Hazard-Detecting Instruments and Apparatus: 6640NCM040442, 6665NCM010542, 6665NCM010545
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
6640NCM040442 | 6665-01-530-8830 | Water Testing kit, Bacteriologica | Special Features: 25 tests: contains 25 simplates and 25 single test media tubes; 48 hours to results; positive wells fluoresce under uv light; 4-30 degree C, away from light, recommended storage conditions for hpc media Part Name Assigned BY Controlling Agency: Simplate for hpc 25S Component Quantity: 50 | Defense Medical Standardization (64616) | |
6640NCM051662 | 6665-01-537-5033 | Detector, gas | Special Features: Ammonia chip measurement system, detects ammonia from 0.20 to 5.0 ppm END Item Identification: For use with cms analyzer, part 802-05200 Part Name Assigned BY Controlling Agency: Ammonia cms chip ammonia measures 0.20 to 5.0 ppm | Defense Medical Standardization (64616) | |
6640NCM051664 | 6665-01-537-5034 | Detector, gas | Special Features: Ethylene oxide chip measurement system, detects ethylene oxide from 0.4 to 5.0 ppm END Item Identification: For use with cms analyzer, part 802-05200 Part Name Assigned BY Controlling Agency: Cms chip ethylene oxide measures ethylene oxide from 0.4 to 5.0PPM | Defense Medical Standardization (64616) | |
6640NCM051665 | 6665-01-537-5032 | Detector, gas | Special Features: Formaldehyde chip measurement system, detects formaldehyde from 0.2 to 5.0 ppm END Item Identification: For use with cms analyzer, part 802-05200 Part Name Assigned BY Controlling Agency: Detector gas formaldehyde measuring gas 0.2 to 5.0PPM | Defense Medical Standardization (64616) | |
6640NCM060437 | 6665-01-541-2821 | Spectrometer, Isotope Identifying | Special Features: With 1.4"X2" nal, 3HE and gm detectors; 2.75LBS; temp range: -20 to 55 deg c; water proof, dust tight; protection class: ip 54; drop test: 2'8" on concrete; 9.8" X 3.7" X 3"; functions: nuclide identification, spectrum analysis, dose rate calculation, total dose display, source finding Part Name Assigned BY Controlling Agency: Spectrometer isotope identifinder-ngh+ W/1.4"X2" nal, 3HE & gm detectors | Defense Medical Standardization (64616) | |
6640NCM060438 | 6665-01-541-2405 | Sampler System, Particulate | Special Features: Includes sample pump, charger (100-240V), dps impactor, filter cassettes (2), calibration adapter, rain cap, disposable impaction substrates (25), filter cassette opener, tubing with quick-disconnect, and mounting bracket in heavy-duty lockable carry case Part Name Assigned BY Controlling Agency: Sampler particulate deployable | Defense Medical Standardization (64616) | |
6640NCM060440 | 6665-01-541-2286 | Sampling Pump, Air | Special Features: Handheld pocket pump for low flow; includes one each: pocket pump with nimh battery pack, single charger, type A sample tube holder in soft-side nylon carry case Part Name Assigned BY Controlling Agency: Kit pump air single pocket skc 115V Overall Length: 4.500 inches nominal | Defense Medical Standardization (64616) | |
6640NCM093537 | 6665-01-574-9839 | Indicator, Radiac | Special Features: Surface contamination meter with alpha/beta discrimination; scaler/timer with preset count, preset time for sample measurements; continuous ratemeter mode; alpha, beta, and alpha + beta modes; gross or net counting; approx. 1000 H operation time using 2 C batteries, rechargeable nimh batteries can be used; backlit lcd display; audible indication: single pulse for alpha, chirper mode for beta, proportional to count rate; earphone output; approx. wt: 2 lb; window thickness: 0.87 mg per cubic cm aluminized plastic film; sensitive area: 2.71 X 5.71 in Part Name Assigned BY Controlling Agency: Radeye AB100 contamination monitor Current Type: DC | Defense Medical Standardization (64616) | |
6640NCM104377 | 6665-01-585-2354 | Radiacmeter | Special Features: Rugged air ionization chamber; performs beta-gamma dose rate measurements over A five-decade span ranging from background to 500 msv/hr (50 R/hr); chamber volume: 13.4 cu in; window: 7 MG/CM2 aluminized mylar; window area: 6.2 IN2; beta shield: retractable 1000 MG/CM2 phenolic slide; side wall: 1000 MG/CM2 aluminum and acrylic; six-position switch selects off, X10K, X1K, X100, X10, and X1; each range has front-panel mounted calibration control; also includes audio output, reset, and zero adjust capabilities; also has eans to zero the electrometer leakage current; approx. wt: 3.6 lbs Part Name Assigned BY Controlling Agency: Ion chamber model 9-3 ludlum Radiation Type AND Function: Beta rays measures | Defense Medical Standardization (64616) | |
6640NCM139061 | 6665-01-618-3565 | Tritium Column | Special Features: Tritium columns for liquid scintillator counter, lsc, water sample preparation; designed to replace distillation for most routine tritium analyses of aqueous samples; removes potential interferences in the lsc spectrum, just as distillation does; not intended to be an enrichment procedure; should only be used in situations when required detection limit can be achieved by direct counting of A 5-10 ml aliquot of sample, plus cocktail, processed through column; component: diphonix resin, target: cations, capacity: 0.8 meq; component: anion exchange resin, target: anions, capacity: 0.8 meq, component: polymethacrylate resin, target: organic molecules, capacity: 50 mg; package of 200 Part Name Assigned BY Controlling Agency: Tritium column 75-150U 2ML 200S | Defense Medical Standardization (64616) | |
6640NCM990259 | 6665-01-501-3141 | Detector, gas | Special Features: Glass vials filled with A chemical reagent that reacts to N-hexane; dectes N-hexane in the range of 100 to 3000 parts per million; A calibrated 100 ml sample of air is drawn through the tube with the bellows pump; if the chemical is present the reagent in the tube changes color and the length or the color change typically indicates the measured concentration Part Name Assigned BY Controlling Agency: Detector gas chemical N-hexane 100/A 10S Supplementary Features: Dector gas chemical N-hexane, 100/A, 10'S | Defense Medical Standardization (64616) | |
6650NCM030233 | 6665-01-509-6438 | Sampler, Air, Radiological | Special Features: Constant flow air sampler; 3 wire cord, six foot; 10 amp rating; ul and csa approved; individually calibrated air flow indicator; two stage turbine blower with peripheral exhaust; one horse power motor; self cooling universal type motor; requires 115V, 50-60 hz, 8 amp; weight: 10.5 lbs; dimensions: 8 X 10 X 7 in.; uses 4 N HD-2061 filter, 30 cfm Part Name Assigned BY Controlling Agency: Constant flow air sampler 8X10X7 30 cfm ea | Defense Medical Standardization (64616) | |
666 | 6665-00-161-8120 | Radiacmeter | Special Features: Weight 0.85 kg; portable survey meter consisting of A pressurized ionization chamber, microprocessor-bassed with combined illuminated analog/digital lcd; utilizes an infrared communicator for calibration and allows the instrument to be used as A remote detector; includes programmable flash alarm which causes the display to pulsate at A rate of once per second when measured dose exceeds A preset limit; ionization chamber filled to A pressure of 6 atmospheres; can be used to freeze the max. exposure rate encountered; 5 operating ranges, 0 to 500 micro R/H, 0 to 5 mr/H, 0 to 50 mr/H, 0 to 500 mr/H and 0 to 5 R/hour Radiation Type AND Function: Beta rays detects Radiation Type AND Function: Beta rays measures | Heico Ohmite LLC (63060) | |
6665009992785 | 6665-00-999-2785 | Detector pad, Free Water | General Characteristics Item Description: 47 mm dia, blotting paper disc coated on one side W/uranine, white, smooth, 500 per package | Astrodyne Inc. (26425) | |
6665NCM000201 | 6665-01-521-0469 | Detector kit, gas | Special Features: Kit includes accuro hand pump to find the identity and concentration of hazardous gases, (17) boxes of dectector tubes for use with A sampling matrix for unknown hazardous gases, easy-to-use matrix chart, 3M extension hose, tool kit and spare parts; case is 15 1/2 in by 12 1/4 in by 7 1/2 in Part Name Assigned BY Controlling Agency: Detector kit hazardous materials with detector tubes (1) kit per package | Defense Medical Standardization (64616) | |
6665NCM010177 | 6665-01-495-9611 | Pump, Air Sampling | Special Features: Fas sampling pump, precisely collects A sample volume for A detector tube; full stroke (100ML) and half stroke (50ML) positions are marked exactly by the red line on the pump shaft, handle precisely locks at these positions;calibrated based upon A prescribed (standard) volume of sample;detects and quantifies A large number of gases and gaseous compounds, non-sparking design, attached flow finish indicator tells you when stroke is complete; weighs 230G Part Name Assigned BY Controlling Agency: Pump air sampling precisely collects sample volume F/detector tu | Defense Medical Standardization (64616) | |
6665NCM010483 | 6665-01-497-4649 | Charger, Radiac Detector | Special Features: WEIGHT2 pounds; power 110V to 220V; 50 hz or 60 hz; heavy duty charging mechanism has A positive stop for dosimeter protection; oversized charging knob for easy prercise rezeroing control; compact, light weight and rugged design; bright reading light END Item Identification: For use with the radiacmeter; nsn 6665-01-134-9714 Part Name Assigned BY Controlling Agency: Charger radiac detector alternating current 110/220V ac 50/60HZ | Defense Medical Standardization (64616) | |
6665NCM010541 | 6665-01-514-5645 | Dosimeter Badge, Personal | Special Features: Small, reliable dosimeter which is designed for easy handling, cleanliness, resistance to mechanical impact; can also measure radiation in skin doses; id codes are large and can be punched; the lock mechanism prevents accidental contamination of detection part; used for X-ray radiation detection; A hanger with clip is included for wearing of badge Part Name Assigned BY Controlling Agency: Dosimeter badge for panasonic reader 100S | Defense Medical Standardization (64616) | |
6665NCM010542 | 6665-01-514-4472 | Ud Reader System | Special Features: Computerized automatic tld reader and changer; is organic to the flare utc; the reader is used to read and report the external radiological results obtained by the 802AT dosimeter and also to reset the dosimeter to re-issue to the personnel in the field; built-in glow curve interface; universal INPUT(100-250 vac; 50/60HZ), switching power supply; SIZE:1000MM wide by 910MM high by 545MM deep; weight: 90KG Part Name Assigned BY Controlling Agency: Tld reader and changer for radiological tests | Defense Medical Standardization (64616) | |
6665NCM010545 | 6665-01-516-1977 | Reader, Irda, Electronic Personal | Part Name Assigned BY Controlling Agency: Reader irda epd MK2 (1) per package Special Features: Irda reader for epd MK2 and epdn neutron detector and epdh heat stress monitor series; includes easy epd software | Defense Medical Standardization (64616) |