Chemical Analysis Instruments: 112210, 113S2, 115000
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
112210 | 6630-01-487-8851 | Kit, pc Download | Special Features: Pc download kit used to upgrade the software on the analyzer which will occur 3 timer per year; ir link is also used as an interface the analyzer to the hp portable printer Part Name Assigned BY Controlling Agency: Kit pc download (1)IR link pwr adapt (1) 5'CABLE 2KEYBRD adapter END Item Identification: For use with end item 6630-01-411-2405 | I-Stat Corporation (00WB2) | |
1122423 | 6630-01-517-8938 | Liner, Disposable box, Analyzer | Special Features: For use with 250/750/950 chemistry analyzer; disposable; pkg. of 100 liners Part Name Assigned BY Controlling Agency: Slide disposable box liner chemistry analyzer 100S END Item Identification: Vitros 250 chemistry analyzer, NSN:6630-01-441-5297 | Ortho-Clinical Diagnostics Inc. (03KD1) | |
112515 | 6630-00-279-5579 | Magnetic unit, Oxyge | Newington Electric Co. Inc. (05721) | ||
11272 | 6630-01-180-3423 | Wash Solution, Electrode | Special Features: Hazardous ingredient; hypochlorous acid, sodium salt, sodium hypochlorite 0.2 mol/l; soluble; clear colorless to pale yellow liquid; for use W/nova 1 through nova 13 ise analyzers Part Name Assigned BY Controlling Agency: Cleaning solution electrode 50 ml Primary Container Type: Bottle | Nova Biomedical Corp. (59941) | |
112L428G1 | 6630-00-126-7971 | Counter, Condensati | General Electric Co. (24446) | ||
11305 | 6630-01-603-8208 | Filter Element, Fluid | Reference Number Differentiating Characteristics: Material will be in accordance with navsup-wss activity hx quality control, manufacturing and testing specifications Criticality Code Justification: ZZZY | Graver Technologies LLC (32857) | |
113-3719-01 113371901 | 6630-01-368-6272 | Filter, Clot, Hematology Analyzer | General Characteristics Item Description: White disk; located near sampling area; used to prevent clots from entering the instrument; for use W/H-2, H-1, H-1E, H-1 jr hematology analyzers | Bayer Corp. (59426) | |
11-388 11388 | 6630-01-049-9071 | Glass Wool, Long Fib | Fisher Scientific Company LLC (22527) | ||
11390-01 1139001 | 6630-01-445-5139 | Adapter, Vial | General Characteristics Item Description: Lifeshield prepierced reseal vial adapter; allows vial access (13-20MM) when using lifeshiled blunt cannula; unit qty pg of 200 Part Name Assigned BY Controlling Agency: Adapter vial | Century Medical Supply (0NLH6) | |
113979-0003 1139790003 | 6630-01-086-1856 | Analyzer, Sulfur | General Characteristics Item Description: 24IN. L X 19IN. W X 9IN. H, automatic, flame photo detect, dual range, 115V, 60HZ, 0-100PPB and 0-1PPM, output 0-1MV and 0-5VFS | BAE Systems Information And (19397) Tremetrics Inc. (63409) | |
113S2 | 6630-00-143-6763 | Analyzer, Blood gas | Special Features: Design type:auxiliary unit constructed;scale RANGE:P10.0/P100.0 millimeters and P0.0/P800.0 millimeters;measuring method:manometric;electrical shaking device:not provided;auxiliary unit name and qty:constant temp BATH-1, electrode, hydrogen ion, GLASS-2, electrode assy, PCO2-2 assy, PO2-2, electrolyte, PCO-1 bottle, electrolyte, PO2-1 bottle, carbon dioxide- OXYGEN-1, nitrogen-carbon dioxide 1, parts kit, PCO2 MEMBRANE-1, parts kit PO2.MEMBRANE-1, std solution buffer, 6.84 PH-1 bottle, std solution buffer 7.384 PH-1 bottle REGULATOR-1, glass cylinder;used for micro determinations of ph PCO2 and PO2; Unit OF Issue Cube: 4.564 cubic feet Unit OF Issue Weight: 56.00 pounds | Instrumentation Laboratory Company (22270) | |
1140-004 1140004 | 6630-00-399-2976 | Connector, Gum Rubbe | Unicontrol Inc. (27847) | ||
1141AND1140A | 6630-00-935-6874 | Comparator, Color | Overall Width: 10.000 inches nominal Overall Height: 2.875 inches nominal Accessory Components AND Quantity: Base -1, slide comparator -1, color standards -9, rod, stirring, plastic -1, bottle, indicator solution -2, pipet, dropping W/rubber nipple, graduated at 0.5 ml -2, test tube, comparison 5 ml -5, sponge, cleaner -1, stopper, rubber -1 | Taylor Technologies Inc. (89975) | |
1142577 | 6630-01-328-2288 | Calibration kit, Clinical Chemist | General Characteristics Item Description: C/O 15 white plastic calibration strips with gray pad on the end for define reflectant value; used to verify the optical system of the reflotron analyzer P/N 747459; 16 prep pads 70% isopropanol; used to clean contaminated infectious material after every 100 tests or at least weekly for maximum performance; sufficient quantity to perform 15 tests Part Name Assigned BY Controlling Agency: Calibration kit clinical chemistry analyzer performs 15 tests | Roche Diagnostics Corporation (51169) | |
114400-3701 1144003701 | 6630-01-015-5935 | Detector, Electrolytic Conductivi | General Characteristics Item Description: Gas chromatographic technology type, ac bridge operation, selective response to chloride, nitrogen and sulfer | BAE Systems Information And (19397) Tremetrics Inc. (63409) | |
114400-4400/114400-1400/114400-- 11440044001144001400114400 | 6630-01-036-3279 | Chromatograph, gas | General Characteristics Item Description: Floor mtd oven, 1100 cu. in. capacity for operation with 4 U-shaped columns; temp control of 4 inlets and 4 outlets, pyrometer with 7 position selfctor switch, 2 panel mounts for detector gas metering modules, 4 carrier gas flow controllers and 9 in. rotameters, motor driven vent, removable doors, carrier gas filter drier kit, 2 test columns 6 ft. by 0.25 in., instruction manual, 110 vac, 50/60 hz; isothermal temp controller, ambient to 400 deg C, porm 0.1 deg c; dual flame ionization detector, max. carrier flow 200 cc/min, max. solvent volume 50 microliters, heater with controller, thermocouple, igniter, installation kit, 2 filter driers; dual solid state electrometer; dual flame and electron capture detector gas metering module Reference Number Differentiating Characteristics: As differentiated by detector, electrometer, and detector gas metering module Extra Long Reference Number: 114400-4400/114400-1400/114400-3102FF/114400-2206/114400-5205 | Tremetrics Inc. (63409) | |
1146 | 6630-01-080-8623 | Analyzer, Carbon Monoxide | General Characteristics Item Description: Portable; direct-reading; aluminum frame; full-scale range 0-50/0-100PPM; ac/dc; 105-125 vac; 50-60 hz; 184X152X292MM | Interscan Corporation (55099) | |
11493-33 1149333 | 6630-01-125-5385 | Lamp Assembly, Spect | Part Name Assigned BY Controlling Agency: Lamp assembly spect end item 6630-00-140-7826 END Item Identification: 6630-00-140-7826 | Hach Company (91224) | |
114-9764 1149764 | 6630-01-432-5905 | Clinical Chemistry Calibrator Ki | General Characteristics Item Description: Clinical chemistry calibrator kit no. 5; can be used for the 3 separate events; consists of ammonia (amon) and protein (prot).; use with nsn 6630-01-441-5297, vitrose 250 chemistry analyzer Part Name Assigned BY Controlling Agency: Calibrator kit clinical chemistry U/W vitros 250/950 4S | Ortho-Clinical Diagnostics Inc. (03KD1) | |
115000 | 6630-01-422-2096 | Central Data Station, Clinical An | General Characteristics Item Description: Consists of: cpu, keyboard, modem, mouse, cannon bubblejet printer, and cables Special Features: For use with hand held analyzers P/N 210000 nsn 6630-01-411-2405 and P/N 111000 nsn 6630-01-411-2568. use the following nsns for: infared (ir) link 6630-01-422-2095, simulator 6630-01-422-2097, portable printer 6630-01-422-2098, pinter cradle 6630-01-419-7887, pinter paper 6640-01-419-5698, capillary tube 6640-01-419-3519 and lithium battery 6135-01-421-7168. for A list of test cartridges use cage code 00WB2 on your medcat or fed log cd search (p/N to cage). Part Name Assigned BY Controlling Agency: Central data station clinical analyzer used W/handheld analyzer | I-Stat Corporation (00WB2) |