Hazard-Detecting Instruments and Apparatus: F89J161, F89L150, F92C460

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
F89J161 6665-01-314-8928Monitor, FormaldehydePart Name Assigned BY Controlling Agency: Monitor formaldehyde analysis not included 5S
General Characteristics Item Description: A badge worn by medical personnel or placed on desk; measures formaldehyde in air; analysis not included; unit qty 5
Air Force Medical Logistics Office (66735)

Quote

F89L142 6665-01-315-4774Detector, gasSpecial Features: Ntl draeger benzene detector tube; provides gas/vapor concentration for safe work environment; used with portable hand bellows pump and quantimeter; unit qty 10
Air Force Medical Logistics Office (66735)

Quote

F89L144 6665-01-315-4775Detector, gasSpecial Features: Ntl draeger methylene chloride detector tube; provides gas/vapor concentration for safe work environment; used with portable bellows hand pump and quantimeter; unit qty 10
Air Force Medical Logistics Office (66735)

Quote

F89L145 6665-01-315-4773Detector, gasSpecial Features: Ntl draeger trichloroethane detector tube; provides gas/vapor concentration for safe work environment; used with portable bellows hand pump and quantimeter; unit qty 5
Part Name Assigned BY Controlling Agency: Gas detector 5S
Air Force Medical Logistics Office (66735)

Quote

F89L147 6665-01-315-4772Detector, gasSpecial Features: Ntl draeger chlorine detector tube; provides gas/vapor concentration for safe work environment; used with portable bellows hand pump and quantimeter; unit qty 10
Air Force Medical Logistics Office (66735)

Quote

F89L148 6665-01-315-1279Detector, gasSpecial Features: Ntl draeger ammonia detector tube; provides gas/vapor concentration reading for safe work environment; .5-700 measuring range; used with portable bellows hand pump and quantimeter; unit qty 10
Air Force Medical Logistics Office (66735)

Quote

F89L149 6665-01-315-1278Detector, gasSpecial Features: Ntl draeger methylethyl ketone detector tube; provides gas/vapor concentration reeading for safe work environment; 100-12000PPM measuring range; used with portable bellows hand pump and quantimeter; unit qty 10
Part Name Assigned BY Controlling Agency: Detector gas methylethyl ketone 10S
Air Force Medical Logistics Office (66735)

Quote

F89L150 6665-01-315-5367Detector, gasSpecial Features: Ntl draeger carbon monoxide detector tube; provides gas/vapor concentration reading F/safe work environment; .2-300PPM measuring range; used W/portable bellows hand pump and quantimeter; unit qty 10
Part Name Assigned BY Controlling Agency: Detector tube ntl draeger carbon monoxide 10S
Air Force Medical Logistics Office (66735)

Quote

F89L151 6665-01-315-1271Tube, Hydrogen Sulfide DetectorSpecial Features: Measuring range 0.5-75PPM;PROVIDES gas/vapor concentration readings;used W/portable bellows hand pump or quantimeter;unit qty 10
Air Force Medical Logistics Office (66735)

Quote

F89L153 6665-01-315-1277Detector, gasSpecial Features: Entl draeger formaldehyde detector tube; provides gas/vapor concentration reading for safe work environment; .5-10PPM measuring range; used W/portable bellows hand pump andd quantimeter; unit qty 10
Air Force Medical Logistics Office (66735)

Quote

F90H379 6665-01-331-5475Detector, gasSpecial Features: Vmethane grab sampling detector; contains A granular chemical layer enclosed in A glass tube W/break off tips; color change denotes chemical hazard; measuring range-qualitative; performs 5 tests; used W/draeger pump; P/N 800-26065
Overall Length: 114.0 millimeters nominal
Detecting Element Type: Chemical reaction
Air Force Medical Logistics Office (66735)

Quote

F91F282 6665-01-345-5353Cassette, gas DetectorPart Name Assigned BY Controlling Agency: Cassette gas detector non-toxic nitrogen dioxide W/vacuum pump
General Characteristics Item Description: Reel of chemically treated paper tape in plastic container; standard size; non-toxic; chemical reagent system that acts as both A trapping and analysis medium, detecting and measuring nanogram amounts of nitrogen dioxide; tape is fed through optical head of gas detector; pn TLD-1; detector has vacuum pump which draws in samples and filters through cassette
Air Force Medical Logistics Office (66735)

Quote

F91G150 6665-01-344-1157Detector, gasSpecial Features: Hermetically sealed glass tube; 6 inch long; filled with inert carrier material which has been impregnated with A reagent system designed to produce A colorimetric indication; measures methylene chloride levels 2000 ppm; osha pel 500 ppm; used with bellows pump, draegers model 31, P/N 6726065 for on the spot analysis; unit qty 10
Detecting Element Type: Chemical reaction
Case Material: Glass
Air Force Medical Logistics Office (66735)

Quote

F91G152 6665-01-344-1159Detector, gasSpecial Features: Hermetically sealed glass tube; 6 in. long; filled with inert carrier material which has been impregnated with A reagent system designed to produce A colorimetric indication; measures trichloroethylene levels 2-200 ppm; osha-pel 50 ppm; used with bellows pump, draegers model 31, P/N 6726065 for on the spot analysis; unit qty 10
Detecting Element Type: Chemical reaction
Case Material: Glass
Air Force Medical Logistics Office (66735)

Quote

F91G153 6665-01-345-5373Detector, gasSpecial Features: Hermeticall sealed glass tube; 6 in. long; filled W/inert carrier matl which has been impregnated W/A reagent system designed to produce A colorimetric indication; measures petroleum hydrocarbon levels 100-2500 ppm; used W/bellows pump, draegers P/N 6726065 for on the spot analysis; unit pkg qty 10
Detecting Element Type: Chemical reaction
Case Material: Glass
Air Force Medical Logistics Office (66735)

Quote

F91G155 6665-01-344-1158Detector, gasSpecial Features: Hermetically sealed glass tube; 6 inch long; filled with inert carrier matl which has been impregnated with A reagent system designed to produce A colorimetric indication; measures mercury vapor levels 0.1-2 MG/M3; osha pel's 0.05 MG/M3; used with bellows pump, draegers model 31, P/N 6726065 for on the spot analysis; unit qty 10
Detecting Element Type: Chemical reaction
Case Material: Glass
Air Force Medical Logistics Office (66735)

Quote

F91G157 6665-01-344-1156Detector, gasSpecial Features: Hermetically sealed glass tube; 6 inch long; filled with inert carrier matl which has been impregnated with A reagent system designed to produce A colorimetric indication; measures benzene levels 2-60 ppm; 0SHA-PEL 1 ppm; used with bellows poump, draegers model 31, P/N 6726065 for on the spot analysis; contains 5 prescrubber tubes and 5 sampling tubes
Detecting Element Type: Chemical reaction
Case Material: Glass
Air Force Medical Logistics Office (66735)

Quote

F91H109 6665-01-345-5374Detector, gasSpecial Features: Direct reading tube; calibration markings printed on tube; hermetically sealed; for on the spot air sample analysis; measures benzene 2.5-120 ppm; for use W/sensidyne/gastic piston pumps P/n's 7010657-1 standard or 7010790-1 W/flow finish indicator; unit pkg qty 10
Detecting Element Type: Chemical reaction
Case Material: Glass
Air Force Medical Logistics Office (66735)

Quote

F91K164 6665-01-353-3785Detector, gasSpecial Features: Graduated, direct-reading glass diffusion tube; carbon dioxide samples are taken at A constant rate and diffused into the tube where they undergo A colorimetric reaction; measures time-weighted average concentrations for periods up to 8 hours; on spot results; no instruments needed; 500 to 20, 000 ppm X h; 65 to 2, 500 ppm max during 8 hours
Overall Length: 5.000 inches nominal
Detecting Element Type: Chemical reaction
Air Force Medical Logistics Office (66735)

Quote

F92C460 6665-01-358-3869Detector, gasSpecial Features: Gacetone (lr) detector tube; hermetically sealed; break off tips; chemically filled to produce A colorimetric indication; measurable concentration range 50-12000DPM; used W/pump, model 800, pn 7010657-1
Overall Length: 4.500 inches nominal
Detecting Element Type: Chemical reaction
Air Force Medical Logistics Office (66735)

Quote

  • We solve sourcing challenges for F89J161, F89L142, F89L147, F89L148, F89L149, F90H379, F91G153, F91G155, F91H109, F92C460 - NSN parts, hard to find, long lead time and obsolete components.