AA58050 TYPE I SIZE 1
AA58050TYPEISIZE1
6635-00-249-5340Fluorescent Penetrant InspectionSpecial Features: C/O penetrant, emulsification, drain, rinse, hot air recirculating dryer, developer, & inspection stations;int. tank size 33.000 in. lg, 16.000 in. W, 14.000 in. h;structural stl frame angles, 16 gage carbon stl TANKS;50 to 500 deg. F thermostat CONTROL;220 or 440 V line, built-in xfrmr 110 or 120 V
Nondefinitive Spec/STD Data: MA-1 type
Federal Specifications (81348)

Quote

A-A-58057
AA58057
6635-00-053-8211Processing Machine, RadiographicSpecial Features: 120/240 vac single pahse 60 hz. 45 amps; lodak industrex film aa, T & M films
Tank Capacity: 10.00 gallons
Tank Material: Steel, stainless
Federal Specifications (81348)

Quote

A-A-58057
AA58057
6635-01-065-1661Processing Machine, RadiographicSpecial Features: Uses 10 gal.developer, 6.5 gal.fixer, 6.0 gal.wash, 1.5 gpm fresh water
Overall Length: 51.000 inches nominal
Functional Description: Self-contained unit used for automatic processing of X-ray film; capable of developing, fixing, washing & drying exposed film; use at intermediate & depot levels of maintenance & at medical facilities
Federal Specifications (81348)

Quote

A-A-58057
AA58057
6635-01-179-5783Processing Machine, RadiographicDrive Type: Chain or gear
Tank Capacity: 30.00 gallons
Film Size Accommodated: 35.0 mm to 17.000 by 14.000 in.
Federal Specifications (81348)

Quote

A-A-58057
AA58057
6635-01-368-8341Processing unit, X-Ray FilmSpecial Features: Continuous roller transport system; 3 cycle speeds: SHORT-8 1/2 min; LONG-12 1/2 min; variable speed; tanks: developer 3.8 gal, fixer 2.4 gal, washwater 2.7 gal incl in 1 tank; automatic temp control via heat exchanger and thermistor; continuous circulation; digital display panel W/lamp; wash water: 41 deg F, 2 gal/min; 200-240 vac, single phase, 50-60 hz; cold water processing; up to 55 sheets per hour; waisthigh delivery
Overall Width: 3.666 feet nominal
Overall Height: 3.583 feet nominal
Federal Specifications (81348)

Quote

A-A-58057
AA58057
6635-01-425-8848Processing Machine, RadiographicSpecial Features: 220 vac, 3-WIRE single phase, 50/60 hz, 40 amp; 700 lbs; processor shall be able to handle at least 55 sheets of 14" X 17" industrial radiographic film
Part Name Assigned BY Controlling Agency: Processing machine, radiographic film, automatic, stationary (specification name), alternate names film processor, & processing unit, X-ray, ndi inspection
Replenisher Solution Tank Quantity: 1
Federal Specifications (81348)

Quote

A-A-58057A
AA58057A
6635-01-425-8848Processing Machine, RadiographicSpecial Features: 220 vac, 3-WIRE single phase, 50/60 hz, 40 amp; 700 lbs; processor shall be able to handle at least 55 sheets of 14" X 17" industrial radiographic film
Part Name Assigned BY Controlling Agency: Processing machine, radiographic film, automatic, stationary (specification name), alternate names film processor, & processing unit, X-ray, ndi inspection
Replenisher Solution Tank Quantity: 1
Federal Specifications (81348)

Quote

A-A-58058
AA58058
6635-01-425-8846Processing Machine, RadiographicSpecial Features: 110 or 220 vac, 3 wire single phase, 50/60 hz, 20 amp; this ia A deployable unit; max weight 225 lbs; processor shall be capable of handling at least 25 sheets of 14 in X 17 in industial radiographic film
Part Name Assigned BY Controlling Agency: Processing machine, radiographic film, automatic, deployable (specification name); alternate names: film processor, & processing unit, X-ray ndi inspection
Replenisher Solution Tank Quantity: 1
Federal Specifications (81348)

Quote

A-A-58058
AA58058
6635-01-449-6933Processing Machine, RadiographicSpecial Features: This is A deployable unit; MD-35APROCESSOR; uses 20 amps max.; weight 235 lbs. with solution or 200 lbs. without any solution
Overall Length: 42.400 inches nominal
Overall Width: 26.5000 inches nominal
Federal Specifications (81348)

Quote

A-A-58072
AA58072
6635-01-417-1830X-Ray Apparatus, Radiographic, IndCurrent Type: AC
Current Rating in Amps: 10.0 or 20.0
Design Type: Portable
Federal Specifications (81348)

Quote

AA58072-2
AA580722
6635-01-394-5926X-Ray Apparatus, Radiographic, IndSpecial Features: N160 kvcp; X-ray tube head-directional, constant potential, end-grounded, gas insulated; control unit-digital microcomputer based; tube window 0.093 in. thick; beam angle from side W/approx 40 deg cone of radiation
Current Type: AC
Voltage IN Volts: 100.0 and 250.0
Federal Specifications (81348)

Quote

AA580722-2
AA5807222
6635-01-417-1830X-Ray Apparatus, Radiographic, IndCurrent Type: AC
Current Rating in Amps: 10.0 or 20.0
Design Type: Portable
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-00-018-5829Test set, UltrasonicCarrying Case: Provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Installation Design: Portable
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-00-296-3332Test set, UltrasonicSpecial Features: 21.000 in. L, 14.000 in.W, 8.000 in. h; 90 to 130 vac, 50 to 60 hz, 100 watts; pulser receiver plug in included
Carrying Case: Provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-00-461-1846Test set, UltrasonicSpecial Features: Model 50E583 plug-N module
Carrying Case: Provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-00-479-5120Test set, UltrasonicCarrying Case: Provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Installation Design: Portable
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-029-7865Test set, UltrasonicSpecial Features: 2.25 mhz, 5.0 mhz, 10.0 mhz freq rng; rf & video display consists of display unit, timer & tube type pulser-receiver
Carrying Case: Provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-046-7349Test set, UltrasonicCarrying Case: Not provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Installation Design: Portable
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-065-1233Test set, UltrasonicSpecial Features: Y37 lbs.; 20.000 in. L, 14.25 in. W, 7.825 in. h; oper temp 20 deg f; 115-220 vac, 50-60 hz; 28 vdc battery PACK;10 mhz; 1 channel; pulse reptition freq. low rng 100-500 hz, med rng 500-1000HZ, high rng 10.003 mhz; portable; selfcontained
Carrying Case: Not provided
Functional Description: Used as thickness gage; detects, locates and evaluates defects such as cracks, defects, deteroriation, corrosion foreign inclusion in metallic & non-metallic materials
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-086-5863Test set, UltrasonicCarrying Case: Provided
Usage Design: External
Indicator Type: Electron-ray tube
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-102-8043Test set, UltrasonicSpecial Features: Manufactures name inspection system, ultrasonic, portable; ac & dc currents; 115.0/230.0 vac, 50/60 hz; single phase; 0.5 amps; 18.000 in. L, 12.000 in. W, 8.000 in. h; C/O ultrasonic instrument, 2 batteries, battery charger/eliminator W/padded corrosion resistant carrying case; sinusoidal or square wave; pulse width range 30-1000 ns; 300V pulse; 0.5-20 mhz freq rng; displays fullwave, filtered, halfwave porm rf; timebase 1-1200 msec min; digital anolog signal & storage for disk recorders; bnc connector, ttl compatible
Carrying Case: Not provided
Functional Description: Performs ultrasonic inspections for cracks detection, corrosion and thickness testing
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-363-6674Test set, UltrasonicSpecial Features: 3NAIN inspection system, ultrasonic, portable;ac & dc currents; 115.0-230.0, 50-60 hz; single phase; O.5 amps; 18.000 in. L, 12.000 in. W, 8.000 in. h; C/O ultrasonic instrument, 2 batteries, bbattery charger/eliminator W/padded corrosion resistant carrying case; sinusoidal or square wave; pulse width range 30-1000 ns; 300 V pulse; 0.5-20 mhz freq range; displays fullwave, filtered, halfwave porm rf; timebase 1-1200 msec min; digital analog signal & storagefor disk recorders; bnc connector, ttl compatible
Carrying Case: Provided
Functional Description: Performs ultrasonic inspections for crack detection, corrosion and thickness testing
Federal Specifications (81348)

Quote

A-A-58073
AA58073
6635-01-417-5467Test set, UltrasonicSpecial Features: Dim. 7.560 in.H, 14.410 in.W, 13.500 in. d; external battery charger, input voltage selectable 110V or 120 V ac;pulse rep. freq 50 to 4000 hz
END Item Identification: Ndi inspection
Carrying Case: Provided
Federal Specifications (81348)

Quote

A-A-58074
AA58074
6635-00-038-4312Test set, UltrasonicCarrying Case: Provided
Functional Description: Used for ultrasonic bond testing equipment of mrtallic & nonmetallic composite material
Installation Design: Portable
Federal Specifications (81348)

Quote

A-A-58074
AA58074
6635-00-432-1540Test set, UltrasonicSpecial Features: 10.000 in. L, 9.000 in. W, 6.500 in. h; oper freq 25KHZ; pulse repetitive rate 20 hz; oper pwr 115VAC, 60 hz, single phase
Carrying Case: Provided
Functional Description: Used for ultrasonic bond testing equipment of mrtallic & nonmetallic composite material
Federal Specifications (81348)

Quote

A-A-58074
AA58074
6635-01-161-4551Test set, UltrasonicCarrying Case: Provided
Accessory Components and Quantity: Battery 6HR 2 sets, battery cable 1 ea, battery charger/eliminator 1 ea, charger interconnect cable 1 ea, pwr cord 1 ea, op manual 1 ea, roll of 1 in W polytetrafluoroethylene tape 1 ea, 30 khz probe 1 ea, 60 khz probe 1 ea, 110 khz probe 1 ea, 165 khz probe 1 ea, 250 khz probe 1 ea, 330 khz probe 1 ea, pitch probe impulse 1 ea, pitch catch probe swept 1 ea, mechanical impedance probe 1 ea, 11 pin to 11 pin probe cable 1E, 11 pin to 4 pin probe cable 1 ea, protective carrying case 1 ea
Usage Design: External
Federal Specifications (81348)

Quote

A-A-58074
AA58074
6635-01-290-2927Test set, UltrasonicSpecial Features: Pwr reqs range 90.0-220.0 vac; 200.00 - 240.0 vac, 50/60 hz
Carrying Case: Provided
Functional Description: Used for ultrasonic bond testing equipment of metallic & nonmetallic composite material
Federal Specifications (81348)

Quote

A-A-58074
AA58074
6635-01-362-3327Test set, UltrasonicSpecial Features: Freq rng 500 hz to 1 mhz; gain rng 0 to 50 db; oper voltage 85-265 vac, 50-400 hz or 110-365 vdc; oper temp -10 to 131 deg f; storage temp -60 to 160 deg F
Carrying Case: Provided
Functional Description: Used for ultrasonic bond testing equipment of metallic & nonmetallic composite material
Federal Specifications (81348)

Quote

A-A-58074
AA58074
6635-01-381-1174Test set, UltrasonicSpecial Features: C/O sonidicator, oper guide, pwr cord, certification, 10VDC battery pack W/9 four-amp-hour size D cells (3 strings)& contact probe; freq 7, 14, 25, 40, 54, 84 & 130 khz; lcd display of freq, phase, signal amplitude; screen size 2.25 in. by 4.25 in.; sample rate, sinewavecycle, drive voltage, analog grain, vertical/horizontal scales, pre-amp; total freq 5-200 khz; audio, visual ttl outputalarms; 16-BIT microprocessor; batterycharger; bnc connectors; RS-232; 115-230 vac, 50-60 hz; 6.5 in H, 10.5 in. W, 14.5 in. dp; 20 lbs
Carrying Case: Provided
Functional Description: Used for ultrasonic bond testing equipment of mrtallic & nonmetallic composite material
Federal Specifications (81348)

Quote

A-A-58077
AA58077
6635-01-394-5926X-Ray Apparatus, Radiographic, IndSpecial Features: N160 kvcp; X-ray tube head-directional, constant potential, end-grounded, gas insulated; control unit-digital microcomputer based; tube window 0.093 in. thick; beam angle from side W/approx 40 deg cone of radiation
Current Type: AC
Voltage IN Volts: 100.0 and 250.0
Federal Specifications (81348)

Quote

A-A-58077
AA58077
6635-01-430-2575X-Ray Apparatus, Radiographic, IndSpecial Features: Mfg name xray apparatus, panaramic; panaramic tubehead, 0.6 nickel beryllium window; control unit 0 to 60KV with lcd readout, pusbutton on xray switch, coolant flow 0.5 gal per min
Current Type: AC
Voltage IN Volts: 110.0
Federal Specifications (81348)

Quote

AA58077-1
AA580771
6635-01-430-2575X-Ray Apparatus, Radiographic, IndSpecial Features: Mfg name xray apparatus, panaramic; panaramic tubehead, 0.6 nickel beryllium window; control unit 0 to 60KV with lcd readout, pusbutton on xray switch, coolant flow 0.5 gal per min
Current Type: AC
Voltage IN Volts: 110.0
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-00-140-5139Detector, Metal Flaw, ElectronicInstallation Design: Bench or portable
Reference Data AND Literature: To 33A1-12-979-1
Unpackaged Unit Weight: 4.000 pounds
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-00-167-9826Detector, Metal Flaw, ElectronicSpecial Features: C/O eddy current instrument 1, battery pack 2 sets, battery charger/eliminator W/cables 1, battery belt 1, conductivity probe & cables 1, reference standards 1 set, probe cable adapters 1, soft shell carrying case 1, hard shell shipping/carrying case 1, harness 1, oper manual 1, familiarization vhs video /accessories opt 1; dim. 11.000 in. L, 6.000 in. W, 6.00 in. h; weight 7 lbs; 115/220 vac, 50/60 hz
Carrying Case: Provided
Functional Description: Light weight eddy current flaw detector for use in the field & depot level for the non-destructive of ferrous & non-ferrous metals
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-00-463-1574Detector, Metal Flaw, ElectronicCarrying Case: Provided
Usage Design: External
Indicator Type: Electron-ray tube
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-00-996-1417Detector, Metal Flaw, ElectronicSpecial Features: Nain inspection unit; 110 vac 60 hz, single phase
Carrying Case: Not provided
Installation Design: Bench
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-01-089-9713Detector, Metal Flaw, ElectronicSpecial Features: C/O eddy current instrument 1, battery pack 2 sets, battery charger/eliminator W/cables 1, battery belt 1, conductivity probe W/cable 1, reference standards 1 set, probe cable adapters 1, soft shell carrying case 1, hard shell shipping/carrying case 1, harness 1, oper manual 1, familiarization vhs video 1, pc interface software/accesories opt 1; dim. 11.000 in. L, 6.000 in. W, 6.000 in h; weight 7LBS; 115/220 vac porm 10%, 50/60 hz
Carrying Case: Provided
Functional Description: Light weight current flaw detector for use in the field & depot level for non-destructive inspection of ferrous & non-ferrous metals
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-01-146-4154Detector, Metal Flaw, ElectronicSpecial Features: Manufactures name tester, eddy current; 8 hr battery; 115/203 vac, 50/60 hz; dim 5.000 in. H, 9.750 in. W, 10.000 in. dp
END Item Identification: Nsn 4920-00-001-4132 shop set, aviation intermediate maintenance
Carrying Case: Not provided
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-01-195-8663Detector, Metal Flaw, ElectronicSpecial Features: Built-in pwr supply/battery charger; audio/visual alarm; earphone recepacle
Carrying Case: Not provided
Installation Design: Portable
Federal Specifications (81348)

Quote

A-A-59131
AA59131
6635-01-455-9520Detector, Metal Flaw, ElectronicCarrying Case: Provided
Usage Design: External
Indicator Type: Electron-ray tube
Federal Specifications (81348)

Quote

A-A-59131A-1
AA59131A1
6635-00-463-1574Detector, Metal Flaw, ElectronicCarrying Case: Provided
Usage Design: External
Indicator Type: Electron-ray tube
Federal Specifications (81348)

Quote

A-A-59309
AA59309
6635-00-111-0456Tester, Torque WrenchNondefinitive Spec/STD Data: 2 size and ia type
Furnished Items: Dial indicator W/ pointer and protective dial cover; housing W/ handle and removable panels

Quote

A-A-59309
AA59309
6635-00-196-2758Tester, Torque WrenchSpecial Features: Single station, dual range or dual station, dual range; 0 to 250 lb-in and 0 to 2000 lb-in
Nondefinitive Spec/STD Data: 9 size and iii type

Quote

A-A-59309
AA59309
6635-00-573-0824Tester, Torque WrenchSpecial Features: 0 to 2000 lb-in range; 0.5 in. male square drive
Nondefinitive Spec/STD Data: I type and 5 size

Quote

A-A-59309
AA59309
6635-00-819-7980Tester, Torque WrenchSpecial Features: 0 to 1000 lb-ft load capacity; 1 in. male sq drive; 1 in. female sq to 1 in. female sq adapter; 1 in. female sq to 3/4 in. female sq adapter; 1 lb-ft max graduation, numbered every 10 lb-ft; 50 lb max weight
Nondefinitive Spec/STD Data: I type and 6 size

Quote

A-A-59309A
AA59309A
6635-00-498-7910Tester, Spring ResiliencyMounting Method: Portable
Operation Method: Manual
Unit Type: Weighing scale

Quote

AA59309-A5
AA59309A5
6635-00-573-0824Tester, Torque WrenchSpecial Features: 0 to 2000 lb-in range; 0.5 in. male square drive
Nondefinitive Spec/STD Data: I type and 5 size

Quote

AA59309-A6
AA59309A6
6635-00-819-7980Tester, Torque WrenchSpecial Features: 0 to 1000 lb-ft load capacity; 1 in. male sq drive; 1 in. female sq to 1 in. female sq adapter; 1 in. female sq to 3/4 in. female sq adapter; 1 lb-ft max graduation, numbered every 10 lb-ft; 50 lb max weight
Nondefinitive Spec/STD Data: I type and 6 size

Quote

AA59309-B7
AA59309B7
6635-00-111-0456Tester, Torque WrenchNondefinitive Spec/STD Data: 2 size and ia type
Furnished Items: Dial indicator W/ pointer and protective dial cover; housing W/ handle and removable panels

Quote

AA59309-C9
AA59309C9
6635-00-196-2758Tester, Torque WrenchSpecial Features: Single station, dual range or dual station, dual range; 0 to 250 lb-in and 0 to 2000 lb-in
Nondefinitive Spec/STD Data: 9 size and iii type
Defense Supply Center Richmond (13873)

Quote

A-A-59380
AA59380
6635-00-530-1128Tensiometer, Dial IndicatingCarrying Case: Provided
Scale Quantity: 1
Scale Range: +10.0 to 200.0 pounds

Quote

A-A-59380
AA59380
6635-00-530-1129Tensiometer, Dial IndicatingCarrying Case: Provided
Mounting Method: Clamp
Scale Quantity: 1

Quote

A-A-59380
AA59380
6635-00-530-1130Tensiometer, Dial IndicatingCarrying Case: Provided
Mounting Method: Clamp
Scale Quantity: 1

Quote

A-A-59380
AA59380
6635-01-375-2019Tensiometer, Dial IndicatingSpecial Features: C9 modified with lanyard
END Item Identification: 14 KC100BL
Carrying Case: Provided

Quote