Hazard-Detecting Instruments and Apparatus: 48-2872, 487338, 48822
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
48-2872 482872 | 6665-01-555-6469 | Radiacmeter | Overall Length: 8.500 inches nominal Detecting Element Type: Scintillation Overall Width: 3.500 inches nominal | Ludlum Measurements Inc. (23609) | |
48310643-01 4831064301 | 6665-01-435-7632 | Detector kit, Carbon Monoxide, Col | Special Features: Combustion test KIT;INCLUDES:1 ea filter material, P/N 47292321;1 ea carrying case, P/N 47292324;1 ea co analyzer, P/N 48218022;1 ea co analyzer sample hose, P/N 48218022-01;REFILL fluid co analyzer, P/N 48218022-03;1 ea smoke test pump, P/N 48218023, P/N 48218023;1 ea filter paper, P/N 48218023-01;1 ea manometer, P/N 48218024;1 ea manometer refill fluid, P/N 48218024-01. Component Quantity: 9 Component Document Origin: Industrial | VPI Acquisition Company LLC (3F033) | |
48-3633 483633 | 6665-01-585-2354 | Radiacmeter | Special Features: Rugged air ionization chamber; performs beta-gamma dose rate measurements over A five-decade span ranging from background to 500 msv/hr (50 R/hr); chamber volume: 13.4 cu in; window: 7 MG/CM2 aluminized mylar; window area: 6.2 IN2; beta shield: retractable 1000 MG/CM2 phenolic slide; side wall: 1000 MG/CM2 aluminum and acrylic; six-position switch selects off, X10K, X1K, X100, X10, and X1; each range has front-panel mounted calibration control; also includes audio output, reset, and zero adjust capabilities; also has eans to zero the electrometer leakage current; approx. wt: 3.6 lbs Part Name Assigned BY Controlling Agency: Ion chamber model 9-3 ludlum Radiation Type AND Function: Beta rays measures | Atlantic Nuclear Corporation (0FHH5) Ludlum Measurements Inc. (23609) | |
48-3739 483739 | 6665-01-615-5715 | Radiacmeter | Radiation Type AND Function: Beta rays detects Overall Length: 21.6 inches nominal Detecting Element Type: Any acceptable | Ludlum Measurements Inc. (23609) | |
483740 | 6665-01-328-2219 | Detector, gas | Mine Safety Appliances Company (1CS58) | ||
483785 | 6665-01-429-2376 | Probe, Sampling, gas Indicator | Special Features: Potentiostat sensor, 0 to 50 ppm hydrogen sulfide. END Item Identification: Sealift conversion ships class Media Detected: Combustible gas | Mine Safety Appliances Company (1CS58) | |
48519 | 6665-01-538-5300 | Probe, Radiac | END Item Identification: Portable radiac equipment | Canberra Dover Inc. (06442) | |
485212 | 6665-01-373-9386 | Tube kit, Hazard Detection | END Item Identification: Mine safety hazmat response detector tube kit General Characteristics Item Description: Hazmat response detector tube kit, includes 12 types of samplair detector tubes, multiple tube holder, aspirator bulb and interpretation guide;tube holder A consists of 4 tubes P/n's 83099, 465519, 460754 and 463838 for positive testing of oxidizing gases, carbon monoxide, aromatic hydrocarbons and organic gases;tube holder B consists of 4 tubes P/n's 454206, 82802, 466612 and 93262 for positive testing of mercaptans or thiols, unsaturated hydrocarbons, acidic gases and hydrogen cyanide;tube holder C consists of 4 tubes P/n's 9245, 85034, 95097 and 85976 for positive testing of basic gases, halgenated hydrocarbons, alcohols and some ethers and carbon dioxide | Mine Safety Appliances Company (1CS58,55799) | |
485233 | 6665-01-373-9385 | Holder, Multiple Tubes | END Item Identification: Nsn 6665-01-373-9386 mine safety hazmat response detector tube kit General Characteristics Item Description: Extra multiple tube holder for use with P/N 485212 hazardous detection tube kit | Mine Safety Appliances Company (1CS58,55799) | |
485960 | 6665-01-013-0486 | Alarm, gas, Automatic | Special Features: Ocarbon monoxide alarm; solid state type; calibrated range 0 to 500 ppm;preset to signal at 50 ppm; power requirements 60 hz, single phase, 115 vac;dimensions: length 15.625 inches, 12.000 width, height 6.750 inches | Mine Safety Appliances Company (55799) | |
486124 | 6665-01-433-3799 | Alarm, gas, Automatic | Mine Safety Appliances Company (1CS58) | ||
486253 | 6665-01-264-2246 | Alarm, gas, Automatic | END Item Identification: Alarm gas automatic 6665-01-225-3233 Indicator Type: Horn and red light Media Detected: Oxygen and combustible gas and hydrogen sulfide | Mine Safety Appliances Company (1CS58,55799) | |
486934 | 6665-01-326-0435 | Probe, Sampling, gas Indicator | Overall Length: 20.000 inches nominal Usage Design: Aircraft | Mine Safety Appliances Company (1CS58) | |
487090077 | 6665-01-597-5272 | Test kit, Garment | Trelleborg Viking Inc. (0KKE3) | ||
487334 | 6665-01-429-8590 | Detector Tube | Part Name Assigned BY Controlling Agency: Detector tube CO-10 glass break-off tip filled W/treated chem General Characteristics Item Description: Mdetector tube CO-10; glass; has break-off tip; filled with treated chemical granules for sampling/measuring carbon monoxide; measuring range 10-3000 ppm; unit qty 10; for use in air force ta number: 907A and 911A | Mine Safety Appliances Company (55799) | |
487338 | 6665-01-457-5732 | Detector, gas | Special Features: Gas detector tubes; sulfor dioxide (SO2) detection; measures concentration of 5-120 ppm gas or vapor; unit issue pg of 10 Part Name Assigned BY Controlling Agency: Detector gas sulfor dioxide (S02) 5-120 ppm gas or vapor 10S | Safeco Inc. (022S1,1UUW4) | |
487339 | 6665-01-362-9913 | Detector, gas | Special Features: Hermetically sealed glass tube; filled W/inert carrier matl which has been impregnated W/A reagent designed to produce A colorimetric indication; measures hydrogen sulfide (H25); range of measurement: 1-200 ppm; number of pump strokes: 1 ps for 10-200 ppm, 10 ps for 1-20 ppm; use for direct reading of the quality of air around power plans, sewage and industrial waste systems; unit pkg qty 10 END Item Identification: Msa thumbpump sampling pump, P/N 485675 Overall Length: 6.000 inches nominal | Mine Safety Appliances Company (55799) | |
487343 | 6665-00-406-9447 | Tube, Halogenated Hy | Federal Resources Supply Company (1Q3Z9) Mine Safety Appliances Company (55799) | ||
487500 | 6665-01-429-8592 | Sampling Pump | Part Name Assigned BY Controlling Agency: Sampling pump W/end of stroke indicator remote sampling adapter Special Features: With end-of-stroke indicator; remote sampling adapter; carrying pouch; pump provides user ability to obtain a precise 100ML sample volume to allow detection of gases and vapors; for use in air force to number: 907A and 911A General Characteristics Item Description: With end-of-stroke indicator; remote sampling adapter; carrying pouch; pump provides user ability to obtain a precise 100ML sample volume to allow detection of gases and vapors; for use in air force to number: 907A and 911A | Mine Safety Appliances Company (55799) | |
48822 | 6665-01-552-6341 | Radiac set | Special Features: Operating power requires: 4 each 1.5V aaa batteries, 150 hours minimum life. Radiation Type AND Function: Gamma rays measures Radiation Type AND Function: Neutron rays measures | Canberra Dover Inc. (06442) |