Chemical Analysis Instruments: 1C3903G1, 1P0564772132, 2003-1074

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
1C3903G1 6630-00-962-8976Test kit, Oil ConditionPart Name Assigned BY Controlling Agency: Lube oil system tester
Functional Description: Used to indicate lube oil system pressure, temperature and fuel contanination
Unpackaged Unit Height: 10.000 inches nominal
General Electric Co. (24446)
General Electric Company (07482)

Quote

1CCN8 6630-00-938-2241Cell and Valve AssemblyGeneral Characteristics Item Description: Ty gate; sz 1-1/4 in.; matl bronze; end connections, socket weld W/rings and connecting nipples; rated steam pressure; 30 in. hg to 150 psi at 250 deg F (max); hydro test pressure; 225 psi at ambient, time 10 min. leakage at 12.5 cm/min, max
Marine Electric Systems Inc. (00062)

Quote

1CCN8S3SM0D 6630-00-983-2578Cell, Salinity IndicMarine Electric Systems Inc. (00062)

Quote

1H0261 6630-01-542-5510Lubricant, Smpl PmpEND Item Identification: Analyzer, clinical C
Ortho-Clinical Diagnostics Inc. (03KD1)

Quote

1-HAP-11022
1HAP11022
6630-01-460-0664Field Rugged Gc MsSpecial Features: Lthe field rugged gc/ms is A man-portable, lightweight, battery powered, 110 VOLT/200 watt, down-range deployable gas chromatograph/mass spectrometer. the field rugged gc/ms is capable of low level detection of volatile organic compounds (voc) in the parts per billion (ppb) range. the field rugged gc/ms provides on-site qualitative and quantitative field screening results, built-in shoulder strap or backpack, internal computer hard drive and direct sampling system
Inficon Inc. (56507)

Quote

1K36 6630-00-405-2907Rule, Viscosity ConvPacific Scientific Co. (96173)

Quote

1P0564772111 6630-01-496-8537Standard, CalibratioAlcor Petroleum Instruments Inc. (05647)

Quote

1P0564772132 6630-01-496-8539Standard, CalibratioAlcor Petroleum Instruments Inc. (05647)

Quote

1R001FE 6630-01-331-1992Analyzer, gasQuantitech LTD (U2735)

Quote

1R001FE 6630-01-369-6649Analyzer, gasCurrent Type: AC
Voltage IN Volts: 120.0
Frequency IN Hertz: 50.0 or 60.0
Foxboro Co., The (23439)

Quote

1XX*VP00S
1XXVP00S
6630-01-384-9387Pin, Blood CollectingGeneral Characteristics Item Description: Plastic; disposable; clear; piercing sampler designed specifically for use with the venoject ii plastic bloodcollection tube with ultraseal closure; 5000S (500 per box, 10 boxes per case
Terumo Medical Corp. (54946)

Quote

2 6630-00-255-8057Comparator, Viscosity, OilSpecial Features: Range for close reading, 200 to 800 saybolt seconds
Unit OF Issue Cube: 0.071 cubic feet
Accessory Components AND Quantity: 1 set operating instructions
Louis C Eitzen Company Inc. (19657)

Quote

2 6630-00-527-6149Hydrometer, Graduated ScaleOverall Length: 14.000 millimeters minimum and 18.000 millimeters maximum
Thermometer: Included
Scale Quantity: 1
G M Mfg Co. (23857)

Quote

200 6630-00-560-6319Test Clip, AnalyzerGeneral Characteristics Item Description: Ic type, complete with ten 16 pin sockets, 40 programming pins, logic probe and manual, carrying case
Fluke Corporation (89536)

Quote

200 6630-00-629-0207Sampler, Aerosol AnalyticalGeneral Characteristics Item Description: 8 in.W, 18 in.lg, 14 in.H, aluminum case 110V ac or 24V dc input primarily tests organic phosphor vapor
Environmental Researach Corp. (34590)

Quote

200 6630-00-986-6230Analyzer, gasCurrent Type: AC
Voltage IN Volts: 110.0
Functional Description: Lira model 200 luft type infrared analyzer for gas or liquid analysis for use in production areas to monitor product quality, explosive concentrations, etc
Mine Safety Appliances Company (55799)

Quote

200 6630-01-018-6316Impactor, Particle CascadeGeneral Characteristics Item Description: Multi-stage, fractionates suspended particulates into as many as 6 size ranges, wih digital display
Reference Number Differentiating Characteristics: As differentiated by digital display
Hach Ultra Analytics Inc. (53882)

Quote

2000 6630-00-431-4750Meter, PhSpecial Features: RANGE0 to 13 ph; 0 to 1300 mv
Overall Length: 11.000 inches nominal
Overall Width: 8.000 inches nominal
Beckman Coulter Inc. (80740)

Quote

2000 6630-00-611-5012PlethysmographGeneral Characteristics Item Description: 6CONSISTS of console housing converter, displaymodules and related components including A 15 in. by 21 in. writingsurface, basrc enclosure dim 22 in. H by 22-1/2 in. dep by 22 in. W, power requirement 115 volt, 50 to 60 hz, 0.4 amperes, ac or dc cujrent
Cardio-Pulmonary Instruments Div. Of (32817)

Quote

2000 6630-01-011-8527Photometer, Adenosine TriphosphatGeneral Characteristics Item Description: 115 and 230 vac porm 10 pct., 48-440 hz, 24 w; recorder output 0-10 V max, 10 K impedance; 7 in. W, 11 in. H, 11.5 in. d; range 0.000000001 mg atp/ml to 1 mg atp/ml; assay speed 75 sec; sample vol range 10 microliters to 10 ml
L-3 Communications Corporation (08YX1)

Quote

2000 6630-01-017-6722Analyzer, Blood ChemistryGeneral Characteristics Item Description: Solid state filter photometer, 3 cuvet holding wells, 1 kept at ambient temperature, 1 at 37 degs C, 1 heated to 95 degs C, dimensions 12-3/4 in. by 12 in. by 5 in., 110 volts ac, 60 hz
Becton Dickinson and Co. (12717)

Quote

2000 6630-01-086-6936Meter, Ozone ConcentrationGeneral Characteristics Item Description: Ranges 0-0.1, 0-0.2, 0-0.5, 0-1 ppm; temp range 10-40 deg C, humidity range 5-95 pct.; ethylene consumption 7 cc/min, air sample flow rate 700 cc/min, automatic fault diagnostic system, analog panel meter W/audible alarm; 8 in. W, 7 in. H, 18 in. D
Columbia Scientific Industries Corp. (54240)

Quote

2000 6630-01-165-7126Analyzer, AlcoholSpecial Features: 3.0 amp
Overall Width: 20.000 inches nominal
Overall Height: 9.000 inches nominal
Draeger Safety Inc. (53833)
Smith and Wesson Chemical Co. Inc. (52036)

Quote

2000 6630-01-218-5081Test set, Exhaust gas AnalysisSpecial Features: Computer, combustion efficiency, temperature range 0-1999 deg F., fuel selections coal no. 2 and 6, oil, natural gas, and propane, PRINTER/3 inch thermal paper, 40 characters per line, 115 vac, 60 hz or rechargeable ni-cad batteries, portable aluminum case, consists of water trap, smoke chart and test paper
Unpackaged Unit Height: 9.000 inches nominal
Unpackaged Unit Width: 12.000 inches nominal
Energy Efficiency Systems Inc. (62540)

Quote

20-000
20000
6630-01-048-6756Sampler, Air ParticulateGeneral Characteristics Item Description: Aerodynamic sizing of particles from 11 microns and above to 0.4 microns in 8 anodized aluminum stages; impactor 7.75 in. H, 4.25 in. dia., 400 jets/stage except stage 7 with 200 jets, jet dia. range from 0.0625 to 0.01 in., 12 quartz collection plates; mtg base with carrying case cover, O-ring gasket; 1 cfm flow at 1 in. mercury
Andersen Samplers Inc. (58036)

Quote

2001 6630-01-531-5762Analyzer, Clinical ChemistrySpecial Features: 25 biochemistry parameters available to run, including T4 and electrolytes, users can run any combination of chemistries from 1 single test to A full 25 chemistry profile
Part Name Assigned BY Controlling Agency: Prochem V
Drew Scientific Inc. (1ESE4)

Quote

200201 6630-01-374-0340Specimen kit, UrineSpecial Features: Nonsterile; disposable
Component Quantity: 5
Nonsupply Items AND Quantities: Specimen collection cup, 1000; specimen tube, plastic, 1000; snap cap for tube, specimen, 1000; label, identification, 1000; rack tube, 1
Thermo Shandon Inc. (17602)

Quote

20-0275
200275
6630-00-973-4964Meter, gas AnalyzerSpecial Features: Selected and tested for use on electrolytic oxygen-nitrogen generator cleaned in accordance W/MIL-P-52211/CE/
Avox Systems Inc. (53655)

Quote

200280 6630-01-111-0826Test kit, Oil Acid DeterminationGeneral Characteristics Item Description: One step test for acid in oil; C/O bottle with measured amount of test liquid 1, color comparator 1
Alter Harry Co., The (70334)

Quote

2003-0501
20030501
6630-01-507-0899Coagulation AnalyzerGeneral Characteristics Item Description: Extensive test menu with clotting, chromogenic and immunologic capabilites; clot curve analysis evaluates abnormal or unexpected test results; reflex testing standardizes the decision rules; automated rotor changer delivers 18 tests in 7.5 minutes; easy to use touch screen. continuous loading with stat interrupt; on board capacity for 40 samples and 18 reagents
Part Name Assigned BY Controlling Agency: Acl 9000 coagulation analyzer
Supplementary Features: Freequency rating 50-60 hz(nominal)
Defense Logistics Agency (89875)

Quote

2003-1074
20031074
6630-01-508-9265Evaporator, LaboratoryGeneral Characteristics Item Description: Comprised of the following components: evaporator manifold unit attached luer-lok tips, two-way valve, and black screw knop. nine 2.5 inch stainless steel needles with luer-lok hubs. nine stainless steel plugs with luer-lok tips. twelve inch length, 0.5 inch diameter metal rod. bottom mounting bracket assembly: includes mounting bracket with attached black screw knob. four machine screws for attachment, and one self-threating.
Part Name Assigned BY Controlling Agency: Reacti-vap evaporator
Defense Logistics Agency (89875)

Quote

  • We solve sourcing challenges for 1C3903G1, 1CCN8S3SM0D, 1-HAP-11022, 1K36, 1P0564772111, 1XX*VP00S, 2, 20-000, 200280, 2003-1074 - NSN parts, hard to find, long lead time and obsolete components.