MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
8101521-2 81015212 | 6665-01-010-7965 | Tube, gas Detector | III Part Name Assigned BY Controlling Agency: Tube box, phosgene 0.02/A0.02-1 ppm | Draeger Safety Inc. (53833) | |
810-15L 81015L | 6665-01-567-7613 | Indicator Tube, gas | Special Features: Gastec nitric acid detector tube 0.1-40PPM END Item Identification: Gastec GV-100 | SKC Inc. (55659) | |
810-16 81016 | 6665-01-567-9879 | Indicator Tube, gas | Special Features: Gastec phosgene detector tube, 0.05-20PPM END Item Identification: Gastec GV-100 Part Name Assigned BY Controlling Agency: Indicator tube, gas | SKC Inc. (55659) | |
810-163LL 810163LL | 6665-01-567-8477 | Indicator Tube, gas | Special Features: Gastec detector tube; 10 per pkg; factory calibrated; ethylene oxide sampler 0.4 to 350 ppm END Item Identification: Used on gastec GV100 piston style detector tube vapor/gas sampling pump, draws 100ML air sample | SKC Inc. (55659) | |
8101641 | 6665-01-395-5211 | Detector, gas | Special Features: Use for phenol gas END Item Identification: Dds life support Overall Length: 6.000 inches nominal | Draeger Safety Inc. (53833) | |
8101641-1 81016411 | 6665-01-395-5211 | Detector, gas | Special Features: Use for phenol gas END Item Identification: Dds life support Overall Length: 6.000 inches nominal | Draeger Safety Inc. (53833) | |
8101641-2 81016412 | 6665-01-395-5211 | Detector, gas | Special Features: Use for phenol gas END Item Identification: Dds life support Overall Length: 6.000 inches nominal | Draeger Safety Inc. (53833) | |
8101661 | 6665-01-458-5590 | Tube, Toluene | III Part Name Assigned BY Controlling Agency: Tube set, toluene 5/B General Characteristics Item Description: 50-300/5-80 ppm range | Draeger Safety Inc. (53833) | |
8101661-2 81016612 | 6665-01-458-5590 | Tube, Toluene | III Part Name Assigned BY Controlling Agency: Tube set, toluene 5/B General Characteristics Item Description: 50-300/5-80 ppm range | Draeger Safety Inc. (53833) | |
8101671-1 81016711 | 6665-01-395-5215 | Detector, gas | Special Features: Use for methylbromide gas END Item Identification: Dds life support Overall Length: 6.000 inches nominal | Draeger Safety Inc. (53833) | |
81 01 681 8101681 | 6665-01-588-0299 | Indicator Tube, gas | Special Features: Measuring range: 1 to 10 ppm; number of strokes: 10; colour change: blue to yellow Part Name Assigned BY Controlling Agency: Hydrochloric acid, nitric acid Operation Method: Hand operated | Draeger Safety Inc. (53833) | |
8101691 | 6665-01-391-4953 | Detector, gas | Detecting Element Type: Chemical reaction Special Features: Hermetically sealed glass tube used to measure petroleum hydrocarbons (n-octane); measuring range: 10-300 ppm; filled with inert carrier material which has been impregnated with a reagent designed to produce a colormetric indication; for use with draeger detector pump model 31 P/N 6726065 | Draeger Safety Inc. (53833) | |
810-17 81017 | 6665-01-567-8472 | Indicator Tube, gas | Special Features: Gastec detector tube; 10 per pkg; factory calibrated; hydrogen fluoride sampler 0.25 to 100 ppm END Item Identification: Used on gastec GV100 piston style detector tube vapor/gas sampling pump, draws 100ML air sample | SKC Inc. (55659) | |
8101701-1 81017011 | 6665-01-073-6527 | Tube, Toluene | III Part Name Assigned BY Controlling Agency: Tube box, toluene 50/A, 50-400 ppm General Characteristics Item Description: 50 ppm; 50-400 ppm range | Draeger Safety Inc. (53833) | |
8101701-2 81017012 | 6665-01-073-6527 | Tube, Toluene | III Part Name Assigned BY Controlling Agency: Tube box, toluene 50/A, 50-400 ppm General Characteristics Item Description: 50 ppm; 50-400 ppm range | Draeger Safety Inc. (53833) | |
8101711-1 81017111 | 6665-00-140-0886 | Detector Tube, Short Term | III Part Name Assigned BY Controlling Agency: Tube box, ammonia 0./25.A, 0.25-3 ppm Special Features: Used to detect ammonia; range 0.25 to 3 ppm General Characteristics Item Description: Ten tubes per box | Draeger Safety Inc. (53833) | |
810-172 810172 | 6665-01-567-7633 | Indicator Tube, gas | Special Features: Gastec ethylene detector tube 25-800PPM END Item Identification: Gastec GV-100 | SKC Inc. (55659) | |
8101721 | 6665-01-395-5213 | Detector, gas | Overall Length: 6.000 inches nominal Overall Width: 1.000 inches nominal Case Material: Glass | Draeger Safety Inc. (53833) | |
8101721-1 81017211 | 6665-01-395-5213 | Detector, gas | Overall Length: 6.000 inches nominal Overall Width: 1.000 inches nominal Case Material: Glass | Draeger Safety Inc. (53833) | |
8101731-1 81017311 | 6665-00-769-0944 | Tube, gas Detector | III Part Name Assigned BY Controlling Agency: Tube box toluene 100/A, 100-1, 800 ppm | Draeger Safety Inc. (53833) |