Optical Instruments, Test Equipment, Components and Accessories: 0041-470, 004827, 005475

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
0041-470
0041470
6650-01-505-2159Eyepiece, MicroscopeEND Item Identification: Centaurus microscope
Special Features: Interocular distance adjustment of 53.0 to 75.0 millimeters
Part Name Assigned BY Controlling Agency: Binocular viewing attachment
Thermo Electron Scientific (52787)

Quote

004333 6650-01-075-3521Light SourceEND Item Identification: Maintenance kit, F100 engine
Kollmorgen Corporation (34228)

Quote

0044437 6650-01-120-5739Lens, Optical InstrumentDiameter: 60.0 millimeters nominal
FSC Application Data: Inspection kit, borescope
Single Lens Style: Plano-convex
Kollmorgen Corporation (34228)

Quote

004448 6650-00-416-2951Reticle and Frame Assembly, R.H.FSC Application Data: Optical assy, lens, R/N 004091
General Characteristics Item Description: C/O frame assy, R/N 004451, 1; leadscrew assy, R/N 004203, 1; pin, straight, R/N 002995, 1; pin, shoulder, R/N 003088, 1; spring compression, R/N 003103, 1; shim, R/N 002541, 1; spirol pin, R/N 003686/5, 3; ball, R/N 003682, 1
Qioptiq LTD (K6111)

Quote

004453 6650-00-416-2942Reticle and Frame Assembly, l.H.FSC Application Data: Optical assy, lens, 004091
General Characteristics Item Description: C/O frame assy, R/N 004455, 1; leadscrew assy, R/N 004204, 1; shim, R/N 002541, 1; spiral pin, R/N 00368614, 2
Qioptiq LTD (K6111)

Quote

004475 6650-00-416-2952Reticle Subassembly, Fiber OpticsGeneral Characteristics Item Description: Kconsists of bracket 2; screw 4; support plate 1; coupling tube 1; lampholder 1; backing plate, L.H. 2; reticle optical instrument, L.H. 1; sleeve 3; clad optical fiber 8000; spring 1; thermofit tubing 3; washer 6
Qioptiq LTD (K6111)

Quote

004475-1
0044751
6650-00-416-2953Reticle Subassembly, Fiber OpticsGeneral Characteristics Item Description: Kconsists of bracket 2; screw 4; support plate 1; coupling tube 1; lampholder 1; backing plate, R.H. 2; reticle optical instrument, R.H. 1; sleeve 3; clad optical fiber 8000; spring 1; thermofit tubing 3; washer 6
Qioptiq LTD (K6111)

Quote

004479 6650-00-231-2744Cell Assembly, Optical InstrumentMaterial: Glass, optical
FSC Application Data: Combiner assy, R/N 004093, 6605-00-169-1409
Accessory Components AND Quantity: Spacer, optical element 3; ring, retaining 1; cell, optical element 1; spiral pin 2
Qioptiq LTD (K6111)

Quote

0045-303
0045303
6650-01-505-4786Optics, MicroscopeEND Item Identification: Continuum infrared microscope
Thermo Electron Scientific (52787)

Quote

0045-402
0045402
6650-01-505-2154Lens, Optical Instrument, MountedEND Item Identification: Continuum and momentum systems
Special Features: 0.58 numerical aperture; working distance 15.0 millimeters
Part Name Assigned BY Controlling Agency: 15X infinity corrected reflachromat objective, variable compensation
Thermo Electron Scientific (52787)

Quote

0045-403
0045403
6650-01-505-2155Lens, Condenser, Microscope LightEND Item Identification: Continuum and momentum systems
Special Features: 0.58 numerical aperture; corrects spherical aberrations caused by infrared windows beneath the sample
Part Name Assigned BY Controlling Agency: 15X reflachromat condenser, variable compensation
Thermo Electron Scientific (52787)

Quote

0045-412
0045412
6650-01-505-2156Eyepiece, MicroscopeEND Item Identification: Continuum/momentum microscope
Special Features: Zinterocular distance adjustment of 53.0 to 75.0 millimeters; accomodates photomicrographic or video equipment; viewing selector allows for observation only, observation and photo, or photo only; rotatable; has 30.0 degree inclination
Part Name Assigned BY Controlling Agency: Trinocular viewing attachment
Thermo Electron Scientific (52787)

Quote

0045-419
0045419
6650-01-505-2157Crystal Holder kitEND Item Identification: Continuum and momentum microscopes
Special Features: Silicon crystal with high refractive indices of 3.4; sample depth of penetration 0.85 micrometers; two modes of operation - view, to view and position sample and ir, used for data collection; contact alert system sensor plate provided
Part Name Assigned BY Controlling Agency: Slide-on attenuated total reflection microscope accessory with silicon crystal
Thermo Electron Scientific (52787)

Quote

00470019 6650-01-080-6854SpectrophotometerWavelength Range: +1900.0/+8500.0 angstroms
Battery: Not included
Design Designation: Czerny-turner
Applied Biosystems LLC (46555)

Quote

004827 6650-01-470-9183Retainer, Optical ElementEND Item Identification: Attack periscope assys P/n's 068008, 069503 and 073003, no nsn's assignedto end items
Part Name Assigned BY Controlling Agency: Retainer, prism
Kollmorgen Corporation (34228)

Quote

004829 6650-01-470-9181Retainer, Optical ElementEND Item Identification: Attack periscope assys P/n's 068008, 069503 and 073003, no nsn's assignedto end items
Part Name Assigned BY Controlling Agency: Retainer, prism
Kollmorgen Corporation (34228)

Quote

004846 6650-01-470-8536Holder, Optical ElementEND Item Identification: Attack periscope assys P/n's 068008, 069503 and 073003, no nsn's assigned to end items
Special Features: Mount, lens
Kollmorgen Corporation (34228)

Quote

004869 6650-01-487-0884Lens, Optical Instrument, MountedEND Item Identification: M374/M374A submarine periscope system
Kollmorgen Corporation (34228)

Quote

005010 6650-01-470-9973Shield, SunshadeEND Item Identification: Attack periscope assys P/n's 068008, 069503, 073003, no nsn's assigned to end items
Kollmorgen Corporation (34228)

Quote

005475 6650-00-406-2644Blade, rod ElectrodeThermo Jarrell Ash Corp. (05234)

Quote

  • We solve sourcing challenges for 0041-470, 0044437, 004448, 004475, 0045-403, 0045-412, 00470019, 004846, 005010, 005475 - NSN parts, hard to find, long lead time and obsolete components.