Hazard-Detecting Instruments and Apparatus: GR135ND, GSM-10SM, H3-C200-A
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
GR135ND | 6665-01-573-1738 | Indicator, Radiac | Special Features: Capable of detecting and identifying gamma and neutron sources; docking station; carrying case; performs three functions: survey (locate radioactive source), measure dose (determine exposure hazard level), and analyze (identify nuclides for risk assessment); back-lit display shows real-time count, count rate, and dose rate in numeric and graphic format; energy range: 20 kev to 3.0 mev; data storage: 40000 dose samples, 185 spectrum samples; operating temperature: 14 to 122 deg f; battery life (continuous operation): 8 hrs (rechargeable), 12 hrs (alkaline) Part Name Assigned BY Controlling Agency: Exploranium GR-135 plus identifier radioactive isotope identification device Width: 4.000 inches nominal | Science Applications International (79343) | |
GR3019 | 6665-01-550-8545 | Detector, Germanium | Special Features: Detector, germanium with shipping cases; also includes the following, 1EA P/n: CP-5SL cryo pulse 5; 1EA pn/cbif X13129-5 panasonice toughbook (model 29) W/X13129-6 optical drive; 1EA P/n: isoxcal; 1EA P/n: 1300 inspector 2000 mca; 1EA P/n: S520C GENIE-2000 software; Part Name Assigned BY Controlling Agency: Detector germanium with shipping cases Accessory Components AND Quantity: CP-5SL cryo pulse 5, 1EA; pn/cbif X13129-5 panasonice toughbook (model 29) W/X13129-6 optical drive, 1EA; isoxcal, 1EA; 1300 inspector 2000 mca, 1EA; S520C GENIE-2000 software, 1EA | Canberra Industries Inc. (24114) | |
GR3519 | 6665-01-516-2319 | Coaxial ge Detector | Criticality Code Justification: ZZZY Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications | Canberra Industries Inc. (18165) | |
GR460-4 GR4604 | 6665-01-585-6040 | Radiac set | Special Features: Measures gamma radiation levels; identifies A variety of radionuclides; designed for use on land and in the air; real-time wireless transmission; real-time recording and playback; geographical mapping capabilities; can be operated by untrained personnel or operate unattended Part Name Assigned BY Controlling Agency: Radiac meter gamma Radiation Type AND Function: Gamma rays measures | Science Applications International (52302) | |
GSM-10SM GSM10SM | 6665-01-281-9638 | Radiacmeter | END Item Identification: Hazard-detecting instruments and apparatus | B Johnson William & Associates Inc. (14835) | |
GSP-100 GSP100 | 6665-01-592-6243 | Probe, Radiac | Special Features: Gamma scintillation probe; aluminum housing; detector: scintillator- nai(ti); range: up to 5 milliroentgens per hour or up to 50, 000 cps; input power: +/- 5V dc; weight: approx. 4 lb; connector: 7 pin; mating connector included Part Name Assigned BY Controlling Agency: Probe scintillation gsp 100 Radiation Type AND Function: Gamma rays detects | Canberra Industries Inc. (24114) | |
GTP-172 GTP172 | 6665-01-005-4490 | Aircraft Fuel Sampling kit | Special Features: Military modify General Characteristics Item Description: C/O A housing W/flushing valve, syringe, sampling probe, quick disconnect coupler, reducing bushing 3/8 male to 1/4 female npt, reducing bushing 1/2 male to 1/4 female npt, coupling, pipe 1/4 female to 1/4 female npt, flushing and sampling hose, bypass hose, bypass tee, 6 plastic field monitors, carrying case | Gammon Technical Products (32218) | |
GTP-172 GTP172 | 6665-01-230-2652 | Monitor kit, Fuel Sampling | General Characteristics Item Description: Includes selector valve bypass tee, and bypass quick disconnect and hose assembly; sampling probe; carrying case; stainless steel parts; 4.0 lb | Gammon Technical Products (32218) | |
GTP-172M GTP172M | 6665-00-496-9623 | Kit, Fuel Sampling | End Item Identification: 66405382736 FSC Application Data: Mobile petroleum laboratory | Gammon Technical Products (32218) | |
GTP-172 MARK II GTP172MARKII | 6665-01-230-2652 | Monitor kit, Fuel Sampling | General Characteristics Item Description: Includes selector valve bypass tee, and bypass quick disconnect and hose assembly; sampling probe; carrying case; stainless steel parts; 4.0 lb | Gammon Technical Products (32218) | |
GTP25 | 6665-00-235-3820 | Detector pad, Free Water | General Characteristics Item Description: 25MM diameter, 50 pads per package; for use with aqua-glo water detector in measurement of undissolved water in aviation turbine fuels | Gammon Technical Products (32218) | |
GTP-3772 GTP3772 | 6665-01-462-8245 | Detector pad, Free W | Part Name Assigned BY Controlling Agency: Detcetor pad 50S General Characteristics Item Description: White; smooth, 47MM dia; coated on one side with uranine; unit issue pg of 50 | Gammon Technical Products (32218) | |
GUV-15H GUV15H | 6665-01-462-4031 | Sampling System, Air, Volumetric F | Special Features: Pm 10 system; C/o: GBM2360 blower motor assembly; G10474V filter holder; G10557PM 10 volumetric flow controller with flow look-up table; G302 digital timer with elapsed time indicator; G105 continuous flow recorder; G15015 water manometer; G1200 size selective inlet; G3000 filter paper cartridge; G10475 anodized aluminum shelter Part Name Assigned BY Controlling Agency: Sampling system air pm 10 system | Thermo Environmental Instruments (0HTS3) | |
GV0-3001-WTK GV03001WTK | 6665-01-600-8910 | Indicator, Combustible gas, Portab | Special Features: Replaces P/N 009-3001-01N (nsn 6665-01-457-0472) which is not in compliance with the trade agreement act; meets requirement at intermediate and organizational maintenance levels to purge A/C fuel cells and tanks free of jet fuel vapors prior to inspection or repair; combustible gas and oxygen indicator required to endure air does not contain explosive levels of fuel vapors or insufficient amounts of oxygen END Item Identification: G0CMS common support equipment; special tool and support equip Part Name Assigned BY Controlling Agency: Inavy: gas monitor, navy wing tank entry | RAE Systems Inc. (06JB6) | |
GV-100 GV100 | 6665-01-498-8927 | Pump, gas Sampling | Special Features: Nprecisely collects A sample volume for A detector tube; full stroke (100ML) and half STROKE(50ML) positions are marked exactly by the red line on prime shaft; handle precisely locks at those positions; weighs 230G Part Name Assigned BY Controlling Agency: Pump gas sampling collects sample volume for detector tube | Instrument Depot Inc. (0NWP4) | |
GV-100S GV100S | 6665-01-495-9611 | Pump, Air Sampling | Special Features: Fas sampling pump, precisely collects A sample volume for A detector tube; full stroke (100ML) and half stroke (50ML) positions are marked exactly by the red line on the pump shaft, handle precisely locks at these positions;calibrated based upon A prescribed (standard) volume of sample;detects and quantifies A large number of gases and gaseous compounds, non-sparking design, attached flow finish indicator tells you when stroke is complete; weighs 230G Part Name Assigned BY Controlling Agency: Pump air sampling precisely collects sample volume F/detector tu | Instrument Depot Inc. (0NWP4) | |
GVC-1160-000 GVC1160000 | 6665-01-462-2236 | Detector, gas | End Item Identification: Special tool and support equipment | RAE Systems Inc. (06JB6) | |
H | 6665-01-020-1966 | Indicator, Combustible gas, Portab | Special Features: Designed for natural gas;scale PRESENTATION-0 to 100 pct gas;dilution valve included;multiple calibration feature included | Bacharach Inc. (05083) | |
H25C02 | 6665-01-473-2038 | Monitor, Chemical Agent | Criticality Code Justification: ZZZY Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications | Yokogawa Corporation of America (60336) | |
H25C1N5NEP3 | 6665-01-467-1239 | Detector kit, Cbr Agents | Criticality Code Justification: ZZZY Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications | Yokogawa Corporation of America (60336) | |
H3-C200-A H3C200A | 6665-01-618-3565 | Tritium Column | Special Features: Tritium columns for liquid scintillator counter, lsc, water sample preparation; designed to replace distillation for most routine tritium analyses of aqueous samples; removes potential interferences in the lsc spectrum, just as distillation does; not intended to be an enrichment procedure; should only be used in situations when required detection limit can be achieved by direct counting of A 5-10 ml aliquot of sample, plus cocktail, processed through column; component: diphonix resin, target: cations, capacity: 0.8 meq; component: anion exchange resin, target: anions, capacity: 0.8 meq, component: polymethacrylate resin, target: organic molecules, capacity: 50 mg; package of 200 Part Name Assigned BY Controlling Agency: Tritium column 75-150U 2ML 200S | Eichrom Technologies LLC (1H4S1) |