Chemical Analysis Instruments: BBK 834014, BECKMAN COULTER AUTOMATED HMX, BP0018
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
BBK 834014 BBK834014 | 6630-01-301-5636 | Pump, Ion Vacuum | General Characteristics Item Description: Used to maintain A vacuum on A laser calorimeter standard when calibrating laser power and energy meters; min pump speed of 11 L/second; pressure of 10-7 torr or less; flange size id/od 1.5/2.75 in.; 10 X 10 X 10 in; 25 lbs; 120 v; single phase; 60 hz; analog display meter | Air Force Medical Logistics Office (66735) | |
BBL60415 | 6630-01-154-1697 | Timer, Blood and Plasma Coagulati | General Characteristics Item Description: 115 volt, 60 hz; includes six warming wells; one reaction well; on-off switch; reset button; electric pipet; electro mechanical clot sensing device; 400 disposable reaction cups and A 6 ft. 3-WIRE cord with plug; for performing all assays that have A fibrin end point including prothrombin time, and partial thromboplastin time; for use with blood and plasma coagulation timer reagent cup, 6630-01-032-4238 and pipet tip, 6640-00-902-0810 Part Name Assigned BY Controlling Agency: Timer blood and plasma coagulation fibrometer 115V 60HZ Unit OF Issue Cube: 0.822 cubic feet | Becton-Dickinson and Co. (05545) | |
BC0177 | 6630-01-337-2991 | Sensor, Vacuum, Blood gas Analyzer | General Characteristics Item Description: For use on blood gas analyzer; model 990/990S Part Name Assigned BY Controlling Agency: Sensor vacuum blood gas analyzer E.I. nsn 6630012066035 END Item Identification: 6630-01-206-6035 | AVL Scientific Corporation (1HU53) | |
BD-20 110 VOLT BD20110VOLT | 6630-01-016-0420 | Digestion Apparatus, Nitrogen Det | Current Type: AC Voltage IN Volts: 110.0 Frequency Rating: 50.0 hertz minimum and 60.0 hertz maximum | Bayer Corp. (59426) | |
BD-20 220 VOLT BD20220VOLT | 6630-01-016-1531 | Digestion Apparatus, Nitrogen Det | Current Type: AC Voltage IN Volts: 220.0 Frequency Rating: 50.0 hertz minimum and 60.0 hertz maximum | Bayer Corp. (59426) | |
BD-40 110 VOLT BD40110VOLT | 6630-01-016-1532 | Digestion Apparatus, Nitrogen Det | Current Type: AC Voltage IN Volts: 110.0 Features Provided: Glassware and wire glassware support | Bayer Corp. (59426) | |
BD424241 | 6630-01-233-7594 | Capillary Centrifugal Hematology | General Characteristics Item Description: 100 tubes; 100 floats; 100 tube closures, performs 100 capillary hematocrits white blood cell counts, platelet counts, and partial differential determinations; for use W/analyzer centrifugal hematology, 6640-01-234-6793 and 6640-01-234-6794; unit qty 100 Special Features: To perform microhematocrit Part Name Assigned BY Controlling Agency: Capillary centrifugal hematologh tube | Infolab Inc. (0CG54) | |
BD6509 | 6630-01-321-5290 | Tube, Blood Collecting | Overall Length: 75.0 millimeters nominal Features Provided: Prelabeled and vacuum Special Features: W/polymer gel and clot activator | Becton Dickinson and Company (06531) | |
BECKMAN COULTER AUTOMATED HMX BECKMANCOULTERAUTOMATEDHMX | 6630-01-537-8373 | Analyzer, Hematology | Special Features: Provides for safer handling of patient samples without risk of contamination; automated hematology analyzer that provides automatic handling; automated sampling and A 5-PART defferential of the white blood cell types; auto cap-piercing Part Name Assigned BY Controlling Agency: Analyzer hematology auto-loading cap-piercing hmx | Beckman Coulter Inc. (6Z677) | |
BIO-FLO BIOFLO | 6630-01-056-9557 | Autoclave, Culture, Apparatus | General Characteristics Item Description: Has culture vessel working volumn 350 ml approx., temp range -20 to 151 deg. C. agitation speed 200 to 1, 000 rpm, aeration-adjustable up to 800 ml/min, medium flow-adjustable 10-300 ml, reserviors-two supplied medium storage 13.3 liters, dimensions CONSOLE-HEIGHT-21 in., front to BACK-17.250 in., WIDTH-15.250 in., 115 V 60 hz fused at 5 amps, 220 V 50 hz fused at 3 amps | New Brunswick Scientific Co. Inc. (14858) | |
BIO/PHYSICS SYSTEMS 6300A BIOPHYSICSSYSTEMS6300A | 6630-01-059-4465 | Cytograph | General Characteristics Item Description: 3 photosensors, internal oscilloscope; 2 digital displays, 5 digit; determines cell concentration, generates cytogram and differential count | Ortho Diagnostic Systems Inc. (56696) | |
BIO/PHYSICS SYSTEMS CYTOGRAF BIOPHYSICSSYSTEMSCYTOGRAF | 6630-01-059-4465 | Cytograph | General Characteristics Item Description: 3 photosensors, internal oscilloscope; 2 digital displays, 5 digit; determines cell concentration, generates cytogram and differential count | Ortho Diagnostic Systems Inc. (56696) | |
BK39273 | 6630-00-494-3668 | Electrode, Ph | Special Features: Platinum button element composition; 5 in. O/A lg excl lead 30 in. lg lead; platinum type; 0 to 100 deg C optimum temp range of solution; telephone type connector; body shielded; accessories 1 connector Unit OF Issue Cube: 0.05 cubic feet Unit OF Issue Weight: 1.00 pounds | VWR Scientific Inc. (65662) | |
BK511005 | 6630-01-537-6007 | Meter, Ph | Reference Number Differentiating Characteristics: Material will be in accordance with navicp activity hx quality control, manufacturing and testing specification Criticality Code Justification: ZZZY | VWR Scientific Products Corp. (0UA56) | |
BKM 06 001 BKM06001 | 6630-01-262-0469 | Analyzer, gas | Balzers Corp. (59811) | ||
BK M07 509 BKM07509 | 6630-01-263-6620 | Analyzer, Quadrupole | Balzers Corp. (59811) | ||
BLOOD ANALYZER(I-STAT) BLOODANALYZERISTAT | 6630-01-504-2815 | Analyzer, Blood | Special Features: Hportable; cartridge-based; for blood, gas, eletrolyte analyzer; for field use environment; has A reusable shipping container; uses plastic discs containing all the reagents and diluents needed testing Part Name Assigned BY Controlling Agency: Blood analyzer W/reusable shipping container | Defense Logistics Agency (89875) | |
BM756PC14 | 6630-00-025-5362 | Conductivity Cell, Battery Water | Rosemount Analytical Inc. (30646) | ||
BMS3MK2 | 6630-01-087-3367 | Blood Micro System | General Characteristics Item Description: Sample volume 30 ul, response time 15 sec, range 0-10 ph units, 4 equilibration chambers, 6 L water bath, circulation pump, suction pump, 97 percent plus electrode sensitivity, 115VAC, 47.5-63 hz, 325 va, 310 mm H X 310 mm W X 370 mm D, aluminum case, electrodes, buffer solutions, blood sampling kit for 75 capillary samples, nomograms, plastic cover, operating instructions | Radiometer America Inc. (53727) | |
BP0018 | 6630-01-528-9141 | Solenoid, Electrical | END Item Identification: 6630015289109 | AVL Scientific Corporation (1HU53) |