Hazard-Detecting Instruments and Apparatus: 6640NCM040442, 6665NCM010542, 6665NCM010545

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
6640NCM040442 6665-01-530-8830Water Testing kit, BacteriologicaSpecial Features: 25 tests: contains 25 simplates and 25 single test media tubes; 48 hours to results; positive wells fluoresce under uv light; 4-30 degree C, away from light, recommended storage conditions for hpc media
Part Name Assigned BY Controlling Agency: Simplate for hpc 25S
Component Quantity: 50
Defense Medical Standardization (64616)

Quote

6640NCM051662 6665-01-537-5033Detector, gasSpecial Features: Ammonia chip measurement system, detects ammonia from 0.20 to 5.0 ppm
END Item Identification: For use with cms analyzer, part 802-05200
Part Name Assigned BY Controlling Agency: Ammonia cms chip ammonia measures 0.20 to 5.0 ppm
Defense Medical Standardization (64616)

Quote

6640NCM051664 6665-01-537-5034Detector, gasSpecial Features: Ethylene oxide chip measurement system, detects ethylene oxide from 0.4 to 5.0 ppm
END Item Identification: For use with cms analyzer, part 802-05200
Part Name Assigned BY Controlling Agency: Cms chip ethylene oxide measures ethylene oxide from 0.4 to 5.0PPM
Defense Medical Standardization (64616)

Quote

6640NCM051665 6665-01-537-5032Detector, gasSpecial Features: Formaldehyde chip measurement system, detects formaldehyde from 0.2 to 5.0 ppm
END Item Identification: For use with cms analyzer, part 802-05200
Part Name Assigned BY Controlling Agency: Detector gas formaldehyde measuring gas 0.2 to 5.0PPM
Defense Medical Standardization (64616)

Quote

6640NCM060437 6665-01-541-2821Spectrometer, Isotope IdentifyingSpecial Features: With 1.4"X2" nal, 3HE and gm detectors; 2.75LBS; temp range: -20 to 55 deg c; water proof, dust tight; protection class: ip 54; drop test: 2'8" on concrete; 9.8" X 3.7" X 3"; functions: nuclide identification, spectrum analysis, dose rate calculation, total dose display, source finding
Part Name Assigned BY Controlling Agency: Spectrometer isotope identifinder-ngh+ W/1.4"X2" nal, 3HE & gm detectors
Defense Medical Standardization (64616)

Quote

6640NCM060438 6665-01-541-2405Sampler System, ParticulateSpecial Features: Includes sample pump, charger (100-240V), dps impactor, filter cassettes (2), calibration adapter, rain cap, disposable impaction substrates (25), filter cassette opener, tubing with quick-disconnect, and mounting bracket in heavy-duty lockable carry case
Part Name Assigned BY Controlling Agency: Sampler particulate deployable
Defense Medical Standardization (64616)

Quote

6640NCM060440 6665-01-541-2286Sampling Pump, AirSpecial Features: Handheld pocket pump for low flow; includes one each: pocket pump with nimh battery pack, single charger, type A sample tube holder in soft-side nylon carry case
Part Name Assigned BY Controlling Agency: Kit pump air single pocket skc 115V
Overall Length: 4.500 inches nominal
Defense Medical Standardization (64616)

Quote

6640NCM093537 6665-01-574-9839Indicator, RadiacSpecial Features: Surface contamination meter with alpha/beta discrimination; scaler/timer with preset count, preset time for sample measurements; continuous ratemeter mode; alpha, beta, and alpha + beta modes; gross or net counting; approx. 1000 H operation time using 2 C batteries, rechargeable nimh batteries can be used; backlit lcd display; audible indication: single pulse for alpha, chirper mode for beta, proportional to count rate; earphone output; approx. wt: 2 lb; window thickness: 0.87 mg per cubic cm aluminized plastic film; sensitive area: 2.71 X 5.71 in
Part Name Assigned BY Controlling Agency: Radeye AB100 contamination monitor
Current Type: DC
Defense Medical Standardization (64616)

Quote

6640NCM104377 6665-01-585-2354RadiacmeterSpecial Features: Rugged air ionization chamber; performs beta-gamma dose rate measurements over A five-decade span ranging from background to 500 msv/hr (50 R/hr); chamber volume: 13.4 cu in; window: 7 MG/CM2 aluminized mylar; window area: 6.2 IN2; beta shield: retractable 1000 MG/CM2 phenolic slide; side wall: 1000 MG/CM2 aluminum and acrylic; six-position switch selects off, X10K, X1K, X100, X10, and X1; each range has front-panel mounted calibration control; also includes audio output, reset, and zero adjust capabilities; also has eans to zero the electrometer leakage current; approx. wt: 3.6 lbs
Part Name Assigned BY Controlling Agency: Ion chamber model 9-3 ludlum
Radiation Type AND Function: Beta rays measures
Defense Medical Standardization (64616)

Quote

6640NCM139061 6665-01-618-3565Tritium ColumnSpecial Features: Tritium columns for liquid scintillator counter, lsc, water sample preparation; designed to replace distillation for most routine tritium analyses of aqueous samples; removes potential interferences in the lsc spectrum, just as distillation does; not intended to be an enrichment procedure; should only be used in situations when required detection limit can be achieved by direct counting of A 5-10 ml aliquot of sample, plus cocktail, processed through column; component: diphonix resin, target: cations, capacity: 0.8 meq; component: anion exchange resin, target: anions, capacity: 0.8 meq, component: polymethacrylate resin, target: organic molecules, capacity: 50 mg; package of 200
Part Name Assigned BY Controlling Agency: Tritium column 75-150U 2ML 200S
Defense Medical Standardization (64616)

Quote

6640NCM990259 6665-01-501-3141Detector, gasSpecial Features: Glass vials filled with A chemical reagent that reacts to N-hexane; dectes N-hexane in the range of 100 to 3000 parts per million; A calibrated 100 ml sample of air is drawn through the tube with the bellows pump; if the chemical is present the reagent in the tube changes color and the length or the color change typically indicates the measured concentration
Part Name Assigned BY Controlling Agency: Detector gas chemical N-hexane 100/A 10S
Supplementary Features: Dector gas chemical N-hexane, 100/A, 10'S
Defense Medical Standardization (64616)

Quote

6650NCM030233 6665-01-509-6438Sampler, Air, RadiologicalSpecial Features: Constant flow air sampler; 3 wire cord, six foot; 10 amp rating; ul and csa approved; individually calibrated air flow indicator; two stage turbine blower with peripheral exhaust; one horse power motor; self cooling universal type motor; requires 115V, 50-60 hz, 8 amp; weight: 10.5 lbs; dimensions: 8 X 10 X 7 in.; uses 4 N HD-2061 filter, 30 cfm
Part Name Assigned BY Controlling Agency: Constant flow air sampler 8X10X7 30 cfm ea
Defense Medical Standardization (64616)

Quote

666 6665-00-161-8120RadiacmeterSpecial Features: Weight 0.85 kg; portable survey meter consisting of A pressurized ionization chamber, microprocessor-bassed with combined illuminated analog/digital lcd; utilizes an infrared communicator for calibration and allows the instrument to be used as A remote detector; includes programmable flash alarm which causes the display to pulsate at A rate of once per second when measured dose exceeds A preset limit; ionization chamber filled to A pressure of 6 atmospheres; can be used to freeze the max. exposure rate encountered; 5 operating ranges, 0 to 500 micro R/H, 0 to 5 mr/H, 0 to 50 mr/H, 0 to 500 mr/H and 0 to 5 R/hour
Radiation Type AND Function: Beta rays detects
Radiation Type AND Function: Beta rays measures
Heico Ohmite LLC (63060)

Quote

6665009992785 6665-00-999-2785Detector pad, Free WaterGeneral Characteristics Item Description: 47 mm dia, blotting paper disc coated on one side W/uranine, white, smooth, 500 per package
Astrodyne Inc. (26425)

Quote

6665NCM000201 6665-01-521-0469Detector kit, gasSpecial Features: Kit includes accuro hand pump to find the identity and concentration of hazardous gases, (17) boxes of dectector tubes for use with A sampling matrix for unknown hazardous gases, easy-to-use matrix chart, 3M extension hose, tool kit and spare parts; case is 15 1/2 in by 12 1/4 in by 7 1/2 in
Part Name Assigned BY Controlling Agency: Detector kit hazardous materials with detector tubes (1) kit per package
Defense Medical Standardization (64616)

Quote

6665NCM010177 6665-01-495-9611Pump, Air SamplingSpecial Features: Fas sampling pump, precisely collects A sample volume for A detector tube; full stroke (100ML) and half stroke (50ML) positions are marked exactly by the red line on the pump shaft, handle precisely locks at these positions;calibrated based upon A prescribed (standard) volume of sample;detects and quantifies A large number of gases and gaseous compounds, non-sparking design, attached flow finish indicator tells you when stroke is complete; weighs 230G
Part Name Assigned BY Controlling Agency: Pump air sampling precisely collects sample volume F/detector tu
Defense Medical Standardization (64616)

Quote

6665NCM010483 6665-01-497-4649Charger, Radiac DetectorSpecial Features: WEIGHT2 pounds; power 110V to 220V; 50 hz or 60 hz; heavy duty charging mechanism has A positive stop for dosimeter protection; oversized charging knob for easy prercise rezeroing control; compact, light weight and rugged design; bright reading light
END Item Identification: For use with the radiacmeter; nsn 6665-01-134-9714
Part Name Assigned BY Controlling Agency: Charger radiac detector alternating current 110/220V ac 50/60HZ
Defense Medical Standardization (64616)

Quote

6665NCM010541 6665-01-514-5645Dosimeter Badge, PersonalSpecial Features: Small, reliable dosimeter which is designed for easy handling, cleanliness, resistance to mechanical impact; can also measure radiation in skin doses; id codes are large and can be punched; the lock mechanism prevents accidental contamination of detection part; used for X-ray radiation detection; A hanger with clip is included for wearing of badge
Part Name Assigned BY Controlling Agency: Dosimeter badge for panasonic reader 100S
Defense Medical Standardization (64616)

Quote

6665NCM010542 6665-01-514-4472Ud Reader SystemSpecial Features: Computerized automatic tld reader and changer; is organic to the flare utc; the reader is used to read and report the external radiological results obtained by the 802AT dosimeter and also to reset the dosimeter to re-issue to the personnel in the field; built-in glow curve interface; universal INPUT(100-250 vac; 50/60HZ), switching power supply; SIZE:1000MM wide by 910MM high by 545MM deep; weight: 90KG
Part Name Assigned BY Controlling Agency: Tld reader and changer for radiological tests
Defense Medical Standardization (64616)

Quote

6665NCM010545 6665-01-516-1977Reader, Irda, Electronic PersonalPart Name Assigned BY Controlling Agency: Reader irda epd MK2 (1) per package
Special Features: Irda reader for epd MK2 and epdn neutron detector and epdh heat stress monitor series; includes easy epd software
Defense Medical Standardization (64616)