Hazard-Detecting Instruments and Apparatus: 109U, 110-174-003, 11-1175

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
109U 6665-01-512-3018Tube, gas DetectorSpecial Features: Chlorine gas detector glass tube; 1-2 strokes; 0.05-2.0PPM measuring range; 1PPM stel ceiling
Part Name Assigned BY Controlling Agency: Gas detector tube chlorine 10S
Sensidyne LP (63882)

Quote

10-CAL
10CAL
6665-01-225-4152Alarm, gas, AutomaticErdco Engineering Corporation (01579)

Quote

10-CALW
10CALW
6665-01-225-4153Alarm, gas, AutomaticErdco Engineering Corporation (01579)

Quote

10X5-1800
10X51800
6665-01-515-7778Detecting Element, RadiacSpecial Features: Rate resolution 0.01 mr/hr; max 65 R/hr; dose resolution 0.1 ur; max 230 r; rate specifications 0.1 MR/HR-65 R/hr; 0.1 UGY/HR-575 mgy/hr; exposure specs 1 NR-230 r; 0.01 NGY-2 gy; calibration accuracy porm 4 pct using X-rays at 150 kvp and 10.2 mm ai hvl; exposure rate dependence P 0 pct, M 5 pct, 0.1 mr/hr to 20 R/hr, M10 pct to 65 R/hr; energy dependence porm 5 pct, 33 kev to 1.33 mev, with build up material; construction polycarbonate walls and electrode; conducting graphite exterior coating; 1800 CM3 active volume; 0.54 kg
Functional Description: Intended for low-level radiation measurements such as shielding leakage, irradiator and environmental
Radcal Corporation AN M D H Company (4P061)

Quote

110-00013-03
1100001303
6665-01-593-4286Detector kit, Chemical AgentAhura Scientific Inc. (392A9)

Quote

110-100-0140-U30
1101000140U30
6665-01-483-4101Perm Device AmmoniaSpecial Features: Capsules sontaining pure chemical compound, ammonia
Benfield Marketing LTD (EA488)

Quote

11-0121
110121
6665-01-157-7115Filtering MaterialBacharach Inc. (05083)

Quote

110-174-0001
1101740001
6665-01-596-1416Detection kit, Bulk Homemade ExplSpecial Features: Box includes 28 individual kits, each kit good for 25 tests
Part Name Assigned BY Controlling Agency: Bulk hme precursor detection kit
General Characteristics Item Description: Detects presence of nitrates, urea, urea nitrate, and chlorates
Naval Surface Warfare Center (14083)

Quote

110-174-0001/2011-01-A1-HME-CS
1101740001201101A1HMECS
6665-01-604-5877Detection kit, BulkSpecial Features: 1 CASE=8 BOXES=28 kt in 1 BX=224 kt in one case
END Item Identification: Detection kit, bulk homemade
Naval Surface Warfare Center (14083)

Quote

110-174-0001 REV. A
1101740001REVA
6665-01-596-1416Detection kit, Bulk Homemade ExplSpecial Features: Box includes 28 individual kits, each kit good for 25 tests
Part Name Assigned BY Controlling Agency: Bulk hme precursor detection kit
General Characteristics Item Description: Detects presence of nitrates, urea, urea nitrate, and chlorates
Naval Surface Warfare Center (14083)

Quote

110-174-002
110174002
6665-01-603-8525Detection kit RefilNaval Surface Warfare Center (14083)

Quote

110-174-003
110174003
6665-01-603-8423Vial, RelpacementNaval Surface Warfare Center (14083)

Quote

1101B-648AN
1101B648AN
6665-01-024-7762Asher, Plasma AnalysisGeneral Characteristics Item Description: 6 chamber, 40 to 300 deg C range, line voltage 208 to 240 volts ac, 60 hz, 20 amperes, 1000 watts
Branson Intl Plasma Corp. (51505)

Quote

1107310-1
11073101
6665-01-006-6129Tube, SamplingOceanetics Inc. (33867)

Quote

1107310-2
11073102
6665-01-006-6130Tube, SamplingOceanetics Inc. (33867)

Quote

1107N 6665-00-542-6615Test kit, Boiler Water, PhosphateGeneral Characteristics Item Description: Cconsists of carrying case, slides, base, stannous chloride power, molybdate reagent, dispenser cap, test tube brush, filter paper, plastic funnel, 12 oz. spring scale, 17 oz. spring scale and A midget lamp
Taylor Technologies Inc. (89975)

Quote

111 6665-01-205-2345Detector, gas, Methyl Alcohol, 10SSpecial Features: Measuring gas range: 0.002-4.5%
Part Name Assigned BY Controlling Agency: Detector gas methyl measuring gas range .002-4.5% 10S
Instrument Depot Inc. (0NWP4)

Quote

11109 6665-01-573-1738Indicator, RadiacSpecial Features: Capable of detecting and identifying gamma and neutron sources; docking station; carrying case; performs three functions: survey (locate radioactive source), measure dose (determine exposure hazard level), and analyze (identify nuclides for risk assessment); back-lit display shows real-time count, count rate, and dose rate in numeric and graphic format; energy range: 20 kev to 3.0 mev; data storage: 40000 dose samples, 185 spectrum samples; operating temperature: 14 to 122 deg f; battery life (continuous operation): 8 hrs (rechargeable), 12 hrs (alkaline)
Part Name Assigned BY Controlling Agency: Exploranium GR-135 plus identifier radioactive isotope identification device
Width: 4.000 inches nominal
Defense Logistics Agency (89875)

Quote

11-11-000
1111000
6665-01-013-9899Sensor, MonitorEND Item Identification: Monitor gas combustible, general monitors inc model no. 1200
General Monitors Inc. (17952)

Quote

11-1175
111175
6665-00-278-1816Cylinder, gas, DisposableEND Item Identification: 66652356264
General Characteristics Item Description: Contains methane gas, 2 1/2 pct in air, 250 psi, non-flammable
Avox Systems Inc. (53655)

Quote

  • We solve sourcing challenges for 109U, 10X5-1800, 110-00013-03, 110-174-0001/2011-01-A1-HME-CS, 110-174-002, 110-174-003, 1107310-1, 111, 11-11-000, 11-1175 - NSN parts, hard to find, long lead time and obsolete components.