MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
PD03WRLEEC149 | 6625-01-507-3879 | Ohmmeter | Circuit Current for Which Designed: DC Measurement Range: +0.0/+2000.0 milliohms single indicator single range Features Provided: Portable | Warner Robins Air Logistics Center (98752) | |
PD03WRLEEC151 | 6625-01-511-1235 | Test set, Navigation | Frequency Rating: 400.0 hertz nominal Phase: Single AC Voltage Rating: 115.0 volts nominal | Warner Robins Air Logistics Center (98752) | |
PD03WRLEEC154 | 6625-01-514-3942 | Analyzer, Spectrum | Special Features: Pd name optical spectrum analyzer; measurement level linear and logarithmic scale of 0.1, 0.2, 0.5, 1, 5, & 10 db/division; this is capable of peakholding mode and external synchronization pulsed light measurements; also random access memory with capacity of 501 samples and 15 screen shots Meter Scale Range: This instrument measures signals with a 10 pm resolution and a 20 pm wavelength accuracy in the 1.55 pico meter band; measurement range of 600 to 1700 nm | Warner Robins Air Logistics Center (98752) | |
PD03WRLEEC155 | 6625-01-507-0834 | Generator, Signal | Special Features: Internal and external modulation enabled to allow combined amplitude and frequency or phase modulation; pulse modulation with other external pulse source; allows for am, fm, pulse, and/or phase modulation; internal modulation source for waveforms: sinusoidal, square, and triangular Frequency Rating: 50.0 hertz minimum and 440.0 hertz maximum Phase: Single | ||
PD03WRLEEC157 | 6625-01-506-6212 | Generator, Signal | Special Features: External am, fm, pulse modulation Frequency Range Rating: +0.000/+20.000 gigahertz | ||
PD03WRLEEC166 | 6625-01-516-1424 | Reflectometer, Metallic Time Doma | Power Source: External and self-contained Part Name Assigned BY Controlling Agency: Time domain reflectometer for metallic conductors Voltage in Volts and Current Type: 12.0 dc and 230.0 ac | Warner Robins Air Logistics Center (98752) | |
PD03WRLEEC167 | 6625-01-535-2732 | Calibrator, Oscilloscope | Overall Depth: 17.500 inches nominal Overall Height: 5.500 inches nominal Overall Width: 17.000 inches nominal | Warner Robins Air Logistics Center (98752) | |
PD03WRLEEC169 | 6625-01-544-0409 | Frequency Standard | Special Features: Frequency outputs of 1MHZ, 5MHZ, and 10MHZ +11 dbm (2.5VPP) into 50 ohms, mean time between failure 4000 hrs status leds of operate, stabilized, unlocked, and fault, eight channel C/a code with reciver tracking of eight satellites End Item Identification: Auto test equipment/auto test systems Furnished Items and Quantity: Antenna, 50FT antenna cable RG6, connectors (5) 50 ohm bnc, operation and maintenance MANUALS(2) | ||
PD03WRLEEC174 | 6625-01-518-7402 | Generator, Pulse | Special Features: Item is a programmable pulsed power source for iff and tacan aircraft test equipment calibration; frequency range for the tacan shall be 960 to 1215 mhz, for the iff they shall be 1024 to 1036 and 1084 to 1096 mhz;equipment shall be rack mount compatible; item not to exceed 90 pounds in total weitht Installation Design: RACK Circuit Construction Type: Solid state | ||
PD03WRLEEC177 | 6625-01-517-5483 | Analyzer, Spectrum | Special Features: Pd name: class 3 2.9GHZ spectrum analyzer with interal tracking generator Frequency Range Rating: +0.000/+2.900 gigahertz | Warner Robins Air Logistics Center (98752) | |
PD03WRLEEC180 | 6625-01-407-6262 | Test set, Radio Frequency Power | Special Features: Operating power of 103.5 to 126, 207 to 253VAC or power sources of 100/110/115/120/210/220/230/240VAC at line freq of 48 to 66HZ, 360 to 440HZ Inclosure Feature: Single item W/housing Measurement Unit: Average power | Warner Robins Air Logistics Center (98752) | |
PD04-18004000 PD0418004000 | 6625-01-557-1909 | Divider, Power, Radio Frequency | Special Features: Operating temperature 0.0 deg C to plus 70.0 deg c; multioctave bands; low loss and low vswr; excellent amplitude balance; excellent phase balance Overall Length: 1.990 inches nominal Overall Width: 0.360 inches nominal | Miteq Inc. (33592) | |
PD04WRLEEC03 | 6625-01-520-5111 | Calibrator, Multimeter | Special Features: Unit shall meet all accuracy requirements when operating temperature isbetween 0 degrees celsius and 50 degrees celsius. warm up time shall not exceed 30 minutes. dc voltage better THAN0 to 1100 volts, output voltage within+ or - 5 degrees celsius of the calibration temperature. shall be capable ofaccuracy specifications at any calibration temperature between 15 and 35 degrees celsius. ac voltage, .22MV to 1100V, accuracy .0022 to 1100 volts, frequency range 40 - 300 khz. weight shallnot exceed 75 pounds, 7"H X 22.75"D(SHALL not exceed) shall fit in a standard 19" rack. power consumption, less than 300 watts Functional Description: High accuracy dc, ac and resistance calibration system, that may include a monolithic integrated unti or seperate amplifier as necessary | Warner Robins Air Logistics Center (98752) | |
PD04WRLEEC06 | 6625-01-266-5934 | Generator, Pulse | Circuit Construction Type: Solid state Frequency per Channel: 0.000005 megahertz minimum operating channel and 50.000000 megahertz maximum operating channel Output Wave Shape: Pulse, gate | ||
PD04WRLEEC08 | 6625-01-527-7697 | Voltage Standard | Special Features: Frequency range: 10HZ to 30MHZ Frequency Rating: 47.5 hertz minimum and 63.0 hertz maximum Phase: Single | Warner Robins Air Logistics Center (98752) | |
PD04WRLEEC09 | 6625-01-518-8991 | Resistor, Decade | Special Features: Will provide highli accurate resistance values from 10 milliohms to 1.2 megohms with a minumum resolution of 20 microohms Part Name Assigned BY Controlling Agency: Pd name: decade resistance standard Overall Electrical Value Range: +0.000/+1.200 megohms | Warner Robins Air Logistics Center (98752) | |
PD04WRLEEC10 | 6625-01-083-1726 | Generator, Function, Electronic Te | Special Features: These dimension may very, this is a generic item Overall Length: 14.720 inches nominal Overall Width: 10.020 inches nominal | ||
PD04WRLEEC16 | 6625-01-512-4024 | Analyzer, Digital Data, Electronic | Special Features: Capable of being rack-mounted in a standard 19-INCH equipment rack with an optional rack-mount conversion kit; pd name: arinc 429 data bus analyzer Indicator Type: Cathode ray tube Phase: Single | Warner Robins Air Logistics Center (98752) | |
PD04WRLEEC17 | 6625-01-527-7214 | Calibrator, Frequency | Special Features: Shall not exceed 75 lbs; power consumption shall be less than 300 watts; shall be furnished with accessories necessary for mounting in a standard 19 inch eia rack; the unit shall meet all the accuracy requirements specified when the operating temperature is maintained to within 0 degrees to 50 degrees celsius; meter display shall be visible in low light conditions Overall Height: 7.000 inches nominal Overall Depth: 22.750 inches nominal | Warner Robins Air Logistics Center (98752) | |
PD04WRLEEC18 | 6625-01-521-8463 | Resistance Standard | Special Features: Power 120 vac +/- 10%, 60HZ +/- 3%; weight 300 lbs.; rack is required for this system; operating temp. 22.8DEGREES C, +/- 3.3 degrees c; complete set of interface cables included; 200 feet of shielded soild copper wire suitable for making standard 4 wire, low noise, low thermal, resistance measurements; process controller shall be a minimum of 200MHZ intel pentium, 32MB memory, 1GB hard drive and 17" monitor;compliance voltage +/- 30 volts; total measurement/uncertainity, resistance range 0.1 to 100M, uncertainity <1 to <25, test current range 10MICROAMP to 150 milli-amp continuously variable Overall Length: 72.000 inches nominal Overall Width: 36.000 inches nominal | Warner Robins Air Logistics Center (98752) |