Combination and Miscellaneous Instruments: H832-7101, HD400-1, HD400-2
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
H832-7101 H8327101 | 6695-01-488-9669 | Control-Power Supply | Special Features: Used in conjunction with fan performance sensor (fps); low speed warning detector (lswd) Operation Method: Automatic Power Supply Type: Any acceptable | Cargill Inc. (96162) | |
H832-7101-603 H8327101603 | 6695-01-488-9669 | Control-Power Supply | Special Features: Used in conjunction with fan performance sensor (fps); low speed warning detector (lswd) Operation Method: Automatic Power Supply Type: Any acceptable | Cargill Inc. (96162) | |
H8406 | 6695-01-441-9880 | Panel, Indicator | Everest VIT UK LTD (K2F14) Welch Allyn Holdings Inc. (64475) | ||
H844-CV912 H844CV912 | 6695-01-295-7886 | Transducer, Motional Pickup | END Item Identification: Apu B-1B aircraft Overall Length: 1.430 inches nominal Overall Width: 1.200 inches nominal | Skurka Aerospace Inc. (95270) | |
H845-CV918 H845CV918 | 6695-01-192-7409 | Transducer, Motional Pickup | END Item Identification: Auxillary power unit, B-1B acft Special Features: First leg 2.13 in. lg, 0.9 in. od; second leg 2.193 in. lg, 0.858 in. min & 0.861 in. max od W/hub 0.68 in. od, 3 sided flange W/ 3 holes 0.218 in. min & 0.226 in. max dia | Skurka Aerospace Inc. (95270) | |
H911-CW573 H911CW573 | 6695-01-388-5360 | Transducer, Motional Pickup | END Item Identification: Pacer dawn Special Features: Hci item; inductance 40 mh max; dc resistance 110 ohms max; temp range minus 100 deg F to 450 deg F Overall Length: 11.698 inches nominal | Skurka Aerospace Inc. (95270) | |
H92 | 6695-01-232-9966 | Meter Movement | Movement Type: Moving coil, permanent magnet Circuit Current FOR Which Designed: DC Movement Suspension Method: Metal pivot base | Phaostron Instrument and Electronic (77221) | |
H975-CY338 H975CY338 | 6695-01-353-4908 | Transducer, Motional Pickup | Skurka Aerospace Inc. (95270) | ||
H976-CY339 H976CY339 | 6695-01-350-1717 | Transducer, Motional Pickup | Skurka Aerospace Inc. (95270) | ||
HAL 100-S HAL100S | 6695-01-481-3213 | Transducer, Motional Pickup | END Item Identification: Cpca apras; command control and communication sys 427M Special Features: Item is A current transducer offers electronic measurement of currents with galvanic isolation between the primary (measured) and the analog output (control) signal; nominal current 1N: 100 A rms; measuring range: + or - 300 a: operating temp: 0 degrees C to + 70 degrees c; storage temp: -25 degrees C to + 85 degrees c; current consumption: 25 ma max: package: potted into an insulated self-extinguishing plastic case UL94VO; fastening by 2 holes 4.5 mm dia and 30.48 mm between centers or to bus bar by 1 hole 4.5 mm dia; connection to primary circuit: through-hole 15 X 20 mm; connection to secondary circuit: on molex connector 5045-04 ag straight pin friction lock header Current Type: Ac/dc | LEM U.S.A. Inc. (0S2B6) | |
HAS 100-S HAS100S | 6695-01-618-9136 | Transducer, Motional Pickup | END Item Identification: Battery charger Overall Length: 40.0 millimeters nominal Overall Width: 30.0 millimeters nominal | LEM U.S.A. Inc. (0S2B6) | |
HB1 | 6695-00-497-3500 | Bag, Handle, Detecto | FRL Incorporated (22522) | ||
HC-1412 HC1412 | 6695-01-565-1434 | Indicator Clogging | Special Features: 50 psi | Tronair Inc. (1RBA3) | |
HC-1849 HC1849 | 6695-01-565-1814 | Indicator Clogging | Special Features: 25 psi | Tronair Inc. (1RBA3) | |
HC-E6746 HCE6746 | 6695-01-242-7397 | Transducer, Motional Pickup | Spang Power Control (08510) | ||
HCS-301 HCS301 | 6695-01-412-4798 | Control, Indicator | Special Features: Aacuracy air flow +/- 2% full scale, temp control +/- 1 deg C and humidity control +/- 3% rh; completely automated system to precisely control the flow, temp and humidity of air; incorporates electronically the 3 sensors and controlling mechanisms; safety features include panel lights on the control module which indicate if proper water pressure, water level and air flow are available Part Name Assigned BY Controlling Agency: Flow-temperature-humidity controlsystem Supplementary Features: Required to produce calibration fas for titan launch critical toxic vapor detectors | Army and Air Force Exchange Service (0MRM9) | |
HCS-401 HCS401 | 6695-01-412-4798 | Control, Indicator | Special Features: Aacuracy air flow +/- 2% full scale, temp control +/- 1 deg C and humidity control +/- 3% rh; completely automated system to precisely control the flow, temp and humidity of air; incorporates electronically the 3 sensors and controlling mechanisms; safety features include panel lights on the control module which indicate if proper water pressure, water level and air flow are available Part Name Assigned BY Controlling Agency: Flow-temperature-humidity controlsystem Supplementary Features: Required to produce calibration fas for titan launch critical toxic vapor detectors | Nelson Miller Research Inc. (0MRM8) | |
HCT-20 HCT20 | 6695-01-007-8996 | Detector, Infrared | General Characteristics Item Description: 1 to 30 micron spectral range, mercury cadmium telluride is preferred detector material, 1 to 50 ma current, 3 to 20 V/cm, operating temp 77 deg K, resistance 30 to 300 ohms, time constant 100 nsec | Infrared Associates Inc. (54486) | |
HD400-1 HD4001 | 6695-00-127-0489 | Dynamometer, Run-in | END Item Identification: P/N EAL1028M5 Test Type FOR Which Designed: Actuator electric Inclosure Feature: Multiple item W/housing | Magtrol Inc. (03692) | |
HD400-2 HD4002 | 6695-01-583-6436 | Dynamometer, Run-in | Special Features: 24 volt, 55 continous watts Height: 6.250 inches nominal Length: 17.000 inches nominal | Magtrol Inc. (03692) |