Chemical Analysis Instruments: 15-4053, 1570, 15802-D

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
15-4053
154053
6630-01-022-6112Monitor, EnvironmentGeneral Characteristics Item Description: Humidity, temperature and light intensity 3 channel type, power required 115 volt, 60 hz, 60 watts
Newport Scientific Inc. (11877)

Quote

15-420-2Q
154202Q
6630-01-012-4093Test Paper, Chlorine DeterminatioGeneral Characteristics Item Description: C/O dispenser;color chart range of 10-50-100-200 ppm; test PAPER-2 rolls; size 15 ft lg; 5/32 in. w; sufficient for 200 tests; used for determination of chlorine; unit qty 10
Part Name Assigned BY Controlling Agency: Test paper chlorine determin range 10-50-100-200 PARTS/MILLION10
Unit OF Issue Cube: 0.0130 cubic feet
Fisher Scientific Company LLC (22527)

Quote

1549-1
15491
6630-01-026-2645Module, TemperatureGrundy Environmental Systems Inc. (58087)

Quote

154D 6630-00-967-0490Analyzer, OxygenSpecial Features: Efractometer, vapor, consists of precision temperature controller, column chamber, thermister, conductivity detector, flowmeter, pressure regulator with gage, heated sample outlet, and tubes, 75 lbs
Overall Width: 20.000 inches nominal
Overall Height: 12.000 inches nominal
Applied Biosystems LLC (46555)

Quote

1550 6630-00-555-1001Nephelometer, IntegratingGeneral Characteristics Item Description: 3 ranges selectable to match the prevailing degree of pollution, temperature compensated 0 to 130 deg F
Meteorology Research Inc. (22260)

Quote

155021 6630-01-283-9499Carbon Dioxide Analyzer kitGeneral Characteristics Item Description: Consists of specially designed aspirator sampling equipment and steel carrying case; carbon dioxide scale range 0 to 20 percent; for use in checking the critical carbon dioxide percentage concentration in incubator, bacteriological; 6640-01-251-5472; cage code 04567; part no. 3158
Thermo Forma Inc. (1AC83)

Quote

15507 6630-01-439-9678Lactate Membrane KiNova Biomedical Corp. (59941)

Quote

1550-C
1550C
6630-01-521-7806Tester, Antifreeze SolutionsSpecial Features: Test strips, antifreeze, awpag
END Item Identification: Asos weather system
Acustrip Co. Inc. (1ZF89)

Quote

15566TS-1
15566TS1
6630-00-507-0584Test set Assembly, Oxygen-NitrogeGeneral Characteristics Item Description: Measures the oxygen and nitrogen purities by chemical reaction and indicates the pourity on A direct reading burette
Process Supply Inc. (63479)

Quote

1561 6630-01-071-6574Nephelometer, IntegratingGeneral Characteristics Item Description: Local visual distance 50.0-2.5 miles, scattering coefficient 0-10, mass concentration 0-380, accuracy porm 10 pct.; vertical or horizontal mtg, 104.1 cm H, 33 cm W, 20.3 cm d; 105-125 vac, 60 hz, 60 W max, operating temp range M18-54 deg c; aluminum case; 5 cfm air sampling pump
Meteorology Research Inc. (22260)

Quote

156-1070
1561070
6630-01-594-4696Analyzer, gasCaterpillar Inc. (11083)

Quote

156225 6630-01-588-5702Test set, SoilPart Name Assigned BY Controlling Agency: Soil resistivity kit
END Item Identification: Italian air force
Farwest Corrosion Control Co. (4X592)

Quote

1562-3
15623
6630-01-028-9915Module Oscillator sGrundy Environmental Systems Inc. (58087)

Quote

156-869
156869
6630-01-367-1124Tubing, Clinical Chemistry AnalyzCurtin Matheson Scientific Inc. (15481)

Quote

156-AP1
156AP1
6630-01-397-5017Test set, Water Turbidity and ColPart Name Assigned BY Controlling Agency: Analite kit 160
END Item Identification: 6630-01-343-8495, water quality analysis set
APS Analytical Standards Inc. (0F0F0)

Quote

1570 6630-01-065-6987Monitor, ChlorineGeneral Characteristics Item Description: 8MEASUREMENT range 0.001-10 ppm chlorine; sample requirements 3 L/min, 20-100 psig, 10-40 deg c; 1 reagent charge for every 750 hrs of operation; process interface 0.25 in. nptf W/check valve; 100/115/220/240 vac, 50/60 hz, 5 w; 118 cm H, 30 cm W, 13 cm D
Thermo Orion Inc. (30260)

Quote

1570 6630-01-075-3139Monitor, ParticulateGeneral Characteristics Item Description: Pflue gas temp range M17.8-260 deg C, velocity range 5-75 ft/sec; ambient temp range M23.3-48.9 deg c; output 0-5 vdc, flue diameter range 1-30 ft., accuracy porm 15 pct.; 115 vac, 50/60 hz, 0.5 A max; 90.2 cm H, 69.8 cm W
Meteorology Research Inc. (22260)

Quote

157001 6630-01-065-6987Monitor, ChlorineGeneral Characteristics Item Description: 8MEASUREMENT range 0.001-10 ppm chlorine; sample requirements 3 L/min, 20-100 psig, 10-40 deg c; 1 reagent charge for every 750 hrs of operation; process interface 0.25 in. nptf W/check valve; 100/115/220/240 vac, 50/60 hz, 5 w; 118 cm H, 30 cm W, 13 cm D
Thermo Orion Inc. (30260)

Quote

15706 6630-01-581-8379Gas Chromatograph-Mass SpectromeSpecial Features: Gc/msd bundled system; triple axis hed-em detector; system includes: agilent 7890A series gc custom, 5975C inert xl msd per performance turbo ei, nist 2008 ms library bundle, pesticide ms spectral library, msd productivity chemstation software, 7693A autoinjector, 7890 ltm bundle, agilent ltm control software, hardigg cade and mounting plate, hewlett-packard elitebook 8530P notebook, inert ion source assembly, 5975 350 inert analyzer
Part Name Assigned BY Controlling Agency: Gas chromatograph mass spectrometer bundled system
Defense Logistics Agency (89875)

Quote

1580 6630-01-012-4451Sampler, Effluent WasteGeneral Characteristics Item Description: Pump rate 1480 ml per inute at 2.25 ft A second with 1/4 in. id line, size 25-1/2 in. H by 19 in. dia, with internal battery, with removable 117 volt ac power converter
Isco Inc. (23307)

Quote

15802-D
15802D
6630-01-176-4613Meter, Module, Salinity IndicatingGeneral Characteristics Item Description: Designed for ic/sb salinity system; range 0 to 10 ppm of chloride
McNab Incorporated (39425)

Quote