Electrical and Electronic Properties Measuring and Testing Instruments: N5182B, N5241A, N5532A-OPT504
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
N5182B | 6625-01-622-8528 | Generator, Signal | Special Features: Frequency 10 mhz; amplitude >+4 dbm, nominal into 50 () load; input frequency, standard 10 mhz; option 1ER 1 to 50 mhz; lock range + 1 ppm; amplitude -3 dbm to + 20 dbm, nominal impedance 50 (), nominal; waveform sine or square | Agilent Technologies Australia P/L (Z9N17) Agilent Technologies Inc. (1LQK8) | |
N5182B-503OPT/1EM/1EL/UNT/UNV/U- N5182B503OPT1EM1ELUNTUNVU | 6625-01-647-7013 | Generator, Signal | Part Name Assigned BY Controlling Agency: Mxg X-series signal generator Extra Long Reference Number: N5182B-503OPT/1EM/1EL/UNT/UNV/UNW/UNY/UNZ/303/IEQ/099/656/N5182BU-431 Reference Number Differentiating Characteristics: Extra long part number | Agilent Technologies Inc. (1LQK8) | |
N5182B-503 OPT 303/656/UNT/UNV- N5182B503OPT303656UNTUNV | 6625-01-642-8235 | Generator, Signal | Overall Length: 19.2 inches nominal Overall Height: 3.5 inches nominal Overall Width: 16.8 inches nominal | Agilent Technologies Inc. (1LQK8) | |
N5183B-BND01 N5183BBND01 | 6625-01-651-0643 | Signal Generator Subassembly | End Item Identification: AN/USQ-149(V)2, tls & se III Part Name Assigned BY Controlling Agency: Microwave siggen | Technical Communities Inc. (1RPN6) | |
N5193A-540-SS2-AT1-EP1-UNT-WC1- N5193A540SS2AT1EP1UNTWC1 | 6625-01-652-2950 | Generator, Signal | Agilent Technologies Inc. (52708) | ||
N5222A | 6625-01-641-9949 | Generator Group, Signal | Agilent Technologies Inc. (1MY97) | ||
N5222A-010-219-1CP N5222A0102191CP | 6625-01-630-5133 | Analyzer, Network | Overall Depth: 22.700 inches nominal Overall Height: 11.000 inches nominal Overall Width: 19.000 inches nominal | Agilent Technologies Inc. (1LQK8) | |
N5222A OPT 020-080-219-UK6 N5222AOPT020080219UK6 | 6625-01-649-3994 | Analyzer, Network | III Part Name Assigned BY Controlling Agency: Network analyzer | Agilent Technologies Inc. (1LQK8) | |
N5224A-217-008-010-025-080-090 N5224A217008010025080090 | 6625-01-652-8521 | Analyzer, Spectrum | Agilent Technologies Inc. (52708) Keysight Technologies Australia (Z0ST5) | ||
N5225A-210 N5225A210 | 6625-01-644-5015 | Analyzer, Network | III Part Name Assigned BY Controlling Agency: Microwave network analyzer Special Features: 10 mgz to 50 ghz, 2 port, single source, base CONFIGURATI0N opt. 210 | Agilent Technologies Inc. (1LQK8) | |
N5225A-E01-VNA N5225AE01VNA | 6625-01-620-6461 | Nrp, Network Analyze | Agilent Technologies Inc. (1LQK8) | ||
N5230A PNA-L N5230APNAL | 6625-01-646-7890 | Analyzer, Network | III End Item Identification: Omnibus age list III Part Name Assigned BY Controlling Agency: Network analyzer | Agilent Technologies Inc. (1LQK8) | |
N5230C | 6625-01-633-4279 | Analyzer, Network | III Part Name Assigned BY Controlling Agency: Analyzer, microwave network Special Features: Numerous types, phases, polarity, cycles, bandwidth, in | Agilent Technologies Inc. (60259) | |
N5241A | 6625-01-623-4808 | Analyzer, Network | Part Name Assigned BY Controlling Agency: Pna-X network analyzer Special Features: 10MHZ to 13.5GHZ | Agilent Technologies Australia P/L (Z9N17) Agilent Technologies Inc. (1LQK8) | |
N5242A-010,200,080 N5242A010200080 | 6625-01-656-6773 | Analyzer, Network | Agilent Technologies Inc. (1LQK8) | ||
N5242A-200-219 N5242A200219 | 6625-01-620-4708 | Analyzer, Network | Frequency Rating: 10.0 megahertz minimum and 26.5 gigahertz maximum 1ST operating power rqmt Part Name Assigned BY Controlling Agency: Pna-X network analyzer | Agilent Technologies Inc. (1LQK8) | |
N5532-20007 N553220007 | 6625-01-631-4379 | Coupler, Digital Data | Part Name Assigned BY Controlling Agency: Connector input | Agilent Technologies Inc. (1LQK8) | |
N5532-20010 N553220010 | 6625-01-631-4471 | Divider, Power, Radio Frequency | III Part Name Assigned BY Controlling Agency: Spliter output | Agilent Technologies Inc. (1LQK8) | |
N5532-20018 N553220018 | 6625-01-631-4310 | Divider, Power, Radio Frequency | III Part Name Assigned BY Controlling Agency: Splitter output | Agilent Technologies Inc. (1LQK8) | |
N5532A-OPT504 N5532AOPT504 | 6625-01-563-7084 | Sensor, Current | End Item Identification: 4940-01-551-2884;MAINTENANCE facility, transportable Part Name Assigned BY Controlling Agency: Sensor, current | Agilent Technologies Inc. (1LQK8) |