Hazard-Detecting Instruments and Apparatus: 6665NCM082985, 6665NCM116619, 6665NCM116622
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
6665NCM082985 | 6665-01-569-3988 | Water Test kit Accessories | Special Features: Includes: 4 oz bottle, 8 oz bottle, allen wrench and set screw kit, red grease marking pencil, filter forceps, filter holder assembly, sanitarians sampling cup, vacuum syringe, and tube assembly; for use W/ end item water test kit, bacteriological, 6665-00-682-4765 END Item Identification: 6665-00-682-4765 water test kit, bacteriological Part Name Assigned BY Controlling Agency: Water test kit | Defense Medical Standardization (64616) | |
6665NCM093325 | 6665-01-573-1738 | Indicator, Radiac | Special Features: Capable of detecting and identifying gamma and neutron sources; docking station; carrying case; performs three functions: survey (locate radioactive source), measure dose (determine exposure hazard level), and analyze (identify nuclides for risk assessment); back-lit display shows real-time count, count rate, and dose rate in numeric and graphic format; energy range: 20 kev to 3.0 mev; data storage: 40000 dose samples, 185 spectrum samples; operating temperature: 14 to 122 deg f; battery life (continuous operation): 8 hrs (rechargeable), 12 hrs (alkaline) Part Name Assigned BY Controlling Agency: Exploranium GR-135 plus identifier radioactive isotope identification device Width: 4.000 inches nominal | Defense Medical Standardization (64616) | |
6665NCM093447 | 6665-01-520-4633 | Filter, Water Trap | Special Features: Water trap filter with CONNECTOR-3PK; 2 metal connectors END Item Identification: 6665-01-536-7280 detector, gas Part Name Assigned BY Controlling Agency: External filters 3S | Defense Medical Standardization (64616) | |
6665NCM094064 | 6665-01-523-3163 | Detector, gas | Special Features: Interchangeable sensor END Item Identification: Multirae Part Name Assigned BY Controlling Agency: Hcn hydrogen cyanide sensor | Defense Medical Standardization (64616) | |
6665NCM104171 | 6665-01-520-4632 | Adapter, Calibration | Special Features: Pumped monitor calibration adapter END Item Identification: 6665-01-536-7280 detector, gas Part Name Assigned BY Controlling Agency: Adapter calibration pgm 50 | Defense Medical Standardization (64616) | |
6665NCM104201 | 6665-01-520-4630 | Probe, Inlet | Special Features: Probe inlet with 3IN polytetrafluoroethylene tubing END Item Identification: 6665-01-536-7280 detector, gas Part Name Assigned BY Controlling Agency: Probe inlet with 3 in polytetrafluoroethylene tubing; for use with end item detector, gas kit multirae plus, 6665-01-536-7280 | Defense Medical Standardization (64616) | |
6665NCM104294 | 6665-01-584-0738 | Radiacmeter | Special Features: Powered by single standard aa cell, either 1.5 V alkaline or 3.6 V lithium thionyl chloride for max battery life; pre-use integrity checks may be initiated over the infa-red communications link as part of the epd issue process of access control or dosimetry management systems; checks include: detector tests, battery test, and battery voltage read; single button control for display and function, recessed to prevent inadvertent operation Part Name Assigned BY Controlling Agency: Dosimeter personal electronic gamma beta and X-radiation detection Radiation Type AND Function: Beta rays detects | Defense Medical Standardization (64616) | |
6665NCM104671 | 6665-01-587-0702 | Indicator, Radiac | Special Features: Radioactive isotope identification device (riid), model 940; portable; functions: nuclide identification, spectrum analysis, dose rate calculation (rem/sv), total dose, audible search tool, data logging; detector: detector: 2X2 sodium iodide, lithium; energy range : 18 kev to 3 mev; power: 8 standard aa batteries; weight: 4.5 lb, incl. 2X2 in nai detector and batteries; temperatur range: -20 to +50 deg c; alarm: visual (on screen) and audio (internal speaker or optional headphones); calibration: automatic stabilization with temperature; controller display: 320 X 240 high brightness 32000 color 3.5 in transflective lcd display Part Name Assigned BY Controlling Agency: Model 940 radioactive isotope identification device surveillance and measurement (sam) Width: 5.000 inches nominal | Defense Medical Standardization (64616) | |
6665NCM104673 | 6665-01-587-1038 | Cable, Special, Multi Channel Anal | End Item Identification: 6665-01-587-0702 indicator, radiac Part Name Assigned BY Controlling Agency: Cable special digital signal processing mca detector Special Features: Special multi-channel analyzer (mca)/detector digital signal processing cable, lemo elbow 90; end item: sam 940 radioactive isotope identification device | Defense Medical Standardization (64616) | |
6665NCM104674 | 6665-01-587-1045 | Cable, Indicator, Radiac | Special Features: 5 foot detector extension cable; end item: sam 940 radioactive isotope identification device END Item Identification: 6665-01-587-0702 indicator, radiac Part Name Assigned BY Controlling Agency: Cable extension detector | Defense Medical Standardization (64616) | |
6665NCM104676 | 6665-01-587-1068 | Adapter, Indicator, Radiac | Special Features: Vehicle adapter; for use with end item sam 940 radioactive isotope identification device END Item Identification: 6665-01-587-0702 indicator, radiac Part Name Assigned BY Controlling Agency: Adapter vehicle sam 940 defender | Defense Medical Standardization (64616) | |
6665NCM104677 | 6665-01-587-1029 | Bag, Field Protection, Indicator, R | Special Features: Rugged field bag, dust and humidity protection; custom padded; clandestine field use; for use with sam 940 radiation isotope identification device END Item Identification: 6665-01-587-0702 indicator, radiac Part Name Assigned BY Controlling Agency: Bag rugged field protection radiation isotope identification device | Defense Medical Standardization (64616) | |
6665NCM104678 | 6665-01-587-1085 | Case, Storage and Transport, Indic | Special Features: Hard pelican case; specifically designed for sam model 940-2-GN and accessories; fitted with customized foam inserts; dimensions: 24 X 9 X 19 in END Item Identification: 6665-01-587-0702 indicator, radiac Part Name Assigned BY Controlling Agency: Hard pelican case sam 940-2-GN | Defense Medical Standardization (64616) | |
6665NCM104923 | 6665-01-587-7641 | Scintillator | Special Features: Capable of counting all radioisotopes, including tritium; sample types: lsc vials, microtubes, test tubes; detector: single-photon counting pmt; display: 2 X 16 character alpha-numeric lcd; energy range: 2 KEV-2000 kev; power: 110-240 vac, 12 vdc; approx. weight: 9 kg; liquid scintillation counting max. count rate: 2, 000, 000 cpm; gamma counting detector: 32 X 32 mm nai (ti) crystal (through-hole) Part Name Assigned BY Controlling Agency: Scintillator counter liquid gamma counter and luminometer triathler Overall Length: 12.992 inches nominal | Defense Medical Standardization (64616) | |
6665NCM105069 | 6665-01-588-4381 | Thermocycler | Special Features: Tests for the following targets, hazmat: anthrax, brucella spp, botulism A, coxiella, E. coli 0157, tularemia, ricin, salmonella, smallpox, and plague. food safety: campylobacter, L. monocytogenes, and salmonella. water safety: cryptosporidium target 1, E. coli 0157, and salmonella; size: 10 X 4.5 X 7.5; weight: 11 lb; rechargeable battery pack included with instrument; set up time: less than or equal to 5 minutes; temperature control, lower heater: 56 to 64 deg C, upper heater: 86 to 94 deg c; uniformity: 0.5 deg C in single sample, intersample 1 deg C across sample area; fluorescence acquisition: one color optics modules; external power supply: 24 vdc, 4 A output, 110-220 vac Part Name Assigned BY Controlling Agency: Razor ex Overall Length: 10.000 inches nominal | Defense Medical Standardization (64616) | |
6665NCM115922 | 6665-01-592-6375 | Holder, Radiac Sample | Special Features: For repeatable geometry counting of wipes, filter paper, or slides; sample size: 4 in diameter max; sample tray: selectable spacing of 0.125, 0.25, 0.5, 1, and 2 in from detector; dimensions: 6.5 in L X 6.2 in W X 3.5 in H Part Name Assigned BY Controlling Agency: Holder sample radiac Unpackaged Unit Weight: 2.700 pounds | Defense Medical Standardization (64616) | |
6665NCM116570 | 6665-01-599-7528 | Detector, gas | Special Features: Toxic vapor analyzer TVA-1000B; offers both photoionization detection (pid) and flame ionization detection (fid); dynamic range (pid): 0 to 2000 ppm;dynamic range (fid): 0 to 50, 000 ppm; nominal flowrate: 1000 cc; display: bar graph and 4 digit lcd; alarms: high, low, and short term exposure limit (stel); temperature range: 0 to 50 deg c; dimensions: 13.5 X 10.3 X 3.2 in; includes probe and case; end item: 6665-01-590-9456 END Item Identification: 6665-01-590-9456 Part Name Assigned BY Controlling Agency: Anlyzer vapor | Defense Medical Standardization (64616) | |
6665NCM116619 | 6665-01-599-7251 | Detector, Radiac | Special Features: Alpha, beta, gamma detector; energy dependent; over-responding by A factor of 6 in the 60-100 kev range when normalized to 137 cesium; thin mica window protected by A 79 pct open stainless steel screen that can be removed; dead time: 200 microseconds Part Name Assigned BY Controlling Agency: Meter end window detector Radiation Type AND Function: Alpha rays detects and beta rays detects and gamma rays detects | Defense Medical Standardization (64616) | |
6665NCM116620 | 6665-01-599-7334 | Detector, Radiac | Special Features: Portable beta/gamma detector; used with any ratemeter or scaler that provides 850-1200 volts with input sensitivity of 30 +/- 10 millivolts; detector: 30-45 MG/CM2 stainless steel wall halogen quenched gm; sensitivity: 1200 cpm per mr/hr (137 cesium gamma) with window closed; dead time: approx. 95 microseconds; connector: series C Part Name Assigned BY Controlling Agency: Meter energy compensated Radiation Type AND Function: Beta rays detects and gamma rays detects | Defense Medical Standardization (64616) | |
6665NCM116622 | 6665-01-599-7342 | Meter, Digital Scaler-Ratemeter | Special Features: Digital ratemeter with scaler; auto ranging; panel mounted locking switch with two detector setups; adjustable alarms; wide range hv; overrange and overload protection; 4 digit digital lcd display; backlight; scaler 1-9999 seconds Part Name Assigned BY Controlling Agency: Meter digital ratemeter scaler | Defense Medical Standardization (64616) |