Hazard-Detecting Instruments and Apparatus: R503D, RACR-100 CUP, RADEYE PRD
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
R503D | 6665-00-674-2871 | Shaft | Leeds and Northrup Co. (31922) | ||
R504B | 6665-00-700-7906 | ROD | Leeds and Northrup Co. (31922) | ||
R504D | 6665-00-675-4510 | Clip, Metal, Pen | Leeds and Northrup Co. (31922) | ||
R504E | 6665-00-700-7902 | Clamp | Leeds and Northrup Co. (31922) | ||
R59-08-03 R590803 | 6665-01-322-2248 | Card, Reflector | BRK Brands Inc. (56914) | ||
R604G | 6665-00-690-8406 | Stopper, Rubber | Leeds and Northrup Co. (31922) | ||
R815AW | 6665-00-700-7837 | Clip and Stud | Leeds and Northrup Co. (31922) | ||
R815BD | 6665-00-700-7843 | Insulator, Shield | Leeds and Northrup Co. (31922) | ||
R815C | 6665-00-700-7834 | Arm, Slidewire | Leeds and Northrup Co. (31922) | ||
R815M | 6665-00-700-7840 | Disk, Insulating | Leeds and Northrup Co. (31922) | ||
RACR-100 CUP RACR100CUP | 6665-01-041-9844 | Indicator, Radiac | Special Features: 7 digit 7 segment incandsecent display, 2 overflow indicators;reset button;temp range -5/+60 deg C;9D batteries;replaceable 2.46 ft cable;alum hsg | Alphanuclear Co. (37968) | |
RAD-60 RAD60 | 6665-01-499-0683 | Radiacmeter | Overall Length: 78.0 millimeters nominal Overall Height: 22.0 millimeters nominal Overall Width: 67.0 millimeters nominal | Rados Technology Inc. (04KU1) | |
RAD7 | 6665-01-564-5014 | Monitor, Chemical Agent | Special Features: Measures both radon and thoron Detecting Element Type: Electroscope Case Material: Plastic | Durridge Company Inc. (3PBL5) | |
RAD7 | 6665-01-571-8956 | Detector, gas | Special Features: Continuous monitoring; rapid response and recovery; simultaneous sniffing for both radon and thoron Overall Length: 10.500 inches nominal Overall Width: 7.500 inches nominal | Savantech (3BPL5) | |
RADCAL 10X5-180 RADCAL10X5180 | 6665-01-515-7777 | Detector, Radiac | Special Features: Chamber overview-roentgens rate resolution 0.1 mr/hr; max 1.7 kr/hr; dose resolution 0.01 ur; max 2.3 kr; rate specifications 0.1 MR/HR-1.7 R/hr; 1UGY/HR-15 gy/hr; exposure specifications 0.01 UR-2.3 kr; 0.1 NGY-20 gy; calibration accuracy porm 4 pct using X-rays at 150 kvp and 10.2 mm ai hvl; exposure rate dependence porm 5 pct, 20 mr/hr to 2000 R/hr; energy dependence porm 5 pct, 33 kev to 1.33 mev, with build-up material; construction polycarbonate walls and electrode; conducting graphite exterior coating; 180 CM3 active volume; 0.11 kg Functional Description: Designed for leakage measurementsas described in regulations for the addministration and enforcement of the radiation control for health and safetyact of 1968 and provides the required effective cross-section of 100 CM2 Supplementary Features: Controlling agency nomenclature leakage and low level measurement chamber | Radcal Corporation AN M D H Company (4P061) | |
RADCAL 9010 RADCAL9010 | 6665-01-515-7846 | Radiac set | Special Features: Dfunctions auto zero; dose rate; max dose rate; dose; auto dose; pulsed, cine;lcd display test lcd display verification; battery test checks battery voltage; chamber voltage test checks bias voltage Radiation Type AND Function: X-rays detects Indicator Type: Visual | Radcal Corporation AN M D H Company (4P061) | |
RADCAL 9060 RADCAL9060 | 6665-01-515-7849 | Radiac set Subassembly | Radcal Corporation AN M D H Company (4P061) | ||
RADCAL 9095 RADCAL9095 | 6665-01-549-4943 | Analyzer, Multi-Purpose | Special Features: Measures dose, dose rate, kv, time and ma or mas; fluoroscopic pulse rate and dose per pulse operation; single and multiple function measurements; high sensitivity; accuracy for cr readers with filtration and for mini C-arms; autoranging; ion chamber basic physics technology | Radcal Corporation AN M D H Company (4P061) | |
RADCAL 90C5-6 RADCAL90C56 | 6665-01-515-7848 | Radiac set Subassembly | Radcal Corporation AN M D H Company (4P061) | ||
RADEYE AB100 RADEYEAB100 | 6665-01-574-9839 | Indicator, Radiac | Special Features: Surface contamination meter with alpha/beta discrimination; scaler/timer with preset count, preset time for sample measurements; continuous ratemeter mode; alpha, beta, and alpha + beta modes; gross or net counting; approx. 1000 H operation time using 2 C batteries, rechargeable nimh batteries can be used; backlit lcd display; audible indication: single pulse for alpha, chirper mode for beta, proportional to count rate; earphone output; approx. wt: 2 lb; window thickness: 0.87 mg per cubic cm aluminized plastic film; sensitive area: 2.71 X 5.71 in Part Name Assigned BY Controlling Agency: Radeye AB100 contamination monitor Current Type: DC | Thermo Eberline LLC (52GB6) | |
RADEYE PRD RADEYEPRD | 6665-01-550-1027 | Radiacmeter | Part Name Assigned BY Controlling Agency: High sensitivity personal radiation detector Radiation Type AND Function: Gamma rays detects Radiation Type AND Function: Gamma rays measures | Thermo Electron Corp. (25468) |