Electrical and Electronic Properties Measuring and Testing Instruments: BCDDS1770, BCM348, BD-10AS

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
BCDDS1770 6625-01-025-6692VoltmeterOverall Length: 1.375 inches maximum
Overall Width: 1.750 inches nominal
Overall Height: 1.750 inches nominal
Jewell Instruments LLC (15309)

Quote

BCG199B/003SEA
BCG199B003SEA
6625-01-560-1673Scopemeter, MedicalSpecial Features: Dual input 100-200 mhz bandwidth; up to 2.5 gs/S real-time sampling per input; 27, 500 points per input record length using scoperecord mode; automatic capture and replay of 100 screens; automatic waveform measurements; four hours rechargeable nimh battery pack; includes a 5, 000 counts true-rms multimeter and a trendpolt paperless recorder;includes software, carrying case and accessories; model 199B/003S; 200MHZ bandwith W/scc kit and cal CER/C190 hard case
Part Name Assigned BY Controlling Agency: Scopemeter medical model 199B/003S 200MHZ bandwidth W/case and accessories
Government Scientific Source Inc. (0S908)

Quote

BCGBC10-9000
BCGBC109000
6625-01-550-3339Tachometer, Digital, Medical EquipPart Name Assigned BY Controlling Agency: Tachometer digital F/medical equipment
Special Features: This item will be used to calibrate medical equipment. dual function medical digital tachometer is a dual function instrument providing contact and non-contact measurement of rotational and linear motions. with an accuracy of 0.25% of indicating reading 1 lsd, the 1726 is ideal for use in production, engineering, inspection, quality control and maintenance; the model 1726 comes complete with a convex tip, concave tip, 10 cm linear measuring wheel and carrying case; the power supply is a neda type 1604, 9 volt transistor battery, and the most significant display character flashes to indicate need for replacement;the compact size and light weight, for easy one-hand operation while the rugged, high impact housing provides for years of dependable service
Government Scientific Source Inc. (0S908)

Quote

BCGBC10-90002
BCGBC1090002
6625-01-550-3339Tachometer, Digital, Medical EquipPart Name Assigned BY Controlling Agency: Tachometer digital F/medical equipment
Special Features: This item will be used to calibrate medical equipment. dual function medical digital tachometer is a dual function instrument providing contact and non-contact measurement of rotational and linear motions. with an accuracy of 0.25% of indicating reading 1 lsd, the 1726 is ideal for use in production, engineering, inspection, quality control and maintenance; the model 1726 comes complete with a convex tip, concave tip, 10 cm linear measuring wheel and carrying case; the power supply is a neda type 1604, 9 volt transistor battery, and the most significant display character flashes to indicate need for replacement;the compact size and light weight, for easy one-hand operation while the rugged, high impact housing provides for years of dependable service
Government Scientific Source Inc. (0S908)

Quote

BCI-111
BCI111
6625-01-364-2512Meter, Ampere-hourPlymouth Industries Inc. (21653)

Quote

BCIT-1553
BCIT1553
6625-01-588-8215Test set, Electronic SystemsSpecial Features: Application
End Item Identification: Misc aircraft support components
Test Type for Which Designed: Provides data bus health monitoring for message quality, loading, and terminal response on a powered avionics system. bus integrity testing provides electrical analysis of cable networks via a high performance time domain reflectometer
Itcn Inc. (0T7T6)

Quote

BCM148 6625-01-429-9541Test set, BatteryMidtronics Inc. (0P2U2)

Quote

BCM248 6625-01-429-9542Test set, BatteryMidtronics Inc. (0P2U2)

Quote

BCM348 6625-01-429-9543Test set, BatteryMidtronics Inc. (0P2U2)

Quote

BCP-200/510
BCP200510
6625-01-546-0580Lead, TestEnd Item Identification: Ah AK-2G antenna kit
Part Name Assigned BY Controlling Agency: Current probe
A H Systems Inc. (54656)

Quote

BCP-200/511
BCP200511
6625-01-546-0581Lead, TestEnd Item Identification: Ah AK-2G antenna kit
Part Name Assigned BY Controlling Agency: Current probe
A H Systems Inc. (54656)

Quote

BCP-510
BCP510
6625-01-537-5312Probe, TestSpecial Features: Wide requency range of 20 hz to 1MHZ;APERTURE 1.2 inches;dia. 3.9 inches;max. current amps 100;TRANSFER impedance db -56 to -30
TIP Termination Type: Clamp around
A H Systems Inc. (54656)

Quote

BCP-511
BCP511
6625-01-546-0588Probe, TestSpecial Features: Capable of measuring pulse currents up to 1000 amperes with a duty cycle of 0.001, connector bnc-type, female
Overall Diameter: 3.900 inches nominal
TIP Termination Type: Clamp around
A H Systems Inc. (54656)

Quote

BCR50B 6625-01-217-6613Indicator, Digital DisplayWidth: 3.920 inches nominal
Length: 4.280 inches nominal
Current Type: AC
Transducer Controls Corporation (52158)

Quote

BCS101A 6625-01-104-0742Simulator, bus ControllerGeneral Characteristics Item Description: Is 20.250 in. lg, 14.500 in. W, 12.500 in. h; weighs 43 lbs; power 105-125 vac, 50-400 hz
SCI Systems Inc. (17981)

Quote

BCSFSN1A-001
BCSFSN1A001
6625-01-244-4118Filter, Light, Cathode Ray TubeGetronics Government Solutions LLC (33322)

Quote

BCX2B1865 6625-00-140-0560VoltmeterSpecial Features: 4 mtg hole/studs 0.112 in. dia
Overall Length: 1.760 inches nominal
Overall Height: 1.750 inches nominal
Wacline Division Of (94916)

Quote

BD019020 6625-00-009-5504Meter, Arbitrary ScaleSpecial Features: Has 4 to 1 magnification dial glass
Overall Length: 2.670 inches nominal
Overall Width: 1.615 inches nominal
Quanta Systems Corp. (08539)

Quote

BD041SAC202 6625-00-620-0556Meter, NullOverall Length: 2.781 inches nominal
Installation Design: Panel
Style Designator: Round flush mtg
Lockheed Martin Corporation (03538)

Quote

BD-10AS
BD10AS
6625-01-277-4055Tester, Generator, High FrequencyGeneral Characteristics Item Description: Consists of 1 probe, 1 attachment wire with plug and 1 on/off switch; used in vacuum leak, corona discharge and lamp ignition applications; input requirement: 120 volts, 50/60 hertz; tester output: 10000 to 50000 volts at frequencies of approx one half megahertz; operating time: intermittent 10 minutes continuous
FSC Application Data: Test set, elect. equip.
Electro-Technic Products Inc. (3N762)

Quote