Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments: LDE3MF, LF6-2, LFA-303KLX

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
LDE3MF 6680-01-028-6147Indicator, Sight, LiquidOverall Length: 3.125 inches nominal
Media FOR Which Designed: Refrigerant, fluorocarbon
Overall Height: 1.062 inches nominal
Tyco Fire Products LP (03670)

Quote

LDE-4S
LDE4S
6680-01-108-7082Indicator, Sight, LiquidOverall Length: 4.870 inches nominal
Overall Height: 1.300 inches nominal
Tube Outside Diameter for Which Designed: 0.500 inches both ends
Hefty Concrete Inc. (87698)
Virginia Chemicals Inc. (58727)

Quote

LDE-5
LDE5
6680-01-141-1558Indicator, Sight, LiquidOverall Length: 4.870 inches nominal
Media FOR Which Designed: Refrigerant, fluorocarbon
Overall Height: 1.300 inches nominal
Virginia Chemicals Inc. (58727)

Quote

LDE-5S
LDE5S
6680-01-141-1558Indicator, Sight, LiquidOverall Length: 4.870 inches nominal
Media FOR Which Designed: Refrigerant, fluorocarbon
Overall Height: 1.300 inches nominal
Virginia Chemicals Inc. (58727)

Quote

LDG605-5A1
LDG6055A1
6680-01-109-5932Indicator, Sight, LiquidLDI Industries Inc. (24346)

Quote

LDR02 6680-01-444-6811Indicator, Sight, LiquidMedia FOR Which Designed: OIL
Furnished Data: Liquid level and liquid temperature
Data Furnishing Method: Clear window and thermometer
Buyers Products Company (9X737)

Quote

LF-100
LF100
6680-01-023-5027Meter, gas Volume, dry TestSpecial Features: Non-linear mass type, 0 to 100 cc per minute standard range, power 115 V ac, 50/60 hz, 15 watts, dc output recording signal
Teledyne Instruments Inc. (07682)

Quote

LF10K 6680-00-559-1327Meter, gas Volume, dry TestSpecial Features: Operates 0N 115 vac, 50/60 hz, 15 watts, solid state meter circuitry, dc output signal for recording, indicator size 7-3/4 in. by 5-3/4 in. by 5-3/4 in.gas flow temps up to 100 deg C, ambient temp from 0/40 deg C, transducer type, 8 ft long power and transducer cables, range std 0/10, 000 cc per minute
Teledyne Instruments Inc. (07682)

Quote

LF1K 6680-00-559-1329Meter, gas Volume, dry TestSpecial Features: Operates on 115 volts ac, 50 to 60 hz, 15 watts, solid state meter circuitry, dc output signal for recording, indicator size 7-3/4 in. X 5-3/4 in., gas flow temperatures up to 100 deg. C, ambient temperatures from 0 to 40 deg. C, transducer type, with 8 ft. lg. power and transducer cables, range standard 0 to 1000 cc per minute
Teledyne Instruments Inc. (07682)

Quote

LF-20K
LF20K
6680-01-004-6611Meter, gas Volume, dry TestSpecial Features: Ooperates on 115 volts ac, 50 to 60 hz, 15 watts, solid state meter circuitry, dc output signal for recording, indicator size 7-3/4 in. X 5-3/4 in. X 5-3/4 in., transducer type, standard range 0 to 20000 cc per minute
Teledyne Instruments Inc. (07682)

Quote

LF-2K
LF2K
6680-01-004-6613Meter, gas Volume, dry TestSpecial Features: 7OPERATES on 115 volts ac, 50 to 60 hz, 15 watts, solid state meter circuitry, dc output signal for recording, indicator size 7-3/4 X 5-3/4 X 5-3/4 in., gas flow temperatures up to 100 deg. C, transducer type, standard range 0 to 20000 cc per minute
Teledyne Instruments Inc. (07682)

Quote

LF300 6680-00-559-1328Meter, gas Volume, dry TestSpecial Features: Operates on 115 volt ac, 50 to 60 hz, 15 watts, solid state meter circuitry, dc output signal for recording, indicator size 7-3/4 in. X 5-3/4 in. X 5-3/4 in., gas flow temperatures up to 100 deg. C, ambient temperatures from 0 to 40 deg. C, transducer type, with 8 ft. lg. power and transducer cables, range standard 0 to 300 cc per minute
Teledyne Instruments Inc. (07682)

Quote

LF-5K
LF5K
6680-01-004-6612Meter, gas Volume, dry TestSpecial Features: Low flow rate measurement, readable to 0.5 % of range, accurate within 2 % from 0.1 pisa to 250 psig, transducer completely external to flow system, solid state meter circuitry, non-liner, recordable dc output signal, 0 to 5000 cc/min flow range, thermal operating technique, temp range, up to 100 deg. C, ambient temp, 0 to 40 deg. C, calibrated for air only, 115 volts ac, 50/60 cycles, 15 watts, dim., 7.75 X 5.75 X 5.75 in., 0.1 psias to 250 psig operating pressures, up to 100 deg. C flow temp, ambient temp 0 to 40 deg. C, 0.5 % full scale sensitivity, response time approx. 30 sec., output approx. 0-3 milli V dc into high impedence, monel construction
Reference Number Differentiating Characteristics: As differentiated by the material
Teledyne Instruments Inc. (07682)

Quote

LF6-0
LF60
6680-00-062-9875Transmitter, Rate of FlowSpecial Features: Flowrange based on MIL-F-7024, type ii, at 80.0 deg F
Overall Length: 2.219 inches nominal
Mounting Method: In-line
Ametek Inc. (53553)

Quote

LF6-00
LF600
6680-00-103-0165Transmitter, Rate of FlowEND Item Identification: Test stand fuel nozzle mfr code 07482, part no. 1C5853G01
Ametek Inc. (53553)
Schutte & Koerting Acquisition (0E3N0)

Quote

LF 6-000
LF6000
6680-01-345-2111Meter, Fluid Flow Indicating, DiffCapacity Rating: O.007 to 0.075 gal per min
Ametek Inc. (53553)

Quote

LF6-1
LF61
6680-00-086-1378Transmitter, Rate of FlowFSC Application Data: Test stand gas turbine, fsn 4920-490-2593, 407L system
Ametek Inc. (53553)

Quote

LF6-2
LF62
6680-00-403-0248Transmitter, Rate of FlowEND Item Identification: TF39 acft engine test stand
Special Features: Accuracy of reading within 0.5%;PRESSURE rating at 75 deg F 6000 psi;response time 20-30 seconds;flow range per hour 13.2 to 285 lbs
Overall Length: 2.219 inches nominal
Ametek Inc. (53553)
Schutte & Koerting Acquisition (0E3N0)

Quote

LF6-3
LF63
6680-00-103-0166Transmitter, Rate of FlowEND Item Identification: Test stand fuel nozzle mfr code 07482, part no. 1C5853G01
Ametek Inc. (53553)

Quote

LFA-303KLX
LFA303KLX
6680-01-083-0913Amplifier, Range ExtenderGeneral Characteristics Item Description: Explosion proof housing
FTI Flow Technology Inc. (18316)

Quote