FSC 6665 Hazard-Detecting Instruments and Apparatus: 6665-01-042-7860, 6665-01-051-4708, 6665-01-053-1754

Get a Quote

 
NSNMFG SKUItem NameDetailsManufacturer (CAGE)RFQ
6665-01-042-7860
6665010427860
460-0017-WWAnalyzer System, WaterGeneral Characteristics Item Description: Sampler 4, 171-A017-03, proportional pump-single speed, 1 colormeter-single channel, 1 analytical cartridge, 116DO98-01 cyanide, 2 filters nanometers, 1DISTILLATION apparatus, recorder-single pen, 1 phenol cartridge, 2 filter 505NM, 1 sulfate, cartridge, 1 SET-2 filters 460NM
Bayer Corp. (59426)

Quote

6665-01-042-9401
6665010429401
SM-D-688695
IM-185()/UD
10511013
RadiacmeterGeneral Dynamics Land Systems (56161)
Joint Electronics Type Designation (80058)
US Army Communications (80063)

Quote

6665-01-043-2191
6665010432191
DT-236()/PD
CSTAL-73-11
Detector, RadiacRadiation Type AND Function: Gamma rays measures
Radiation Type AND Function: Neutron rays measures
Radiation Type AND Function: X-rays measures
Joint Electronics Type Designation (80058)
US Army Communications (80063)
US Army Electronics Research And (20309)

Quote

6665-01-044-3836
6665010443836
C5085357
CP-696/UD
Computer-Indicator, RadiacPower Source: External
Current Rating IN Amps: 0.5
Direct Current Voltage Rating IN Volts: 24.0
Joint Electronics Type Designation (80058)
US Army Combat Surveillance And (57946)
Sechan Electronics, Inc. (7Z941)

Quote

6665-01-044-4640
6665010444640
CS-40Meter, Roentgen RateCase Material: Aluminum
Scale Range: +0.0/+0.2 roentgens
Scale Range: +0.0/+2.0 roentgens
Canberra Industries Inc. (06442)

Quote

6665-01-045-7079
6665010457079
492DDetector, RadiacRadiation Type AND Function: Gamma rays measures
Detecting Element Type: Geiger-mueller tube
Detecting Element Detachability: Detachable
QSA Global Inc. (23244)

Quote

6665-01-046-6084
6665010466084
43997Base AssemblyMeggitt (New Hampshire), Inc. (58880)

Quote

6665-01-046-6332
6665010466332
AN/PDR-452Radiac setJoint Electronics Type Designation (80058)

Quote

6665-01-046-9924
6665010469924
460Data Acquisition SystemEND Item Identification: B-20 program
Canberra Industries Inc. (18165)

Quote

6665-01-048-1810
6665010481810
160Combustible gas Indicator set, PoGeneral Monitors Inc. (17952)

Quote

6665-01-048-3820
6665010483820
75476Filament, Combustible gas IndicatEND Item Identification: M-S-A explosimeter, model 5
Material: Any acceptable
Coil Form Type: Solid
Mine Safety Appliances Company (55799, 1CS58)

Quote

6665-01-048-6364
6665010486364
30-52Smoke DetectorKOP-Coat Inc. (11111)

Quote

6665-01-048-8923
6665010488923
81A
81
Probe, RadiacSpecial Features: Measures linear and circularly polarized signals 1-18 ghz +/- 1.5 db, 0.3-1 ghz -1.0 to -4.0 db; power overload at 25 deg c; 0.5 watts
END Item Identification: Radiation hazard meter
Supplementary Features: Manufacturers name: radiation probe
General Microwave Corporation (11332)

Quote

6665-01-048-9960
6665010489960
50-7020Alarm, gas, AutomaticSpecial Features: Monitoring and alarm system, continuous, combustible and toxic gas
Bacharach, Inc. (05083)

Quote

6665-01-049-8982
6665010498982
D5-67-271Paper, Chemical Agent DetectorSpecial Features: Polyethylene terephthalate material; grayish green color; designed for personnel and vehicle use; adhesive oneside; pressure sensitive type; removeable protective backing; furnished on A 5 cm core roll; with 1 plastic recloseable bag; packaged in A sealed moisture proof bag in A cardboard dispenser
Width: 5.000 centimeters nominal
Length: 4.600 meters nominal
Edgewood Chemical Biological Center (81361)

Quote

6665-01-050-1364
6665010501364
3464-4
3675020-002
003464-004
Alarm, gas, AutomaticDynalec Corporation (12763)
Wing Corp. (97536)

Quote

6665-01-050-6325
6665010506325
LAC 2Computer-Indicator, RadiacSpecial Features: Incorporates A quartz window; has A reproducibility of plus or minus 5 pct, efficiency of 0.85 counts/alpha, background less than 0.1 cpm, to be made with activated zinc sulfide/silver coating; 0.125 in. quartz window, SIZE5 in. high, 2 in. dia., volumn 95 ml
Power Source: Self-contained
Intelligence Input Method: Air or electrical
Becton, Dickinson and Company (22790)

Quote

6665-01-051-4708
6665010514708
194504Meter, Roentgen RateSpecial Features: Range 0 to 50 parts per million, drift +/- .5 percent, per 12 or 24 hours, -32 deg to 120 deg F., live zero recorder recommended
Rosemount Analytical Inc. (88177)

Quote

6665-01-052-9660
6665010529660
300-10764AMeter, RoentgenSpecial Features: Markings shall not contain any radioactive materials
Phaostron Instrument and Electronic (77221)

Quote

6665-01-053-1754
6665010531754
EGas FumiscopeHassler Robert K Co. (14684)

Quote