Chemical Analysis Instruments: A91D137, A91L106, AA-3
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
A91D137 | 6630-01-343-8184 | Wash Solution, Clinical Chemistry | Special Features: Used with ciba corning 280 and 288 blood gas system Part Name Assigned BY Controlling Agency: Wash solution clin chem analyzer 750 ml U/W ciba corning 280 & 288 Primary Container Type: Bottle | Department of the Army (66732) | |
A91L106 | 6630-01-353-5670 | Electrode, Partial Oxygen | Special Features: Clark design; optimum temperature range 37 deg c; oxygen permeable membrane; silver anode, platinum cathode; used on avl blood gas analyzers Instrument Type FOR Which Designed: Blood gas analyzer Body Material: Glass | Department of the Army (66732) | |
A91L121 | 6630-01-354-8720 | Wash Solution, Clinical Chemistry | Special Features: Cleaning solution b; 100ML antarox bl, NAHC03, nacl; odorless; colorless; used on avl blood gas analyzers Part Name Assigned BY Controlling Agency: Wash solution clinical chemistry analyzer liquid 100 ml Physical Form: Liquid | Department of the Army (66732) | |
A91L122 | 6630-01-354-8721 | Wash Solution, Clinical Chemistry | Special Features: 1ML dehdol 100 and dehydran 241 per ampule; 100 ampules per pkg; odorless; colorless; one ampule per 3/4 rinse water; used on avl blood gas analyzers Part Name Assigned BY Controlling Agency: Wash solution clinical chemistry analyzer liquid 1ML 100S Physical Form: Liquid | Department of the Army (66732) | |
A91L224 | 6630-01-353-1064 | Cup, Sample, Automated Analysis | Special Features: For use W/acl automated coagulation system Part Name Assigned BY Controlling Agency: Cup sample automated analysis .500ML 1000S Primary Container Type: Package | Department of the Army (66732) | |
A91L264 | 6630-01-357-6705 | Wash Solution, Automated Analyzer | General Characteristics Item Description: 17 mmols per liter; contains A mold inhibitor; used to clean and flush sample path line; for use W/il's co-oximeters; unit qty: ten 500 ml bottles per pkg Part Name Assigned BY Controlling Agency: Wash solution automated analyzer 500ML 10S | Department of the Army (66732) | |
A92052 | 6630-01-365-4750 | Tubing, Clinical Chemistry Analyz | Special Features: Connects liquid heater block to probe connector of abbott imx immunoassay analyzer Part Name Assigned BY Controlling Agency: Tubing clin chem analyzer conn liq heater box to probe connector | Department of the Army (66732) | |
A-9226 A9226 | 6630-01-128-0387 | Adapter, Oxygen Analyzer | Special Features: Plastic; L-shape; flow-thru; 2 port; 3 in. h; 3 in. w; pneumatic sampling of gas atmospheres used with 320 series oxygen analyzers | Koch J Associates Inc. (4P648) Teledyne Instruments Inc. (21070) | |
A92A082 | 6630-01-354-3135 | Housing, Valve, Clinical Chemistry | General Characteristics Item Description: Plastic with rubber membrane; used to cover gas valve of avl 990 and 995 blood gas analyzers or electric valve of avl 912 co-oximeter Part Name Assigned BY Controlling Agency: Housing valve clinical chemistry analyzer | Department of the Army (66732) | |
A92A104 | 6630-01-353-3804 | Tubing, Clinical Chemistry Analyz | Special Features: Replacement part for technicon H-1 and H-2 hematology analyzers; 10 ft per package Part Name Assigned BY Controlling Agency: Tubing clinical chemistry analyzer 10' per package Primary Container Type: Package | Department of the Army (66732) | |
A92A108 | 6630-01-354-3195 | Tubing, Blood gas Analyzer | Special Features: Used on avl blood gas analyzers 990, 995, and 945 with serial no. greater than 1300 Part Name Assigned BY Controlling Agency: Tubing blood gas analyzer silicone rubber Overall Length: 4.410 inches nominal | Department of the Army (66732) | |
A92D468 | 6630-01-362-2037 | Cup, Sample, Automated Analysis | Special Features: For use W/il's acl 300, 300 plus, 200, 100, and 810 coagulation systems Part Name Assigned BY Controlling Agency: Cup sample automated analysis plas 2ML 1000S Primary Container Type: Package | Department of the Army (66732) | |
A92J029 | 6630-01-370-3221 | Pipet-Diluent, Blood, Laboratory | Special Features: White cell test; polyethylene reservoir contains 1.98 ml 3 pct acetic acid for 1:100 dilution; for use on hemacytometer Material: Glass Capacity: 20.0 microliters | Department of the Army (66732) | |
A94I001 | 6630-01-390-1296 | Holder, Blood Collecting Tube | Special Features: Tube diameter is 3/4 inch at top, 5/8 inch at end. cturer 50 bags per case, each bag consisting of: 1-NEEDLE holder, and 6-DISPENSER racks containing 10 disposable threaded ends. ing buttons for disposing threaded end and needle in waste container. Part Name Assigned BY Controlling Agency: Holder blood collecting tube plas disp 2.250 O/A lg 50S Overall Length: 2.250 inches nominal | Department of the Army (66732) | |
A97 TCM097 A97TCM097 | 6630-01-348-5100 | Chromatograph, gas | General Characteristics Item Description: 115 volts; aluminum housing; 10-1/2 in. H X 13-3/4 in. W X 11 in. d; 296 cubic inch capacity; 50 deg C to 300 deg C temperature range; accomodates two detectors operating separately or in series configuration; operable with seven different detectors: photoionization detector (pid), flame ionization detector (fid), thermal conductivity detector (tcd), far ultraviolet absorbance detector (fuva), nitrogen/phosphorous detector (npd), electron capture detector (ecd), and electrolytic conductivity detector (ecd); accommodates three types of injectors: two packed injectors in the heated block or one capillary injector and one packed column injector; pneumatic system for controlling carrier gas flow rates Special Features: Iincludes separate Z-80 microprocessor-based temperature controller with keypad and printer; 5-1/2 in. H X 9-1/4 in. W X 10-3/4 in. d; 50 deg C to 300 deg C temperature programming in 1 deg C increments | Department of the Army (66732) | |
A-988 A988 | 6630-00-420-0507 | Test kit, Alkacid Full Range Ph | General Characteristics Item Description: C/O pocket size plastic box, containing one dispenser W/alkacid wide range test paper and six dispensers W/short range test papers, ph ranges 0.0 to 3.0, 3.5 to 5.5, 6.0 to 8.5, 9.0 to 11.0, 10.5 to 12.5 and 12.0 to 14.0, color key provided on each dispenser | Fisher Scientific Co. (19631) | |
A988 | 6630-00-420-0507 | Test kit, Alkacid Full Range Ph | General Characteristics Item Description: C/O pocket size plastic box, containing one dispenser W/alkacid wide range test paper and six dispensers W/short range test papers, ph ranges 0.0 to 3.0, 3.5 to 5.5, 6.0 to 8.5, 9.0 to 11.0, 10.5 to 12.5 and 12.0 to 14.0, color key provided on each dispenser | Fisher Scientific Company LLC (22527) | |
A-9900 A9900 | 6630-01-254-4117 | Cap, Probe Assembly | General Characteristics Item Description: Nylon; outside diameter 1.5625 in., inside diameter 1.4625 in.; W/0.81 in. diameter filter screen and gasket; attaches to probe assembly; for use W/oxygen detector model 320 | Teledyne Instruments Inc. (21070) | |
A-A-2582 AA2582 | 6630-00-171-5126 | Tester, Battery Electrolyte Solut | Part Name Assigned BY Controlling Agency: Tester battery electroylyte sol gravity range 1.100 to 1.350 Thermometer: Included Specific Gravity Range: +1.100/+1.350 | ||
AA-3 AA3 | 6630-01-038-1201 | Analyzer, Chemiluminescence | General Characteristics Item Description: Measures concentration of oxides of nitrogen or ozone; built-in ozone generator and sampling pump; linear over range of 0.004 to 1000 ppm; internal nitrogen dioxide converter; 2 sonic orifice flowmeters; 9 full scales 0.1, 0.25, 1, 2.5, 10, 25, 100, 250, 1000 ppm switch selected; 115 vac, 60 hz, 450 w; aluminum case; 31 cm H, 48 cm W, 58 cm D | Aerochem Research Laboratories Inc. (26884) |