30 NDT30 | 6635-01-296-8082 | Film, Radiographic | DU Pont E I DE Nemours and Co. Inc. (82348) | ||
NDT 30 NDT30 | 6635-01-296-8083 | Film, Radiographic | Width: 14.000 inches nominal Length: 17.000 inches nominal Contrast Rating: HIGH | DU Pont E I DE Nemours and Co. Inc. (82348) | |
NDT 30 NDT30 | 6635-01-398-1953 | Film, Radiographic | Special Features: Low speed, double emulsion. ultra-fine grain. astm class I film. ideal for composites or where ultimate image quality is needed. Width: 5.000 inches nominal Length: 7.000 inches nominal | DU Pont E I DE Nemours and Co. Inc. (82348) | |
NDT 30 NDT30 | 6635-01-398-1957 | Film, Radiographic | Special Features: Black and white; low speed, double emulsion; ultra-fine grain; astm class 1 film; ideal for composites or where ultimate image quality is needed. Width: 4.500 inches nominal Length: 10.000 inches nominal | DU Pont E I DE Nemours and Co. Inc. (82348) |