Chemical Analysis Instruments

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
00-000920-77 115V
0000092077115V
6630-01-109-3285Chromatograph, gasGeneral Characteristics Item Description: Thermal conductivity type detector, 4 filament wire; single column; 115 vac, 50/60 hz, 1 kw; column oven 8 in. W, 7.5 in. H, 6.5 in. D, temp range ambient to 400 deg c; isothermal proportional temperature controller; solid state bridge/power supply, 0-24 vdc output, 0-300 ma; overall dimensions 17 in. W, 15.75 in. H, 16.25 in.
Varian Associates Inc. (20641)

Quote

00-0010
000010
6630-01-476-4792Analyzer, HematologyGeneral Characteristics Item Description: Power 100/240 volt (less than 120 w), 50/60 hz
Special Features: Electronic counting and sizing of cells in triplicate counting with platelet counting and cyanmethemoglobin analysis; capable of performing the following quantitative functions on less than 20 micro liters of whole blood with results in less than 60 seconds; hemoglobin, hematocrit, red blood count inluding red cell indices (mcv, mch, mchc), white blood count with absolute lymphocyte count and per cent lymphocyte of total white blood count, platelet count
Part Name Assigned BY Controlling Agency: Blood cell counter:
Defense Medical Standardization (64616)

Quote

00002 6630-01-283-9315Electrode, SodiumNova Biomedical Corp. (59941)

Quote

00-004100-00
0000410000
6630-01-016-0412Chromatograph, gasGeneral Characteristics Item Description: Liquid chromatograph, 250 ml solvent capacity, 0 to 5000 psi presure range 0 to 200 ml/hr variable flow rate stainless steel and polytetrafluoroethylene constuction, 115/230 vac, 50/60 hz, 250 watt, high pressure injector, 7 gal capacity water bath, 70 deg C max temp, varian aerograph model A-25 recorder included in assembly, 20 chart speeds, 1MV to 1 V selectable span
Communications & Power Industries (99313)

Quote

0000 761 000
0000761000
6630-01-503-1266Analyzer, Clinical ChemistryCurrent Type: AC
Voltage IN Volts: 220.0
Frequency Rating: 50.0 hertz nominal or 60.0 hertz nominal
Instrumentation Laboratory (HE801)

Quote

0000761000 6630-01-503-1266Analyzer, Clinical ChemistryCurrent Type: AC
Voltage IN Volts: 220.0
Frequency Rating: 50.0 hertz nominal or 60.0 hertz nominal
Instrumentation Laboratory Company (22270)

Quote

000082904 6630-01-263-0725Panel, Salinity IndicatorGeneral Characteristics Item Description: Single unit assembly; range of operation 0.50 pm chloride; 21 inches H, 17.5 inches W, 15 inches dp; 60 lbs; alum. housing and electronic assy; used for salt content in water on ship board
Naval Medical Material Support (66736)

Quote

00-011100-00
0001110000
6630-01-074-5629Data System, ChromatographyGeneral Characteristics Item Description: 103.5-126.5 vac, 60 hz, 220 W max; operating temp range 10-40 deg c; 16 cm H, 46 cm W, 56 cm d; power cord, recorder cable, instruction manual, printer ribbon, paper roll; stores 9 method files, 127 events max time programmed in A file
Communications & Power Industries (99313)

Quote

00-011100-00 OPT1560
0001110000OPT1560
6630-01-074-5629Data System, ChromatographyGeneral Characteristics Item Description: 103.5-126.5 vac, 60 hz, 220 W max; operating temp range 10-40 deg c; 16 cm H, 46 cm W, 56 cm d; power cord, recorder cable, instruction manual, printer ribbon, paper roll; stores 9 method files, 127 events max time programmed in A file
Communications & Power Industries (99313)

Quote

00012 6630-01-271-1373Lubricant, Clinical Chemistry AnaGeneral Characteristics Item Description: 1 oz tube for nova 1 thru 6 analyzers
Part Name Assigned BY Controlling Agency: Lubricant clinical chemistry analyzer 1OZ tu nova 1THRU6 analyzr
Nova Biomedical Corp. (59941)

Quote

00018 6630-01-192-9455Conditioning Solution, Sodium EleGeneral Characteristics Item Description: Etches the glass of the electode to sensitize the elements for ion exchange as well as clean the sensing elements of the electrode to ensure accurate readings; used on nova 1, 4, thru 13
Part Name Assigned BY Controlling Agency: Conditioning sol sodium electrode for use W/nova 4 ANALYZER100ML
Nova Biomedical Corp. (59941)

Quote

00019 6630-01-180-3423Wash Solution, ElectrodeSpecial Features: Hazardous ingredient; hypochlorous acid, sodium salt, sodium hypochlorite 0.2 mol/l; soluble; clear colorless to pale yellow liquid; for use W/nova 1 through nova 13 ise analyzers
Part Name Assigned BY Controlling Agency: Cleaning solution electrode 50 ml
Primary Container Type: Bottle
Nova Biomedical Corp. (59941)

Quote

00-0214
000214
6630-01-473-7416Field Service kit, Chemical AnalySpecial Features: Piccolo point-of-care chemistry field service kit includes: 998-5007 diagnostic software; 998-5008 diag.softw.installation pkg; 100-5039 lab software; 998-0035 field repair manual; 100-7008 operator's manual; 500-9006 100 ul pipette; 500-9007 box of pipette tips; 987-0011 hex nut driver; 987-0012 phillip screwdriver
Part Name Assigned BY Controlling Agency: Field service kit chemical analyzer E.I. 6630-01-415-1593.
END Item Identification: Blood analyzer; C/N 95-0335, P/N 100-000, series name: piccolo, nsn 6630-01-415-1593
Defense Logistics Agency (89875)

Quote

00-0250
000250
6630-01-472-9862Analyzer, Clinical ChemistrySpecial Features: Piccolo point-of-care chemistry ANALYZER;(1) 0.1CC minipette, disposable minipette tips (96/PACK); (1) operators manual; (1) power cord; (1) power supply; (10) lithium heparin tubes; (1) screw driver; (2) 15/PACK result cards; piccolo training cd-rom; (1) military storage bin; (1) thermal paper with adhesive back; (1) software interface driver; (10 usb cable; (1) battery back-upower supply; (1) operators manual on cd rom; (1) deployment carrying case; performs multi-analyte panels; tests whole blood, serum or plasma; 100-240 volts ac; 50/60HZ or 15 volts dc, 5.0A, 5-32 degrees
Part Name Assigned BY Controlling Agency: Analyzer chemistry field deployment piccolo point-of-care
Defense Logistics Agency (89875)
Defense Medical Standardization (64616)

Quote

00-0252
000252
6630-01-472-9860Analyzer, BloodGeneral Characteristics Item Description: Spectrophotometric; used in performing wide range of chemical tests for immediate patient care; width 6.000 inches; length 12.000 inches; depth 6.000 inches; power supply shall be battery, either rechargeable or disposable; reusable container shall be furnished if requester wants one
Special Features: Test type for which designed: blood gases and electrolytes analysis; test/measurement range parameters ph, PC02, PO2, na, K, C1, ica, glucose, urea nitrogen, creatinine, hematocrit, hemoglobin, TC02, HC03, be, anion gap, O2 saturation, bun/creatinine ratio
Part Name Assigned BY Controlling Agency: Analyzer blood:
Defense Logistics Agency (89875)
Defense Medical Standardization (64616)

Quote

00039 6630-01-309-5993SeptaNova Biomedical Corp. (59941)

Quote

00-0419
000419
6630-01-476-3178System, gas Chromatograph/Mass SpSpecial Features: System, gas chromatograph/ mass spectrometer; reference number: G202 special purpose; system contains items needed to make gas chromatograph functional; requested nsn from usamma
Part Name Assigned BY Controlling Agency: System gas chromatograph/mass spectrometer system G202
Defense Logistics Agency (89875)

Quote

00-0456
000456
6630-01-478-5577Analyzer, Clinical ChemistrySpecial Features: Compact size table top design; closed tube sampling minimizes risk from blood borne pathogens; positive sample and reagent id-no more specimen and reagent confusion with ace's on-board computer that identifies and tracks samples and reagents by lot number, expiration date, and amount of reagent remaining for an ultra-secure, worry-free system; on-board sample and reagent refrigeration-up to 40 separate test reagents may be stored so effects such as exposure to light and evaporation are kept to an absolute minimum; single proble handles all sample and reagent aspiration and dispense functions; new cuvette for each reaction eliminates chance of cross contamination; immediate stat interrupt; auto repeat and dilution; multi-tasking intelligent software offers individual profile, batch, or stat assays; complete on screen help, color coded prompts and built in self diagnostics that guide every step of the way
Part Name Assigned BY Controlling Agency: Analyzer clin chem kinetic enzyme/rate test
Method OF Analysis: Kinetic enzyme/rate test
Defense Logistics Agency (89875)

Quote

000465 6630-01-520-8345Cup, CalibrationPart Name Assigned BY Controlling Agency: Calibration cup bottom
END Item Identification: Quanta, water quality tester
Hach Company (91224)

Quote

00-0487
000487
6630-01-482-4375Chip, Carbon MonoxideSpecial Features: 5.0 - 150 ppm range; 10 capillary tubes for 10 gas measurements
Part Name Assigned BY Controlling Agency: Chip carbon monoxide 5.0-150PPM range F/use W/6640-01-497-5784
END Item Identification: For use with nsn 6640-01-497-5784 cms electronic detector tube system
Defense Logistics Agency (89875)

Quote

  • We solve sourcing challenges for 00-000920-77 115V, 00-0010, 00-004100-00, 00-011100-00, 00018, 00019, 00-0252, 00039, 00-0456, 00-0487 - NSN parts, hard to find, long lead time and obsolete components.