Hazard-Detecting Instruments and Apparatus: 394RDU, 40001200-30, 40001220-30

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
394RDU 6665-01-368-3289Detector, RadiacOverhoff Technology Corporation (57774)

Quote

396218-001
396218001
6665-01-568-2451Window kitEND Item Identification: Mobile vacis 4300 sba 4X2
Science Applications International (1HKQ6)

Quote

39701 6665-00-136-7971Calibration kit, gas Indicators aPart Name Assigned BY Controlling Agency: Field calibration unit
Functional Description: Checks the accuracy of combustible gas indicators
Rosemount Analytical Inc. (30646)

Quote

3998 6665-01-443-1951Detector, gasDetcon Inc. (0XL44)

Quote

399-800000-000
399800000000
6665-01-443-1951Detector, gasDetcon Inc. (0XL44)

Quote

3998B 6665-01-443-1951Detector, gasDetcon Inc. (0XL44)

Quote

3L 6665-01-204-8173Detector, gas, Ammonia, 10SSpecial Features: Measuring gas range: 0.5-78PPM
Part Name Assigned BY Controlling Agency: Detector gas ammonia measuring gas range 0.5-78PPM 10S
Instrument Depot Inc. (0NWP4)

Quote

40 6665-00-803-6592Indicator, Combustible gas, PortabSpecial Features: Adual scale insturment; one scale 0 to 100 percent lel; other 0 to 10 percent lel; calibrated on pentane; complete calibration curves, conversion chart and special 5 ft humidity stabilizing line
Part Name Assigned BY Controlling Agency: Combustible gas indicator
Scale Range: +0.1/+10.0 percent of lower limit of explosibility single indicator 2ND scale
Mine Safety Appliances Company (55799)

Quote

40 6665-01-191-7226Detector, gas, Mercury, 10SSpecial Features: Measuring gas range: 0.5-13.2 MG/M3
Part Name Assigned BY Controlling Agency: Detector gas mercury measure .05-13.2 MG/M3 10S
Instrument Depot Inc. (0NWP4)

Quote

40 6665-01-279-7174RadiacmeterRadiation Type AND Function: Beta rays measures
Radiation Type AND Function: Gamma rays measures
Detecting Element Type: Solid state
Ludlum Measurements Inc. (23609)

Quote

40-000
40000
6665-01-023-0983Sampler, ParticulateGeneral Characteristics Item Description: Seperates particles into 5 descending calibrations: 5.5 microns at 0 pct respirability, 5.5 to 3.5 microns at 20 pct respirability, 3.5 to 2.0 microns at 50 pct, 2.0 to 0.3 microns at 100 pct and A 25 mm membrane for particles smaller than 0.3 microns, plates are aluminum, 1.4 litres per min. air flow, battery pack and vacuum pump
Andersen Samplers Inc. (58036)

Quote

40000013 6665-01-181-3172Filament, Combustible gas IndicatSpecial Features: Each end of wire connected to A brass terminal which is mounted in A fiber filament base; each filament accurately balanced and interchangeable; suitable for use as comparison or analyzing filaments; for use with protable gas combustible indicator, 6665-00-542-1442
Part Name Assigned BY Controlling Agency: Filament combustibl gas indi PLATINUM.688IN O/A LG.002IN O/A dia
Overall Length: 0.688 inches nominal
Avox Systems Inc. (53655)
Vallen Safety Supply Co. (07674)

Quote

40000030 6665-00-429-6025Filament, Combustible gas IndicatSpecial Features: Exterior container weight: 18 pounds; exterior container cubic measure: 3 cubic feet; exterior container quantity: 48; intermediate package quantity: 1; unit of issue cube: 0.035 cubic feet; unit of issue weight: 0.44 pounds; dual range; DIA:0.0008MM; lg: 28.6MM;REPLACEMENT filament for indicator, 6665-00-542-1442;UNIT package quantity: 2
Overall Length: 1.125 inches nominal
Overall Diameter: 0.0003 inches nominal
Avox Systems Inc. (53655)

Quote

4-00000-35
40000035
6665-00-278-1816Cylinder, gas, DisposableEND Item Identification: 66652356264
General Characteristics Item Description: Contains methane gas, 2 1/2 pct in air, 250 psi, non-flammable
Avox Systems Inc. (53655)

Quote

40000059 6665-00-099-9204Calibration Check kit, gas MonitoSpecial Features: Calibration kit for vapotester, models M1, M5, M6, and gas tester, part no. 11-550 used in detection of combustible gases or vapors. kit con- sists of gas cylinder test bag, cylin-der insert, clamp, barbed insert, carrying bag and instruction sheet
Avox Systems Inc. (53655)

Quote

40000103 6665-00-542-1442Indicator, Combustible gas, PortabSpecial Features: Dual range; in case; W/hose, 4720-00-429-6030; W/O battries and probe; for probe, order 6665-01-498-9369; requires six batteries; for battery, order 6135-01-499-0621; for detection of combustible gas or vapors in the toxic or combustible range, including gasoline vapor
Part Name Assigned BY Controlling Agency: Indicator combustible gas ptbl dual range in casr W/samplng hose
ERR Default: Err default
Avox Systems Inc. (53655)

Quote

40001200-30
4000120030
6665-01-561-5267Elevator AssemblyBattelle Memorial Institute (79986)

Quote

40001200-50
4000120050
6665-01-561-5267Elevator AssemblyBattelle Memorial Institute (79986)

Quote

40001203-10
4000120310
6665-01-587-7729Carrier, End PlateBattelle Memorial Institute (79986)

Quote

40001203-30
4000120330
6665-01-587-7729Carrier, End PlateBattelle Memorial Institute (79986)

Quote

40001204-01
4000120401
6665-01-588-2085Idler AssemblyBattelle Memorial Institute (79986)

Quote

40001220-30
4000122030
6665-01-557-2452Carrier Assembly, IdBattelle Memorial Institute (79986)

Quote

  • We solve sourcing challenges for 394RDU, 399-800000-000, 40, 40-000, 40000059, 40001200-30, 40001200-50, 40001203-30, 40001204-01, 40001220-30 - NSN parts, hard to find, long lead time and obsolete components.