Hazard-Detecting Instruments and Apparatus: K-1105C, K-5005N, KE75A-OF-CHL-01

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
K-1105C
K1105C
6665-00-542-6615Test kit, Boiler Water, PhosphateGeneral Characteristics Item Description: Cconsists of carrying case, slides, base, stannous chloride power, molybdate reagent, dispenser cap, test tube brush, filter paper, plastic funnel, 12 oz. spring scale, 17 oz. spring scale and A midget lamp
Taylor Technologies Inc. (89975)

Quote

K112J352REV1PT1 6665-00-316-1089Amplifier, TriggerGeneral Electric Co. (24446)

Quote

K112J353REV1PT1 6665-00-315-2322Amplifier, TriggerGeneral Electric Co. (24446)

Quote

K135 6665-00-171-9782Charger, Radiac DetectorEND Item Identification: Type AN/PDR-3A
Overall Length: 5.313 inches nominal
Overall Width: 4.938 inches nominal
GE Medical Systems (F0179)

Quote

K151 6665-00-263-3943RadiacmeterEND Item Identification: Type AN/PDR-3A
Radiation Type AND Function: Gamma rays measures
Radiation Type AND Function: X-rays measures
GE Medical Systems (F0179)

Quote

K-20M
K20M
6665-01-264-2246Alarm, gas, AutomaticEND Item Identification: Alarm gas automatic 6665-01-225-3233
Indicator Type: Horn and red light
Media Detected: Oxygen and combustible gas and hydrogen sulfide
Enmet Corporation (57529)

Quote

K21-001/K21-002
K21001K21002
6665-01-372-4383Calibrator set, RadiacSpecial Features: 3TOP dimensions 63.5 cm long by 25.4 cm wide; table travel 51 cm; rate of travel 0.0 to 1.5 cm/s; resolution positioning table in 0.25 cm increments; table capacity 23 kg; material machined cast aluminum tooling plate; overall dimensions 10 inches wide by 25 inches long; circular connector; home sensor; point base leveling screws; sized for 14 inches wide by 17 inches long plate; precision ground lead screwshaft; 3 point base leveling screws sized for 14 by 17 inch plate; includes stepper motor
END Item Identification: PMEL
Functional Description: The translation table is designedto support the survey meters and automatically position them during calibration. the table will accommodate up to five meters and allow the operator by remote control to sequentially move each meter inti aligment with the centerline of the radiation exposure systm
Pond Engineering Laboratories Inc. (0GSC6)

Quote

K-2500
K2500
6665-01-538-6457Detection System, Biological AgenPart Name Assigned BY Controlling Agency: Protein screening kit
Alexeter Technologies LLC (1SZK0)

Quote

K2500 6665-00-242-9567Detector, OxygenSpecial Features: Oxygen content is read directly on the meter; includes self-generating electrolytic cell; cell life 1 year; accuracy 0.25 to 3.0 percent
Overall Length: 3.000 inches nominal
Overall Width: 4.375 inches nominal
Bacharach Inc. (05083)
Wesco Distribution Inc. 5105 (1QTP5)

Quote

K300-0252-00
K300025200
6665-01-394-0148Detector, gasSpecial Features: Oxygen/flammable, carbon dioxide/hydrogen sulfide detection; alarms; instantaneous, time weighted average and short term exposure limit; includes: nicad batteries, carrying case, calibration tool, allen keys (2), aspirator, earphone, harness, belt-clip, user card and manual.
Detecting Element Detachability: Detachable
Zellweger Analytics (65194)

Quote

K350 6665-00-188-5555Indicator, RadiacSpecial Features: 10 in. lg, 6 in. W, 5 in. H;3.75 in. dia DIAL;20 ma signal amplitude fro full deflection;presentation Q/50, 000 milliroentgen U per hr W/1, 5, 10, 50, 100, 1000, 10, 000 markings;power rqmts 1.5V 300MA, 3V 30MA, 2V 0/.02MA, 46.8V 0.42MA, 23.4V 0.018MA;ACCESSORIES 1 allen wrench and war dept tech manual no. TM11-5514;LIGHTING for night operations, lever operated range scale, radiac training set
Nondefinitive Spec/STD Data: AN/PDR-T1 type
GE Medical Systems (F0179)

Quote

K-3925
K3925
6665-01-576-8111Water Testing kit, Chemical AgentSpecial Features: 25-250 ppm
END Item Identification: Rcr for navsses, boiler
Part Name Assigned BY Controlling Agency: Reagent, set, water titret
Chemetrics Inc. (7K791)

Quote

K-5005N
K5005N
6665-01-319-3149Test kit, ControlledEND Item Identification: Chem X equip-hydrazine bor/fdwtr test X treatment
Chemetrics Inc. (7K791)

Quote

K5010N W/H-100
K5010NWH100
6665-01-319-3149Test kit, ControlledEND Item Identification: Chem X equip-hydrazine bor/fdwtr test X treatment
Chemetrics Inc. (7K791)

Quote

K600-0177-04
K600017704
6665-01-356-8241Kit, Aspirator PumpEND Item Identification: Used on exotox gas detector
General Characteristics Item Description: Operating temperature minus 4 deg. to plus 104 deg. f; humidity 0 to 99 pct. rh; drift .6 to 1.5 pct of span over 200 days; battery life 10 to 14 hrs. from full charge
Zellweger Analytics (65194)

Quote

K-80
K80
6665-01-292-5455Detector kit, gasEnmet Corporation (57529)

Quote

KB-3
KB3
6665-01-101-3701Kit, Arson InvestigationPart Name Assigned BY Controlling Agency: Combination arson investigation kit
General Characteristics Item Description: Item consists of the model 400 hydrocarbon analyzer which is used to detect the presence of accelerants of less than 50 parts per million, the model 400 is powered by A rechargeable battery that can be recharged with provided wall plug charger; kit also includes model B-1 electronic nose detector, walking cane sniffer, accessory aids; all items housed in deluxe attache case
Grace Industries, Inc. (58944)

Quote

KC-2
KC2
6665-01-279-1607Indicator, Carbon MonoxideSpecial Features: Consists of hydrocarbon analzer, electronic nose detector, walking canesniffer, accesory aids housed in A attache case
Grace Industries, Inc. (58944)

Quote

K-D DELUXE DETECTOR TUBE PUMP
KDDELUXEDETECTORTUBEPUMP
6665-01-429-8592Sampling PumpPart Name Assigned BY Controlling Agency: Sampling pump W/end of stroke indicator remote sampling adapter
Special Features: With end-of-stroke indicator; remote sampling adapter; carrying pouch; pump provides user ability to obtain a precise 100ML sample volume to allow detection of gases and vapors; for use in air force to number: 907A and 911A
General Characteristics Item Description: With end-of-stroke indicator; remote sampling adapter; carrying pouch; pump provides user ability to obtain a precise 100ML sample volume to allow detection of gases and vapors; for use in air force to number: 907A and 911A
Mine Safety Appliances Company (55799)

Quote

KE75A-OF-CHL-01
KE75AOFCHL01
6665-01-384-5224Detector, gasSpecial Features: Exotox 75; standard oxygen/flamable; carbon dioxide/hydrogen sulfide/chlorine detection; built-in electric pump
Cable: Not included
Connector: Included
Zellweger Analytics (65194)

Quote

  • We solve sourcing challenges for K-1105C, K112J352REV1PT1, K135, K151, K-20M, K21-001/K21-002, K-5005N, K5010N W/H-100, KC-2, KE75A-OF-CHL-01 - NSN parts, hard to find, long lead time and obsolete components.