MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
GR135ND 6665-01-573-1738Indicator, RadiacSpecial Features: Capable of detecting and identifying gamma and neutron sources; docking station; carrying case; performs three functions: survey (locate radioactive source), measure dose (determine exposure hazard level), and analyze (identify nuclides for risk assessment); back-lit display shows real-time count, count rate, and dose rate in numeric and graphic format; energy range: 20 kev to 3.0 mev; data storage: 40000 dose samples, 185 spectrum samples; operating temperature: 14 to 122 deg f; battery life (continuous operation): 8 hrs (rechargeable), 12 hrs (alkaline)
Part Name Assigned BY Controlling Agency: Exploranium GR-135 plus identifier radioactive isotope identification device
Width: 4.000 inches nominal
Science Applications International (79343)

Quote

GR3019 6665-01-550-8545Detector, GermaniumSpecial Features: Detector, germanium with shipping cases; also includes the following, 1EA P/n: CP-5SL cryo pulse 5; 1EA pn/cbif X13129-5 panasonice toughbook (model 29) W/X13129-6 optical drive; 1EA P/n: isoxcal; 1EA P/n: 1300 inspector 2000 mca; 1EA P/n: S520C GENIE-2000 software;
Part Name Assigned BY Controlling Agency: Detector germanium with shipping cases
Accessory Components AND Quantity: CP-5SL cryo pulse 5, 1EA; pn/cbif X13129-5 panasonice toughbook (model 29) W/X13129-6 optical drive, 1EA; isoxcal, 1EA; 1300 inspector 2000 mca, 1EA; S520C GENIE-2000 software, 1EA
Canberra Industries Inc. (24114)

Quote

GR3519 6665-01-516-2319Coaxial ge DetectorCriticality Code Justification: ZZZY
Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications
Canberra Industries Inc. (18165)

Quote

GR460-4
GR4604
6665-01-585-6040Radiac setSpecial Features: Measures gamma radiation levels; identifies A variety of radionuclides; designed for use on land and in the air; real-time wireless transmission; real-time recording and playback; geographical mapping capabilities; can be operated by untrained personnel or operate unattended
Part Name Assigned BY Controlling Agency: Radiac meter gamma
Radiation Type AND Function: Gamma rays measures
Science Applications International (52302)

Quote

GSM-10SM
GSM10SM
6665-01-281-9638RadiacmeterEND Item Identification: Hazard-detecting instruments and apparatus
B Johnson William & Associates Inc. (14835)

Quote

GSP-100
GSP100
6665-01-592-6243Probe, RadiacSpecial Features: Gamma scintillation probe; aluminum housing; detector: scintillator- nai(ti); range: up to 5 milliroentgens per hour or up to 50, 000 cps; input power: +/- 5V dc; weight: approx. 4 lb; connector: 7 pin; mating connector included
Part Name Assigned BY Controlling Agency: Probe scintillation gsp 100
Radiation Type AND Function: Gamma rays detects
Canberra Industries Inc. (24114)

Quote

GTP-172
GTP172
6665-01-005-4490Aircraft Fuel Sampling kitSpecial Features: Military modify
General Characteristics Item Description: C/O A housing W/flushing valve, syringe, sampling probe, quick disconnect coupler, reducing bushing 3/8 male to 1/4 female npt, reducing bushing 1/2 male to 1/4 female npt, coupling, pipe 1/4 female to 1/4 female npt, flushing and sampling hose, bypass hose, bypass tee, 6 plastic field monitors, carrying case
Gammon Technical Products (32218)

Quote

GTP-172
GTP172
6665-01-230-2652Monitor kit, Fuel SamplingGeneral Characteristics Item Description: Includes selector valve bypass tee, and bypass quick disconnect and hose assembly; sampling probe; carrying case; stainless steel parts; 4.0 lb
Gammon Technical Products (32218)

Quote

GTP-172M
GTP172M
6665-00-496-9623Kit, Fuel SamplingEnd Item Identification: 66405382736
FSC Application Data: Mobile petroleum laboratory
Gammon Technical Products (32218)

Quote

GTP-172 MARK II
GTP172MARKII
6665-01-230-2652Monitor kit, Fuel SamplingGeneral Characteristics Item Description: Includes selector valve bypass tee, and bypass quick disconnect and hose assembly; sampling probe; carrying case; stainless steel parts; 4.0 lb
Gammon Technical Products (32218)

Quote

GTP25 6665-00-235-3820Detector pad, Free WaterGeneral Characteristics Item Description: 25MM diameter, 50 pads per package; for use with aqua-glo water detector in measurement of undissolved water in aviation turbine fuels
Gammon Technical Products (32218)

Quote

GTP-3772
GTP3772
6665-01-462-8245Detector pad, Free WPart Name Assigned BY Controlling Agency: Detcetor pad 50S
General Characteristics Item Description: White; smooth, 47MM dia; coated on one side with uranine; unit issue pg of 50
Gammon Technical Products (32218)

Quote

GUV-15H
GUV15H
6665-01-462-4031Sampling System, Air, Volumetric FSpecial Features: Pm 10 system; C/o: GBM2360 blower motor assembly; G10474V filter holder; G10557PM 10 volumetric flow controller with flow look-up table; G302 digital timer with elapsed time indicator; G105 continuous flow recorder; G15015 water manometer; G1200 size selective inlet; G3000 filter paper cartridge; G10475 anodized aluminum shelter
Part Name Assigned BY Controlling Agency: Sampling system air pm 10 system
Thermo Environmental Instruments (0HTS3)

Quote

GV0-3001-WTK
GV03001WTK
6665-01-600-8910Indicator, Combustible gas, PortabSpecial Features: Replaces P/N 009-3001-01N (nsn 6665-01-457-0472) which is not in compliance with the trade agreement act; meets requirement at intermediate and organizational maintenance levels to purge A/C fuel cells and tanks free of jet fuel vapors prior to inspection or repair; combustible gas and oxygen indicator required to endure air does not contain explosive levels of fuel vapors or insufficient amounts of oxygen
END Item Identification: G0CMS common support equipment; special tool and support equip
Part Name Assigned BY Controlling Agency: Inavy: gas monitor, navy wing tank entry
RAE Systems Inc. (06JB6)

Quote

GV-100
GV100
6665-01-498-8927Pump, gas SamplingSpecial Features: Nprecisely collects A sample volume for A detector tube; full stroke (100ML) and half STROKE(50ML) positions are marked exactly by the red line on prime shaft; handle precisely locks at those positions; weighs 230G
Part Name Assigned BY Controlling Agency: Pump gas sampling collects sample volume for detector tube
Instrument Depot Inc. (0NWP4)

Quote

GV-100S
GV100S
6665-01-495-9611Pump, Air SamplingSpecial Features: Fas sampling pump, precisely collects A sample volume for A detector tube; full stroke (100ML) and half stroke (50ML) positions are marked exactly by the red line on the pump shaft, handle precisely locks at these positions;calibrated based upon A prescribed (standard) volume of sample;detects and quantifies A large number of gases and gaseous compounds, non-sparking design, attached flow finish indicator tells you when stroke is complete; weighs 230G
Part Name Assigned BY Controlling Agency: Pump air sampling precisely collects sample volume F/detector tu
Instrument Depot Inc. (0NWP4)

Quote

GVC-1160-000
GVC1160000
6665-01-462-2236Detector, gasEnd Item Identification: Special tool and support equipment
RAE Systems Inc. (06JB6)

Quote

H 6665-01-020-1966Indicator, Combustible gas, PortabSpecial Features: Designed for natural gas;scale PRESENTATION-0 to 100 pct gas;dilution valve included;multiple calibration feature included
Bacharach Inc. (05083)

Quote

H25C02 6665-01-473-2038Monitor, Chemical AgentCriticality Code Justification: ZZZY
Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications
Yokogawa Corporation of America (60336)

Quote

H25C1N5NEP3 6665-01-467-1239Detector kit, Cbr AgentsCriticality Code Justification: ZZZY
Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications
Yokogawa Corporation of America (60336)

Quote

H3-C200-A
H3C200A
6665-01-618-3565Tritium ColumnSpecial Features: Tritium columns for liquid scintillator counter, lsc, water sample preparation; designed to replace distillation for most routine tritium analyses of aqueous samples; removes potential interferences in the lsc spectrum, just as distillation does; not intended to be an enrichment procedure; should only be used in situations when required detection limit can be achieved by direct counting of A 5-10 ml aliquot of sample, plus cocktail, processed through column; component: diphonix resin, target: cations, capacity: 0.8 meq; component: anion exchange resin, target: anions, capacity: 0.8 meq, component: polymethacrylate resin, target: organic molecules, capacity: 50 mg; package of 200
Part Name Assigned BY Controlling Agency: Tritium column 75-150U 2ML 200S
Eichrom Technologies LLC (1H4S1)

Quote

  • We solve sourcing challenges for GR135ND, GR460-4, GSP-100, GTP-172, GTP-172 MARK II, GTP25, GV-100S, GVC-1160-000, H25C1N5NEP3, H3-C200-A - NSN parts, hard to find, long lead time and obsolete components.