Chemical Analysis Instruments: 03-2387, 037-2093-201, 038-240
MFG SKU | NSN | Item Name | Details | Manufacturer (CAGE) | RFQ |
---|---|---|---|---|---|
03-2387 032387 | 6630-01-517-8952 | Tips, Versa, Analyzer | Special Features: Versa tips for vitros chemistry analyzers; package of 1000 Part Name Assigned BY Controlling Agency: Vitros versa tips 1000S END Item Identification: Vitros 250 chemistry analyzer, NSN:6630-01-441-5297 | Defense Logistics Agency (89875) | |
03-2388 032388 | 6630-01-517-6603 | Adapter, Tube, Analyzer | Special Features: For use with sarstedt microvett cb 1000 capillary collection tubes Part Name Assigned BY Controlling Agency: Microcollection tube adapter END Item Identification: Vitros 250 chemistry analyzer, NSN:6630-01-441-5297 | Defense Logistics Agency (89875) | |
03-2389 032389 | 6630-01-517-6236 | Adapter, Sample cup, Analyzer | Special Features: For use with 0.5 and 2 milliter sample cups; helps the analyzer sample directly from sample collection tubes, in some cases Part Name Assigned BY Controlling Agency: Sample cup adapter 4S END Item Identification: Vitros 250 chemistry analyzer, NSN:6630-01-441-5297 | Defense Logistics Agency (89875) | |
03-2393 032393 | 6630-01-517-6606 | Adapter, Tube Height, Analyzer | Special Features: Height adapter; accommodates tubes of varying lengths; pkg. of 8 Part Name Assigned BY Controlling Agency: Tube height adapter 8S END Item Identification: Vitros 250 chemistry analyzer, NSN:6630-01-441-5297 | Defense Logistics Agency (89875) | |
03-2394 032394 | 6630-01-517-6616 | Tray, Diluent-Reagent, Clinical Ch | Special Features: For use with vitros chemistry analyzing system; part of the sample tray and handling for vitros 250 Part Name Assigned BY Controlling Agency: Diluent tray F/chemistry analyzer END Item Identification: Vitros 250 chemistry analyzer, NSN:6630-01-441-5297 | Defense Logistics Agency (89875) | |
032-A001-01 032A00101 | 6630-01-080-6778 | Detector, Electrochemical | General Characteristics Item Description: 23IN. L X 13IN. W X 8IN. H, includes operational control panel, plug-in signal board W/mode select panel, proportional temperature-controlled air bath controlled to porm 0.2 deg C, 20-TURN coil sample conditioner, debubbler and electrode carriage assembly | Bayer Corp. (59426) | |
033059-1 0330591 | 6630-01-478-5577 | Analyzer, Clinical Chemistry | Special Features: Compact size table top design; closed tube sampling minimizes risk from blood borne pathogens; positive sample and reagent id-no more specimen and reagent confusion with ace's on-board computer that identifies and tracks samples and reagents by lot number, expiration date, and amount of reagent remaining for an ultra-secure, worry-free system; on-board sample and reagent refrigeration-up to 40 separate test reagents may be stored so effects such as exposure to light and evaporation are kept to an absolute minimum; single proble handles all sample and reagent aspiration and dispense functions; new cuvette for each reaction eliminates chance of cross contamination; immediate stat interrupt; auto repeat and dilution; multi-tasking intelligent software offers individual profile, batch, or stat assays; complete on screen help, color coded prompts and built in self diagnostics that guide every step of the way Part Name Assigned BY Controlling Agency: Analyzer clin chem kinetic enzyme/rate test Method OF Analysis: Kinetic enzyme/rate test | Alfa Wassermann Inc. (1QY50) | |
0331-9100/0331-0006/0331-4004/0- 0331910003310006033140040 | 6630-01-063-7267 | Chromatograph, gas | General Characteristics Item Description: 117 vac, 50/60 hz, consists of 9 detectors, 1 amplifier, 1 control console, 1 column oven, oven capacity 10, 000 cm Reference Number Differentiating Characteristics: As differentiated by an extra long refeence number Extra Long Reference Number: 0331-9100/0331-0006/0331-4004/0331-3115/0331-8280/0331-2201/0331-1000/0332-0118 | Applied Biosystems LLC (46555) | |
0331-9730 03319730 | 6630-01-196-3501 | Chromatograph, gas | Applied Biosystems LLC (46555) | ||
03388-90001 0338890001 | 6630-01-112-0962 | Integrator, Chromatograph | General Characteristics Item Description: Dual channel, keyboard allows entry of up to 12 character names, up to 10 reference peaks may be designated during the calibration procedure, 32000 bytes of random access memory for storage of calibration methods and program, control of hp 7670 series automatic samplers, dimensions in cm of mainframe 44 H, 55 D, 37 W, dimensions in cm of terminal 18 H, 33 D, 38 W, weight ofmain frame 63 lbs, weight of terminal 13 lbs, power 120-220/240 V at 47-66HZ 600 va, operates between 5 deg C and 45 deg C, 0 to 95 percent humidity, battery power backup for 10 min | Agilent Technologies Inc. (14376) | |
03404 | 6630-00-612-9407 | Bridge, Conductivity | General Characteristics Item Description: Manually balanced, battery operated, bridge balance indicated on null meter- twelve position multiplier W/scale calibrated for six conductivity positions 0.1 micromho to 0.1 mho and for six resistance positions 100 ohms to 10 megohms- three manually adjustable digital readout dials to null instrument- solid state circuitry- includes three batteries | Barnstead Thermolyne Corporation (05852) | |
035395 | 6630-01-463-7320 | Column, Analytical | General Characteristics Item Description: Ionpac AS-5 anaylitical column Part Name Assigned BY Controlling Agency: Column analytical ionpac AS-5 | Dionex Corporation (21248) | |
03601-000-01 0360100001 | 6630-01-552-9810 | Tester, Flash point | Petroleum Analyzer Company LP (02BZ8) | ||
03617548/001 03617548001 | 6630-01-549-8104 | Urinometer | Roche Diagnostics Corporation (51169) | ||
03641-000-01 0364100001 | 6630-01-552-9805 | Tester, Flash point | Petroleum Analyzer Company LP (02BZ8) | ||
0367-01-2 0367012 | 6630-01-415-5894 | Water Sampling Test kit, Sodium N | Special Features: For use with diesel engine cooling water treatments; consists of reagent ampoules ("titrets") and valve assemblies for titrimetric determinations in water: ea ampule contains approx 1 ml liquid reagent; ea valve assy contains approx. 0.05 ml liquid reagent; titret components = 3 pct sulfuric acid, ceric sulfate 5 pct and deionized water 92 pct; valve assy components = ferrous sulfate, heptahydrate and 1 10-HPENANTHROLINE 1.5 pct max, diethylene glycol greater than 97 pct | Ashland Chemical Co. (0FUA8) | |
037-2093-201 0372093201 | 6630-01-416-2489 | Photodiode, Analyzer | Part Name Assigned BY Controlling Agency: Photodiode analyzer | Danam Electronics Inc. (0MMD8) Drew Scientific Inc. (1ESE4) | |
037-4000-002 0374000002 | 6630-01-468-1800 | Optical Sensor, Wash Block | Special Features: Slotted optical sensor END Item Identification: Excell automatic hematology analyzer models 10, 16, or 18 | Danam Electronics Inc. (0MMD8) Drew Scientific Inc. (1ESE4) | |
0380014 | 6630-01-472-5812 | Water Sampling Test kit, Alkalini | Ashland Chemical Co. (05BL0) | ||
038-240 038240 | 6630-01-164-6511 | Wash Solution, Automated Analyzer | General Characteristics Item Description: Concentrated liquid; ea 125 ml btl C/O isooctyl phenoxy polyethoxy ethanol, 2.0 gm/liter, mold inhibitor and deionized water; when diluted shall equal 500 ml; flush solution used to wash sample path between use; 6 per pkg END Item Identification: Blood gas analyzer, nsns 6630-01-063-2944 and 6630-01-120-8419 Unit OF Issue Cube: 0.011 cubic feet | Curtin Matheson Scientific Inc. (15481) |