Hazard-Detecting Instruments and Apparatus: 136-42-1357, 1375-500, 1410-00

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
136-42-1357
136421357
6665-01-302-6743Modification kit, Tester, Leakage,General Characteristics Item Description: C/O coupling quick disconnect, 5-19-1900-1;VALVE solenoid, normal open, D136-30-184-1;VALVE solenoid, normal closed, 136-42-184-2;TUBING polyethylene 88P;CONNECTOR, brass, B-600-1-8;CONNECTOR B810-11-8;PIPE hanger assy, C136-30-30-12;NAMEPLATE, C136-42-842-7;COVER ASSY;136-42-769;USED with the M14 leakage tester
Edgewood Chemical Biological Center (81361)

Quote

136-42-1507
136421507
6665-01-145-2438Hood, TestingEdgewood Chemical Biological Center (81361)

Quote

136-42-1554
136421554
6665-01-252-4276Hood, TestingGeneral Characteristics Item Description: C/O hood, top pn 136-42-1552; hood half, right pn 136-42-1551-2; hood half, left pn 136-42-1551-1; patch, reinforcement pn 136-42-1553
Edgewood Chemical Biological Center (81361)

Quote

136-45-420
13645420
6665-01-082-1111Tester, Air Leakage, Impermeable sGeneral Characteristics Item Description: C/O test pressure dial, pressure control dial, suit dial air flow
Edgewood Chemical Biological Center (81361)

Quote

1366920U 6665-01-553-1645Installation kit, Chemical AgentOshkosh Corporation (45152)

Quote

13677346 6665-01-600-0682Case, Commander's MonitorPart Name Assigned BY Controlling Agency: Commander's monitor case
Overall Width: 15.00 inches nominal
Overall Height: 6.50 inches nominal
U S Army Aviation and Missile (18876)

Quote

137 6665-01-299-4270Detector, gasSpecial Features: Chloroform; tlv-twa (acgih) 10PPM; measurable concentration 4-400PPM
Detecting Element Type: Chemical reaction
Detecting Element Detachability: Detachable
Instrument Depot Inc. (0NWP4)
Sensidyne LP (63882)

Quote

1370420-02D
137042002D
6665-01-541-9758Led IndicatorsEND Item Identification: Sterilizer, vacuum steam
SIE Computing Solutions Inc. (51398)

Quote

137-130
137130
6665-00-741-8908AmplifierWorldwide Development Corp. (33726)

Quote

137-133
137133
6665-00-741-8942Amplifier, TemperatuWorldwide Development Corp. (33726)

Quote

137-136
137136
6665-00-742-7500Board, Power SupplyWorldwide Development Corp. (33726)

Quote

1375-500
1375500
6665-01-572-8812Reconnaissance System, Nuclear-BiEdgewood Chemical Biological Center (81361)

Quote

137M 6665-01-299-4270Detector, gasSpecial Features: Chloroform; tlv-twa (acgih) 10PPM; measurable concentration 4-400PPM
Detecting Element Type: Chemical reaction
Detecting Element Detachability: Detachable
Sensidyne LP (63882)

Quote

138 6665-01-206-5960Detector, gas, Methyl Chloride, 10SSpecial Features: Measuring gas range: 25-1500 ppm
Part Name Assigned BY Controlling Agency: Detector gas methyl chloride gas range 25-1500 ppm 10S
Instrument Depot Inc. (0NWP4)

Quote

13879 6665-01-555-0682Nozzle ExtensionPart Name Assigned BY Controlling Agency: Nozzle extension
General Characteristics Item Description: Nha: 6665-01-552-2704
Overall Length: 2.165 inches nominal
Smiths Detection-Edgewood Inc. (23667)

Quote

1400-2002
14002002
6665-01-179-6424Probe, gas SamplingEND Item Identification: Jerome instrument corporation analyzer model 411
General Characteristics Item Description: Aluminum tubing W/clear anodized surface treatment; 0.250 in. od; 0.125 in. id; 12 in. lg
Arizona Instrument Corp. (59830)
Arizona Instrument LLC (1DS44)

Quote

14063 6665-01-362-9913Detector, gasSpecial Features: Hermetically sealed glass tube; filled W/inert carrier matl which has been impregnated W/A reagent designed to produce A colorimetric indication; measures hydrogen sulfide (H25); range of measurement: 1-200 ppm; number of pump strokes: 1 ps for 10-200 ppm, 10 ps for 1-20 ppm; use for direct reading of the quality of air around power plans, sewage and industrial waste systems; unit pkg qty 10
END Item Identification: Msa thumbpump sampling pump, P/N 485675
Overall Length: 6.000 inches nominal
Mine Safety Appliances Company (55799)

Quote

140B 6665-01-394-1262Detector, gasSpecial Features: High frequency linear response electron capture detector;detector can be remotely mounted (5 ft) from controls;output is an analog signal suitable for driving A chart recorder or standard digital counter with 0/10 volts;detector temperature range control +160 to 320 deg C.;contains stainless steel detector block, heater block, platinuim resistor temperature sensor, over-temp limit SWITCH;1/8 in O.D. stainless steel tube 6 in lg.;detection volume 180 milliliters;gas flow 60/100 milliliters per minute of 95 pct ARGON/5 pct methane or nitrogen or SF6;2 position switch to optimize pulse width for carrier GAS;16 position recorder OUTPUT;10 turn baseline adjustment;power requirement 115 vac 60HZ 100 watts;electrical connectors for anode, cathode, frequency output, recorder output, temperature control, and input power cord
END Item Identification: Model 1095 leak detector, P/N 1095D100, mfg 19459
Overall Length: 8.250 inches nominal
Valco Instruments Company Inc. (55637)

Quote

141 6665-01-480-4428Detector, gasSpecial Features: 0.1 - 1.5 % V range
END Item Identification: For detection of vinyl chloride
Part Name Assigned BY Controlling Agency: Detector gas chemical reaction glass 0.1-1.5 % V range 10S
Instrument Depot Inc. (0NWP4)

Quote

1410-00
141000
6665-01-426-0208Detector, gasSpecial Features: Sulfur dioxide gas detector system; includes: 1 ea.control unit model 1410-04, 4EA.MODEL 1401-10 detector head. operating TEMP.M40.0 to P120.0 degrees F.
Detecting Element Type: Chemical reaction
Case Material: Steel, corrosion resisting
Sierra Monitor Corporation (66647)

Quote

  • We solve sourcing challenges for 136-42-1357, 136-42-1507, 1366920U, 1370420-02D, 137-130, 137-136, 1400-2002, 140B, 141, 1410-00 - NSN parts, hard to find, long lead time and obsolete components.