Chemical Analysis Instruments
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
00-000920-77 115V 0000092077115V | 6630-01-109-3285 | Chromatograph, gas | General Characteristics Item Description: Thermal conductivity type detector, 4 filament wire; single column; 115 vac, 50/60 hz, 1 kw; column oven 8 in. W, 7.5 in. H, 6.5 in. D, temp range ambient to 400 deg c; isothermal proportional temperature controller; solid state bridge/power supply, 0-24 vdc output, 0-300 ma; overall dimensions 17 in. W, 15.75 in. H, 16.25 in. | Varian Associates Inc. (20641) | |
00-0010 000010 | 6630-01-476-4792 | Analyzer, Hematology | General Characteristics Item Description: Power 100/240 volt (less than 120 w), 50/60 hz Special Features: Electronic counting and sizing of cells in triplicate counting with platelet counting and cyanmethemoglobin analysis; capable of performing the following quantitative functions on less than 20 micro liters of whole blood with results in less than 60 seconds; hemoglobin, hematocrit, red blood count inluding red cell indices (mcv, mch, mchc), white blood count with absolute lymphocyte count and per cent lymphocyte of total white blood count, platelet count Part Name Assigned BY Controlling Agency: Blood cell counter: | Defense Medical Standardization (64616) | |
00002 | 6630-01-283-9315 | Electrode, Sodium | Nova Biomedical Corp. (59941) | ||
00-004100-00 0000410000 | 6630-01-016-0412 | Chromatograph, gas | General Characteristics Item Description: Liquid chromatograph, 250 ml solvent capacity, 0 to 5000 psi presure range 0 to 200 ml/hr variable flow rate stainless steel and polytetrafluoroethylene constuction, 115/230 vac, 50/60 hz, 250 watt, high pressure injector, 7 gal capacity water bath, 70 deg C max temp, varian aerograph model A-25 recorder included in assembly, 20 chart speeds, 1MV to 1 V selectable span | Communications & Power Industries (99313) | |
0000 761 000 0000761000 | 6630-01-503-1266 | Analyzer, Clinical Chemistry | Current Type: AC Voltage IN Volts: 220.0 Frequency Rating: 50.0 hertz nominal or 60.0 hertz nominal | Instrumentation Laboratory (HE801) | |
0000761000 | 6630-01-503-1266 | Analyzer, Clinical Chemistry | Current Type: AC Voltage IN Volts: 220.0 Frequency Rating: 50.0 hertz nominal or 60.0 hertz nominal | Instrumentation Laboratory Company (22270) | |
000082904 | 6630-01-263-0725 | Panel, Salinity Indicator | General Characteristics Item Description: Single unit assembly; range of operation 0.50 pm chloride; 21 inches H, 17.5 inches W, 15 inches dp; 60 lbs; alum. housing and electronic assy; used for salt content in water on ship board | Naval Medical Material Support (66736) | |
00-011100-00 0001110000 | 6630-01-074-5629 | Data System, Chromatography | General Characteristics Item Description: 103.5-126.5 vac, 60 hz, 220 W max; operating temp range 10-40 deg c; 16 cm H, 46 cm W, 56 cm d; power cord, recorder cable, instruction manual, printer ribbon, paper roll; stores 9 method files, 127 events max time programmed in A file | Communications & Power Industries (99313) | |
00-011100-00 OPT1560 0001110000OPT1560 | 6630-01-074-5629 | Data System, Chromatography | General Characteristics Item Description: 103.5-126.5 vac, 60 hz, 220 W max; operating temp range 10-40 deg c; 16 cm H, 46 cm W, 56 cm d; power cord, recorder cable, instruction manual, printer ribbon, paper roll; stores 9 method files, 127 events max time programmed in A file | Communications & Power Industries (99313) | |
00012 | 6630-01-271-1373 | Lubricant, Clinical Chemistry Ana | General Characteristics Item Description: 1 oz tube for nova 1 thru 6 analyzers Part Name Assigned BY Controlling Agency: Lubricant clinical chemistry analyzer 1OZ tu nova 1THRU6 analyzr | Nova Biomedical Corp. (59941) | |
00018 | 6630-01-192-9455 | Conditioning Solution, Sodium Ele | General Characteristics Item Description: Etches the glass of the electode to sensitize the elements for ion exchange as well as clean the sensing elements of the electrode to ensure accurate readings; used on nova 1, 4, thru 13 Part Name Assigned BY Controlling Agency: Conditioning sol sodium electrode for use W/nova 4 ANALYZER100ML | Nova Biomedical Corp. (59941) | |
00019 | 6630-01-180-3423 | Wash Solution, Electrode | Special Features: Hazardous ingredient; hypochlorous acid, sodium salt, sodium hypochlorite 0.2 mol/l; soluble; clear colorless to pale yellow liquid; for use W/nova 1 through nova 13 ise analyzers Part Name Assigned BY Controlling Agency: Cleaning solution electrode 50 ml Primary Container Type: Bottle | Nova Biomedical Corp. (59941) | |
00-0214 000214 | 6630-01-473-7416 | Field Service kit, Chemical Analy | Special Features: Piccolo point-of-care chemistry field service kit includes: 998-5007 diagnostic software; 998-5008 diag.softw.installation pkg; 100-5039 lab software; 998-0035 field repair manual; 100-7008 operator's manual; 500-9006 100 ul pipette; 500-9007 box of pipette tips; 987-0011 hex nut driver; 987-0012 phillip screwdriver Part Name Assigned BY Controlling Agency: Field service kit chemical analyzer E.I. 6630-01-415-1593. END Item Identification: Blood analyzer; C/N 95-0335, P/N 100-000, series name: piccolo, nsn 6630-01-415-1593 | Defense Logistics Agency (89875) | |
00-0250 000250 | 6630-01-472-9862 | Analyzer, Clinical Chemistry | Special Features: Piccolo point-of-care chemistry ANALYZER;(1) 0.1CC minipette, disposable minipette tips (96/PACK); (1) operators manual; (1) power cord; (1) power supply; (10) lithium heparin tubes; (1) screw driver; (2) 15/PACK result cards; piccolo training cd-rom; (1) military storage bin; (1) thermal paper with adhesive back; (1) software interface driver; (10 usb cable; (1) battery back-upower supply; (1) operators manual on cd rom; (1) deployment carrying case; performs multi-analyte panels; tests whole blood, serum or plasma; 100-240 volts ac; 50/60HZ or 15 volts dc, 5.0A, 5-32 degrees Part Name Assigned BY Controlling Agency: Analyzer chemistry field deployment piccolo point-of-care | Defense Logistics Agency (89875) Defense Medical Standardization (64616) | |
00-0252 000252 | 6630-01-472-9860 | Analyzer, Blood | General Characteristics Item Description: Spectrophotometric; used in performing wide range of chemical tests for immediate patient care; width 6.000 inches; length 12.000 inches; depth 6.000 inches; power supply shall be battery, either rechargeable or disposable; reusable container shall be furnished if requester wants one Special Features: Test type for which designed: blood gases and electrolytes analysis; test/measurement range parameters ph, PC02, PO2, na, K, C1, ica, glucose, urea nitrogen, creatinine, hematocrit, hemoglobin, TC02, HC03, be, anion gap, O2 saturation, bun/creatinine ratio Part Name Assigned BY Controlling Agency: Analyzer blood: | Defense Logistics Agency (89875) Defense Medical Standardization (64616) | |
00039 | 6630-01-309-5993 | Septa | Nova Biomedical Corp. (59941) | ||
00-0419 000419 | 6630-01-476-3178 | System, gas Chromatograph/Mass Sp | Special Features: System, gas chromatograph/ mass spectrometer; reference number: G202 special purpose; system contains items needed to make gas chromatograph functional; requested nsn from usamma Part Name Assigned BY Controlling Agency: System gas chromatograph/mass spectrometer system G202 | Defense Logistics Agency (89875) | |
00-0456 000456 | 6630-01-478-5577 | Analyzer, Clinical Chemistry | Special Features: Compact size table top design; closed tube sampling minimizes risk from blood borne pathogens; positive sample and reagent id-no more specimen and reagent confusion with ace's on-board computer that identifies and tracks samples and reagents by lot number, expiration date, and amount of reagent remaining for an ultra-secure, worry-free system; on-board sample and reagent refrigeration-up to 40 separate test reagents may be stored so effects such as exposure to light and evaporation are kept to an absolute minimum; single proble handles all sample and reagent aspiration and dispense functions; new cuvette for each reaction eliminates chance of cross contamination; immediate stat interrupt; auto repeat and dilution; multi-tasking intelligent software offers individual profile, batch, or stat assays; complete on screen help, color coded prompts and built in self diagnostics that guide every step of the way Part Name Assigned BY Controlling Agency: Analyzer clin chem kinetic enzyme/rate test Method OF Analysis: Kinetic enzyme/rate test | Defense Logistics Agency (89875) | |
000465 | 6630-01-520-8345 | Cup, Calibration | Part Name Assigned BY Controlling Agency: Calibration cup bottom END Item Identification: Quanta, water quality tester | Hach Company (91224) | |
00-0487 000487 | 6630-01-482-4375 | Chip, Carbon Monoxide | Special Features: 5.0 - 150 ppm range; 10 capillary tubes for 10 gas measurements Part Name Assigned BY Controlling Agency: Chip carbon monoxide 5.0-150PPM range F/use W/6640-01-497-5784 END Item Identification: For use with nsn 6640-01-497-5784 cms electronic detector tube system | Defense Logistics Agency (89875) |