Electrical and Electronic Properties Measuring and Testing Instruments: FO01788-B-A-1C, FOS 850/1300, FPCDB115
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
FO01788-B-A-1C FO01788BA1C | 6625-01-541-1078 | Test Probe, Fiber Op | End Item Identification: Fighter aircraft - first ( F18 E/F ) | Glenair Inc. (06324) | |
FOCABKIT-08 FOCABKIT08 | 6625-01-561-1613 | Fib Optic cable kit | End Item Identification: Gpete; otdr (6625-01-3080) and olts (6650-01-510-8502) General Characteristics Item Description: Consists of 2 cable kits in hard shell case with foam blow mold: mm hqrc kit for use with optical loss test set (olts) photonix model MTS-NV-D110M (6650-01-510-7502) and mm/sm hqlc kit for use with otical time domain reflectometer (htdr) jdsu model MTS-NV-P3 (6650-01-525-3080) Part Name Assigned BY Controlling Agency: Fiber optic multimode-single mode cable kit | Naval Research Laboratory (3NBG8) | |
FOCS-1 FOCS1 | 6625-01-335-9900 | Calibrator, Electrical Power | Special Features: Manufacturers suggested name calibration set, fiber optics;c/O optical-to-electrical plug-in MG0901A;STABILIZED light SOURCES-2 MG921A, MG923A;OPTICAL spectrum analyzer MS9001B/B1;OPTICAL signal generator MG9801A;LASER heads LHIR-0050;HELIUM neon laser 05 LLR805 Overall Width: 426.0 millimeters nominal Overall Height: 266.0 millimeters nominal | Air Force Metrology and Calibration (30653) | |
FORM3SINGLETUBE0-100VDC FORM3SINGLETUBE0100VDC | 6625-00-446-9203 | Multiplier, Electrical Instrument | Yokogawa Corporation of America (60336) | ||
FOS 850/1300 FOS8501300 | 6625-01-560-2423 | Fiber Optic Light | Special Features: Used with fiber optic power meters; infrared led; fixed st; 0.3 radians beam divergence; continuous wave pulse duration; 200 uw maximum output; 9V alkaline battery; low battery indicator; 0-40 C operating temperatures | Fluke Corporation (89536) | |
FOT-22A-WC1-WC FOT22AWC1WC | 6625-01-527-1167 | Meter, Power Factor | Special Features: Power range: plus 10 to minus 60 dbm; number of calibrated wavelengths: 10; weight: 0.9 pounds; temperature: operating, minus 10 degree celsius to 50 degree celsius, storage, minus 40 degree celsius to 70 degree celsius; humidity: 0 percent to 95 percent NON0CONDENSING Overall Length: 7.250 inches nominal Overall Width: 4.000 inches nominal | Exfo America Inc. (0XZT5) | |
FOTZ10883-B FOTZ10883B | 6625-01-394-4110 | Voltmeter | Installation Design: Panel Indicator Type: Dial W/pointer End Item Identification: Cargo truck | Ford Motor Co. (23040,57526) | |
FOTZ-10883-C FOTZ10883C | 6625-01-330-6935 | Meter, Arbitrary Scale | Ford Motor Co. (23040,57526) | ||
FP-02079 FP02079 | 6625-01-544-0273 | Test set, Electronic Altimeter | Special Features: Tests 10 X MA2-30, includes vacuum reservoir. 110V / fast climb rate | Alti-2 Inc. (1NNV4) | |
FP039 | 6625-00-239-8887 | Probe, Magnetic Field, Interferenc | End Item Identification: Model 750 gaussmeter | Dowty RFL Industries Inc. (49673) Magnetic Instrumentation Inc. (66635) | |
FP2000 | 6625-01-467-5895 | Probe, Magnetic Field, Interferenc | Amplifier Research Corp. (14651) | ||
FP2000/KIT FP2000KIT | 6625-01-539-5559 | Probe, Magnetic Field, Interferenc | Special Features: Used in radio freq interference/ electro-magnetic compatibility test system | Amplifier Research Corp. (14651) | |
FP 2083 FP2083 | 6625-01-536-7841 | Probe, Magnetic Field, Interferenc | Special Features: Contains a rechargeable nickel-camium battery; designed for use in radio frequency interference/electromagnetic compatiblity (rfi/emc) test system applications; measures the field strength in ea. of 3 axis; frequency response 80MHZ to 40GHZ; dynamic range is 1 to 300 volts per meter Overall Length: 17.000 inches nominal Frequency Rating: 40.0 gigahertz maximum | Amplifier Research Corp. (14651) | |
FP-5 FP5 | 6625-01-038-2661 | Lead, Test | Material: Copper core conductor all conductors Conductor Form: Stranded all conductors Cross-Sectional Shape Style: Round | B&K Precision Corporation (08098) | |
FP5000 | 6625-01-472-6562 | Probe, Electrical Field, Interfere | Special Features: Frequency 10KHZ-250MHZ, 250MHZ-1GHZ; 4 ranges: 10, 30, 100, 30 Overall Length: 63.5 millimeters nominal Overall Width: 63.5 millimeters nominal | Amplifier Research Corp. (14651) | |
FP 5031 FP5031 | 6625-01-482-8252 | Probe, Magnetic Field, Interferenc | Special Features: Electric field sensor; 1 to 24 samples per second; nicad battery rechargeable through charging jack; replacable batteries Overall Length: 2.800 inches nominal Overall Width: 2.500 inches nominal | Amplifier Research Corp. (14651) | |
FP-6 FP6 | 6625-01-038-2661 | Lead, Test | Material: Copper core conductor all conductors Conductor Form: Stranded all conductors Cross-Sectional Shape Style: Round | B&K Precision Corporation (08098) | |
FP7018/KIT FP7018KIT | 6625-01-560-8879 | Probe, Electrical Field, Interfere | Special Features: Probe kit is a broadband isotropic electrical field measurement tool used for emc and emi applications; 3 mhz to 18 ghz frequency response; 30 samples per second sample rate; 0 - 50 deg C operating temp; 350 grams in wt; powered by 2 aa nimh batteries; 40 hrs operating time; 3 hrs charging time; class 1 laser device Overall Length: 420.0 millimeters nominal Overall Width: 65.0 millimeters nominal | Amplifier Research Corp. (14651) | |
FP7060/KIT FP7060KIT | 6625-01-591-8112 | Probe, Electrical Field, Interfere | Special Features: Includes FP760 probe, 10 meter glass cable, international battery charger and carrying case Part Name Assigned BY Controlling Agency: Electric field probe kit | Amplifier Research Corp. (14651) | |
FPCDB115 | 6625-00-625-8174 | Mixer, Module | General Characteristics Item Description: Double balanced mixer, 10 to 1000 mhz, 50 ohms impedance, 0.375 in. lg, 0.50 in. W, 0.125 in. H, eight 0.017 pins FSC Application Data: Test set, pulse power | Signal Technology Corp. (32252) |