Chemical Analysis Instruments: 04-1275, 04-1325, 04-1623
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
04-1275 041275 | 6630-01-524-2507 | Jbaids T-Handle Driver | III End Item Identification: Biological agent detection syst., nsn: 6630-01-523-5629 III Part Name Assigned BY Controlling Agency: Driver T-handle 3-32 9IN. F/jbaids system Special Features: T-handle driver, 3-32, 9IN.; use for any necessary repairs and maintenance of instruments in the biological detection system, jbaids system | Defense Logistics Agency (89875) | |
04-1276 041276 | 6630-01-524-2513 | Jbaids Screwdriver Standard Driv | Overall Length: 5.50 inches nominal End Item Identification: Biological agent detection syst., nsn: 6630-01-523-5629 Handle Color: Black | Defense Logistics Agency (89875) | |
04-1277 041277 | 6630-01-524-2517 | Jbaids Nutdriver, Standard | III End Item Identification: Biological agent detection syst., nsn: 6630-01-523-5629 III Part Name Assigned BY Controlling Agency: Nutdriver standard 3/16IN.F/JBAIDS system 3IN. shaft Special Features: Standard nutdriver 3/16IN.; for any necessary repairs and maintenance of instruments in the biological detection system, jbaids system; has a 3 inch shaft | Defense Logistics Agency (89875) | |
04-1278 041278 | 6630-01-524-2522 | Jbaids Nutdriver Standard | Overall Length: 7.00 inches nominal Shaft Length: 3.25 inches nominal III End Item Identification: Biological agent detection syst., nsn: 6630-01-523-5629 | Defense Logistics Agency (89875) | |
04-1279 041279 | 6630-01-524-2547 | Threadlocker Adhesive, Jbaids | End Item Identification: Biological agent detetion system nsn: 6665-01-523-5629 Part Name Assigned BY Controlling Agency: Threadlocker adhesive loctite 222 F/jbaids system Special Features: Threadlocker adhesive, loctite 222; for necessary repairs and maintenance of instruments in the biological detection system, jbaids system | Defense Logistics Agency (89875) | |
04-1288 041288 | 6630-01-524-3128 | Cartridge, Ceramic for I-Stat | Special Features: Ceramic cartridge used to clean electrodes of I-stat blood chemistry analyzer E.I., nsn 6630-01-496-5195 Part Name Assigned BY Controlling Agency: Cartridge ceramic for I-stat blood chemistry analyzer E.I. nsn 6630-01-496-5195 | Defense Logistics Agency (89875) | |
04-1319 041319 | 6630-01-524-9882 | Chemical Identification System, a | Special Features: Includes the hapsite smart analytical module with neg pump installed, ship kit with battery charger, hand control unit (probe), ruggedized tough-book pc with nist library and hapsite smart software and servic module; fast, on-scene detection, identification and quantitation of toxic industrial chemicals and warfare agents Part Name Assigned BY Controlling Agency: Chemical id system hapsite smart analytical module | Defense Logistics Agency (89875) | |
04-1325 041325 | 6630-01-524-2968 | Bulb, Blood Sample Capillary Tube | Special Features: These bulbs fit micro capillary tubes of 1 ato 2MM O.D. Part Name Assigned BY Controlling Agency: Bulb blood sample capillary tube rubber black 8MM dia 15MM 1000S Overall Length: 15.000 millimeters nominal | Defense Logistics Agency (89875) | |
041-340 041340 | 6630-00-028-8379 | Cup, Sample, Automated Analysis | Primary Container Type: BOX Primary Container Unit Quantity: 1000 Style Designator: Round, flat bottom with conical base | Baxter Healthcare Corporation (04496) | |
04-1434 041434 | 6630-01-524-4220 | Analyzer, Clinical Chemistry | Special Features: Obench top immunoanalyzer; automated with walk-away capability; built-in calibration and controls; self-contained reagents; performs automated immuno-assays for hormones, therapeutic drugs, thyroid serologies, and miscellaneous chemistries; capable of holding 12 single reagent strips, 6 double reagent strips; assay dependent (1 to 2 hours typical); 1.5 AMPS/200/250 vac; 0.8 amps; shall be compatible with the following assays: clostridium difficile toxin-A test, nsn: 6650-01-524-4224; chlamydia antigen test, nsn: 6550-01-524-4227; chlamydia blocking test for confirmation of antigen, nsn: 6550-01-524-4228; helicobactor pylori test, nsn: 6550-01-524-4277; human chorionic gonadotropin (hcg) test, nsn: 6550-01-524-4287; digoxin test, nsn: 6650-01-524-4285; theophyllin test, nsn: 6550-01-524-4284; total prostate specific antigen (t-psa) test, nsn: 6550-01-524-4248; D-dimer test, nsn: 6550-01-524-4244; printer paper, NSN:6550-01-524-4257; bar code scanner, nsn: 6550-01-524-4249 Current Type: AC Voltage IN Volts: 100.0 and 130.0 | Defense Logistics Agency (89875) | |
04-1485 041485 | 6630-01-525-1231 | Analyzer, Blood Glucose | Special Features: Roche diagnostics accu-check inform blood glucose monitoring system; use to monitor blood glucose reading and provide recordkeeping for quality control of blood glucose results; stores up to 4, 000 measurements including time, date, valid operator id, patient id list, quality control pass/fail, mandatory comments, and critical range messages Part Name Assigned BY Controlling Agency: Analyzer blood glucose (1) per package | Defense Logistics Agency (89875) | |
04-1486 041486 | 6630-01-525-2999 | Base unit, Glucose Monitor | Special Features: For the accu-chek glucose monitor; functions as A charging system as well as A computer interfacing device;includes wall mount and screws, cable cord and adaptor Part Name Assigned BY Controlling Agency: Base unit-charger F/accu-chek inform glucose monitor | Defense Logistics Agency (89875) | |
04-1509 041509 | 6630-01-525-5554 | Tubing, Rinse, Analyzer, Hematology | Special Features: Replacement tubing for the rinse agent; this is part of the ac-T 10 pack; for use with the hematology analyzer Part Name Assigned BY Controlling Agency: Tubing rinse coulter act 10 (1) per package END Item Identification: For use with nsn 6630-01-468-9142, analyzer, hematology; for use with nsn 6630-01-490-6235; tainer T, diff ac | Defense Logistics Agency (89875) | |
04-1510 041510 | 6630-01-525-5553 | Tubing, Diluent, Analyyzer, Clinica | Special Features: Replacement tubing for the diluent; part of the ac-T 10 pack; used with the clinical chemistry analyzer Part Name Assigned BY Controlling Agency: Tubing diluent coulter act 10 (1) per package END Item Identification: For use with nsn 6630-01-415-1593, analyzer, clinical, chemistry; for use with nsn 6630-01-490-6235; tainer T, diff ac | Defense Logistics Agency (89875) | |
04-1511 041511 | 6630-01-525-5546 | Tubing, Lyse, Analyzer, Hematology | Special Features: Replacement tubing for lyse agent; straw-like tubing F/250 ml; part of the ac-T 10 pack; for use with the hematology analyzer Part Name Assigned BY Controlling Agency: Tubing lyse 250 ml coulter act 10 (1) per package END Item Identification: For use witn nsn 6630-01-468-9142, analyzer, hematology, for use with nsn 6630-01-490-6235; tainer T, diff ac | Defense Logistics Agency (89875) | |
04-1547 041547 | 6630-01-526-7377 | Analyzer, Blood gas | Special Features: Blood analyzer (i-stat one) W/hard case; package with start-up supplies; A field kit which includes the analyzer-one and, supplies: C/o: 6640-01-519-5698, motor system (pn md 10); 6630-01-526-4098, battery, rechargeable (pn 06F23-55); 6630-01-422-2097, simulator, quality control test (pn 06F11-01); 6630-01-526-4091, printer, portable (06F23-91); 6630-01-524-3128, cartridge, ceramic (pn 04J51-01); 6630-01-487-8551, guard, mechanical, drive (pn 6509E85-003); 6630-01-526-3620, downloader-recharger unit (pn 06F23-45); 6630-01-526-4102, carry case (pn 06F16-79); and 6135-01-421-7168, battery, nonrechargeable (pn 6F2126). Part Name Assigned BY Controlling Agency: I-stat 1 government field kit | Defense Logistics Agency (89875) | |
0416-0010 04160010 | 6630-01-054-4357 | Chromatograph, gas | General Characteristics Item Description: Wpressure available to column: 7000 psi, pressure with pulse control: 7000 psi, max. flow rate: 20 ml/min, flow rate/pressure capabilities- 0-4 ml/min at 7000 psi, method of flow rate setting: digital dial, flow rate precision plus or minus 5 pct, flow control method-flow feedback, pulsation controlmethod-flow feedback, max. solvent volumn before system refill: no limitation, solvent change TIME-2 min., pressure monitoring: digital readout: 10 psi resolution, overpressure control: 100-7000 psi | Spectra-Physics Inc. (21033) | |
04-1617 041617 | 6630-01-526-3620 | Downloader-Recharger unit, Analyz | Part Name Assigned BY Controlling Agency: Downloader/recharger F/I stat analyzer series 300 Special Features: Used to perform software downloads for new I-STAT-1 products, 300 series; only compatible with newer I-STAT-1 analyzer, nsn: 6630-01-520-5212, series 300 instrument | Defense Logistics Agency (89875) | |
04-1620 041620 | 6630-01-526-4091 | Printer, Analyzer, Portable | Part Name Assigned BY Controlling Agency: Printer portable F/I stat analyzer series 300 Special Features: Portable printer for new I-stat -1 product, 300 series; only compatible with newer I-STAT-1 analyzer, nsn: 6630-01-520-5212, series 300 instrument | Defense Logistics Agency (89875) | |
04-1623 041623 | 6630-01-526-4098 | Battery, Analyzer, Rechargeable | Part Name Assigned BY Controlling Agency: Battery 9-VOLT nimh rechargeable F/I-stat analyzer Special Features: Used for the new I-STAT-1 product series 300 only, nsn: 6630-01-520-5212 | Defense Logistics Agency (89875) |