Electrical and Electronic Properties Measuring and Testing Instruments: TO-HJ-302V/B, TO-HJ-3-834, TP20
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
TO-HJ-302V/B TOHJ302VB | 6625-01-183-9366 | Divider, Power, Radio Frequency | Special Features: Freq range 2 to 250 mhz; isolation 30 db; insertion loss 0.5 db; vswr 1.3 to 1; input power 3 watts; impedance 50 ohms; operating temp minus 54 degrees C to 100 degrees c; useful life 100, 000 hours; altitude 70, 000 ft max; five pin terminals; case matl nickel 400; header matl steel 1010; header and pins gold plated per MIL-G-45204; O/a lg 0.780 in.; O/a dia 0.363 in. End Item Identification: AN/ALQ-158(V) Precious Material and Location: Header and terminal surfaces gold | Crane Co. (0N8W8) Signal Technology Corp. (32252) | |
TOHJ303V | 6625-01-048-2913 | Divider, Power, Radio Frequency | Special Features: 10-200 frequency range mhz, 3 outputs, 3 watts max power, 30 db max isolation | Crane Co. (0N8W8) Signal Technology Corp. (32252) | |
TO-HJ-3-2051 TOHJ32051 | 6625-01-201-6759 | Divider, Power, Radio Frequency | Special Features: Input rf power 1 watt; insertion loss 0.5 db max; operating frquency range 10 to 100 mhz; 4 ports; weight 0.060 lb max; 5 pin type terminals; plug in mounting; 0.53 in. max lg; 0.40 max dia | Crane Co. (0N8W8) Signal Technology Corp. (32252) | |
TO-HJ-3-834 TOHJ3834 | 6625-01-226-4233 | Divider, Power, Radio Frequency | Special Features: Material: case: nickel 400, header: cold rolled steel 1010, gold plated per MIL-G-45204 or nickel plate, pins: kovar, gold plated per MIL-G-45204 or nickel plate Overall Length: 0.770 inches nominal Frequency Rating: 50.0 megahertz minimum and 400.0 megahertz maximum | Crane Co. (0N8W8) Signal Technology Corp. (32252) | |
TO-HJ-402 TOHJ402 | 6625-00-150-0047 | Divider, Power, Radio Frequency | Special Features: Two way in phase power divider/combiner; 0.875 in. lg; 0.375 in. dia; five leads 0.017 in. dia; one key tab located on 0.375 in. dia; one mechanical ground; one internal isolating resistor; frequency response two mhz min toone hundred mhz max; no. of outputs two; isolation db min forty; insertion loss db max 0.250; phase one deg; amplitude db 0.100; impedance nom fifty ohms; vswr max 1.2:1; power max three watts; temp range neg 54 degree 0 to pos 100 degree C | Crane Co. (0N8W8) Signal Technology Corp. (32252) | |
TO-J4-32 TOJ432 | 6625-01-036-2472 | Divider, Power, Radio Frequency | Special Features: Quadrature hybrid; isolation 25 db min; impedance 50 ohms; temp. range: -54 to 100 deg celcius Overall Length: 0.780 inches nominal Frequency Rating: 32.0 megahertz nominal | Crane Co. (0N8W8) Signal Technology Corp. (32252) | |
TONEOHM700 | 6625-01-172-6833 | Test set, Electronic Systems | Special Features: Isolates shorts, opens & other problems on P.C.boards;main modes of measurement are milliohm meter W/range 2 mohms to 20 kohms, a microvoltmeter W/range 1 millivolt to 210 volts, a current tracer probe capable of detecting current paths up to 700 ohms;ea mode has adjustable audio tone | Exor Inc. (63029) | |
TOOL-201 TOOL201 | 6625-01-362-5573 | Calibrator, Electrical Power | Barber-Colman Co. (65149) | ||
TOOL-203 TOOL203 | 6625-01-156-4264 | Resistor, Test Assem | Barber-Colman Co. (65149) | ||
TOOL-204 TOOL204 | 6625-01-156-4263 | Resistor, Test Assem | Barber-Colman Co. (65149) | ||
TOSHIBA 420CDS TOSHIBA420CDS | 6625-01-440-4974 | Programmer, Microcircuit | Special Features: Utilize program maintenance for the calibration of the electronics on the high frequency, X-ray apparatus , model clinix VP4, nsn 6525-01-384-9296. End Item Identification: 6525-01-384-9296 Part Name Assigned BY Controlling Agency: Programmer microcircuit used on nsn 6525-01-384-9296 | Marconi Medical Systems Inc. (9R532) Philips Medical Systems Cleveland (4F797) | |
TOTAL PAK 8 TOTALPAK8 | 6625-01-250-8673 | Programmer, Microcircuit | Functional Description: Programs programmable logic arrays (pla) and proms | Data I/O Corporation (54193) | |
TOTAL TEST TOTALTEST | 6625-01-386-8728 | Probe, Test | Carrier Consumer Products Div. Of (55962) | ||
TP10-2 TP102 | 6625-01-253-5310 | Plug-in unit, Electrical-Electron | Special Features: Imput impedance 10 megohms; dc accuracy 0.1 pct; overvoltage protection up to 1000 vdc or peak ac; meter power rqmts 90.0 to 132.0 vac nominal Overall Width: 19.000 inches nominal Overall Height: 12.000 inches nominal | Williams International Co. LLC (24235) | |
TP-104-01-00 TP1040100 | 6625-01-381-8177 | Test Probe Attachment | Overall Length: 0.350 inches minimum and 0.370 inches maximum Overall Diameter: 0.125 inches nominal FSC Application Data: Test set, electronic equipment | AVX Tantalum Corporation (17554) Components Corp. (26364) | |
TP-105-01-03 TP1050103 | 6625-01-501-2403 | Probe, Test | Special Features: Material - phosphor bronze, electro tin finish or brass wire, tin plated; collar material - glass filled pbt or glass filled nylon; mtg. - 0.035 to .0.042 dia. hole; color - orange End Item Identification: Nuclear power plants | Components Corp. (26364) | |
TP-106-01-03 TP1060103 | 6625-01-484-8983 | Probe, Test | Criticality Code Justification: ZZZY Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specifications | Components Corp. (26364) | |
TP165X | 6625-01-527-7901 | Probe, Test | End Item Identification: 1650 series of multifunction installation testers Special Features: Only available for purchase in europe | Fluke Corporation (89536) Fluke France (FA1X8) | |
TP-2 TP2 | 6625-01-254-9478 | Test Prod kit | General Characteristics Item Description: 6SUPPORT for 7106 accu-test; kit consists of 12.000 in power cord extension W clips; neutral ground reversal probe; isolated ground probe; 36.000 in mini extension cord; neutral impedance adaptor; remote ground impedance probe; deluxe carring case | Ecos Electronics Corp. (56273) | |
TP20 | 6625-01-418-0132 | Probe, Test | Special Features: Finger guard protection;length oftip 0.750 inches;probe tip diameter 0.080 inches;maximum voltage 1000B;MAXIMUM current 10A;FLEXIBLE test leads TIP Termination Type: Probe | Fluke Corporation (89536) Radiospares SAS (FA0Q5) |